Atellica CH Urine Albumin (UAlb)
Atellica CH Microalbumin (UAlb) Reagent
2manufacturers in China registered for this device type
1catalogue number
Who Else Makes It
Concentrated in Jilin (1), Hunan (1).
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Dirui Industrial Co., Ltd. | Changchun | Jilin | Contract manufacturer | 84 |
| AVE Science & Technology Co., Ltd. | Changsha | Hunan | Manufacturer | 22 |
Record
| Listed by | Siemens Healthcare Diagnostics Inc, United States |
|---|---|
| FDA product code | DCF |
| Device type | Albumin, Antigen, Antiserum, Control |
| Device class | Class 2 |
| Regulation | 21 CFR 866.5040 |
| Establishment | Contract manufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter |
| Premarket notification | Exempt |
| Record published | 2025-08-11 |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Single use | Yes |
| Label carries | lot or batch number, expiry date |
| Storage | Handling environment temperature 2 to 8 °C; Special storage condition: Keep away from light and heat; Do not freeze; Storage environment temperature 2 to 8 °C |
Catalogue Numbers
| Catalogue number | Size | Per pack | Status |
|---|---|---|---|
| 11537225 | 4 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Ortho | Ortho-Clinical Diagnostics, Inc. | 4 |
| JAS Diagnostics | Drew Scientific, Ltd. | 2 |
| N Antiserum to Human Albumin | Siemens Healthcare Diagnostics Products GmbH | 2 |
| AU | Beckman Coulter, Inc. | 2 |
| Albumin LiquiColor® | Stanbio Laboratory, L.P. | 1 |
| Microalbumin Assay | Sekisui Diagnostics, LLC | 1 |
| K-Assay® Microalbumin Reagent (L) | Kamiya Biomedical Company LLC | 1 |
| Human Albumin CSF Kit for use on Spaplus | The Binding Site Group Ltd. | 1 |
| Microalbuminuria Kit (Immunoturbidimetric Method) | Medicalsystem Biotechnology Co., Ltd. | 1 |
| Yumizen C1200 Albumin U/CSF | Horiba ABX SAS | 1 |
| Microalbumin | Sekisui Diagnostics, LLC | 1 |
| Synchron | Beckman Coulter, Inc. | 1 |
Showing 12 of 35. All products under Albumin, Antigen, Antiserum, Control
Recalls Naming This Product
2 recalls name this product by its own identifiers, the UDI on its label.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|---|---|
| Siemens Healthcare Diagnostics Inc | UDI-DI | 2026-07-06 | Class II | Under Investigation by firm | processing Atellica CH Urine Albumin (UAlb) tests on Atellica CH and Atellica CI analyzers may lead to the following issues: Falsely depressed Atellica CH Urea Nitrogen (UN_c) results; Falsely depressed Atellica CH Enzymatic Hemoglobin A1c | 7018 units |
| Siemens Healthcare Diagnostics Inc | UDI-DI | 2026-01-20 | Class II | Under Investigation by firm | Falsely depressed UAlb patient results may occur. Affected samples with any urine albumin concentration above the UAlb measuring interval >40.0 mg/dL may report values between 6.2 mg/dL and 40.0 mg/dL. | 4,885 units |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.