Cadwell Replacement Stimulator Probe
6 catalogue numbers from 360039-200, listed by Cadwell Industries, Inc., United States, under Stimulator, Electrical, Evoked Response. 3 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Shandong (1), Shaanxi (1), Guangdong (1). 3 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Shandong Weigao Orthopaedic Device Co., Ltd. | Weihai | Shandong | Contract manufacturer | 42 |
| Xian Friendship Medical Electronics Co., Ltd. | Xi’An | Shaanxi | Contract manufacturer | 10 |
| Shenzhen Launch Electrical Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 8 |
Record
| Listed by | Cadwell Industries, Inc., United States |
|---|---|
| FDA product code | GWF |
| Device type | Stimulator, Electrical, Evoked Response |
| Device class | Class 2 |
| Regulation | 21 CFR 882.1870 |
| Establishment | Specification developer, Manufacturer |
| Record published | 2016-09-05 |
| Record revised | 2024-01-11 (version 5) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Prescription | Prescription only |
| Latex | Labelled latex-free |
| Label carries | lot or batch number |
| Sizes | Outer diameter 0.181 to 0.31 in |
| UDI direct marking | Exempt |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 360039-200 | Outer Diameter 0.181 in | In distribution |
| 339080-200 | Outer Diameter 0.187 in | In distribution |
| 339079-200 | Outer Diameter 0.3 in | In distribution |
| 339084-200 | Outer Diameter 0.31 in | In distribution |
| 339073-200 | Outer Diameter 0.25 in | In distribution |
| 339078-200 | Outer Diameter 0.31 in | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Stimulator, Electrical, Evoked Response | Inomed Medizintechnik Gmbh | 170 |
| Alpine BioMed | Alpine Biomed Aps | 132 |
| Natus | Natus Neurology Incorporated | 98 |
| Keypoint | Natus Manufacturing Limited | 44 |
| Stimulator, Electrical, Evoked Response | Nihon Kohden America, Inc. | 41 |
| Stimulator, Electrical, Evoked Response | Nihon Kohden Corp. | 38 |
| Powerease™ Instruments | Medtronic Sofamor Danek, Inc. | 36 |
| Stimulator, Electrical, Evoked Response | Stryker Leibinger Gmbh & Co. KG | 29 |
| Natus | Xltek | 27 |
| Isis | Inomed Medizintechnik Gmbh | 26 |
| Xltek | Xltek | 24 |
| Natus Neurology | Natus Neurology Incorporated | 20 |
Showing 12 of 121. All products under Stimulator, Electrical, Evoked Response
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K230415 | 2023-08-17 |
| K162199 | 2017-03-02 |
Recalls
2 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|
| 2024-05-17 | Class II | Process design | Electroneurodiagnostic medical device may contain a defective printed circuit board which may cause damage to the other internal components resulting in unintended electrical stimulation. | 26 units |
| 2024-04-23 | Class II | Process design | There is the potential that an electroneurodiagnostic medical device insulator may be installed incorrectly which could result in arcing to patient connections resulting in potential unintended shock to the patient. | 54 units |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.