Cascade

ES5-20 Stim Splitter

Registry build 21.09.26
3manufacturers in China registered for this device type
1catalogue number
2510(k) clearances naming this product code
2recalls on this code

Who Else Makes It

Concentrated in Shandong (1), Shaanxi (1), Guangdong (1). 3 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code GWF
Manufacturer City Province Registered as Device types
Shandong Weigao Orthopaedic Device Co., Ltd. Weihai Shandong Contract manufacturer 42
Xian Friendship Medical Electronics Co., Ltd. Xi’An Shaanxi Contract manufacturer 10
Shenzhen Launch Electrical Co., Ltd. Shenzhen Guangdong Contract manufacturer 8

Record

Regulatory record for Cascade
Listed by Cadwell Industries, Inc., United States
FDA product code GWF
Device type Stimulator, Electrical, Evoked Response
Device class Class 2
Regulation 21 CFR 882.1870
Establishment Specification developer, Manufacturer
Record published 2016-09-05
Record revised 2025-12-31 (version 6)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Prescription Prescription only
Label carries serial number
Distribution end date 2025-12-31
UDI direct marking Exempt

Catalogue Numbers

Catalogue numbers for Cascade
Catalogue number Size Status
190204-200 Withdrawn

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Stimulator, Electrical, Evoked Response Inomed Medizintechnik Gmbh 170
Alpine BioMed Alpine Biomed Aps 132
Natus Natus Neurology Incorporated 98
Keypoint Natus Manufacturing Limited 44
Stimulator, Electrical, Evoked Response Nihon Kohden America, Inc. 41
Stimulator, Electrical, Evoked Response Nihon Kohden Corp. 38
Powerease™ Instruments Medtronic Sofamor Danek, Inc. 36
Stimulator, Electrical, Evoked Response Stryker Leibinger Gmbh & Co. KG 29
Natus Xltek 27
Isis Inomed Medizintechnik Gmbh 26
Xltek Xltek 24
Natus Neurology Natus Neurology Incorporated 20

Showing 12 of 121. All products under Stimulator, Electrical, Evoked Response

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K230415 2023-08-17
K162199 2017-03-02

Recalls

2 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity
2024-05-17 Class II Process design Electroneurodiagnostic medical device may contain a defective printed circuit board which may cause damage to the other internal components resulting in unintended electrical stimulation. 26 units
2024-04-23 Class II Process design There is the potential that an electroneurodiagnostic medical device insulator may be installed incorrectly which could result in arcing to patient connections resulting in potential unintended shock to the patient. 54 units

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.