Neuro-IOM
Neuro-IOM system with Neuro-IOM.NET software is a medical device intended for intraoperative neurophysiologic monitoring: the device provides information to assess a patient’s…
Neuro-IOM system with Neuro-IOM.NET software is a medical device intended for intraoperative neurophysiologic monitoring: the device provides information to assess a patient’s neurophysiological status. The system allows to monitor the functional integrity and/or mapping of central and peripheral nervous system including motor and sensory pathways. It is provided in III different configurations: I. 32/B II. 32/S III. 16/S The system ensures the following IOM modalities: free-run EMG (electromyography), direct nerve stimulation including pedicle screw test, SSEP (somatosensory evoked potentials), MEP (motor evoked potentials), EEG (electroencephalography), AEP (au-ditory evoked potentials), VEP (visual evoked potentials), direct cortical stimulation. Also the train-of-four (TOF) stimulation is performed. The system is not intended to measure the vital signs. It records the data to be inter-preted by the neuromonitoring specialist.
Who Else Makes It
Concentrated in Shandong (1), Shaanxi (1), Guangdong (1). 3 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Shandong Weigao Orthopaedic Device Co., Ltd. | Weihai | Shandong | Contract manufacturer | 42 |
| Xian Friendship Medical Electronics Co., Ltd. | Xi’An | Shaanxi | Contract manufacturer | 10 |
| Shenzhen Launch Electrical Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 8 |
Record
| Listed by | Neurosoft, OOO |
|---|---|
| FDA product code | GWF |
| Device type | Stimulator, Electrical, Evoked Response |
| Device class | Class 2 |
| Regulation | 21 CFR 882.1870 |
| 510(k) | K190703 |
| Record published | 2021-06-10 |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Prescription | Prescription only |
| Label carries | manufacturing date, serial number |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| Neuro-IOM | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Stimulator, Electrical, Evoked Response | Inomed Medizintechnik Gmbh | 170 |
| Alpine BioMed | Alpine Biomed Aps | 132 |
| Natus | Natus Neurology Incorporated | 98 |
| Keypoint | Natus Manufacturing Limited | 44 |
| Stimulator, Electrical, Evoked Response | Nihon Kohden America, Inc. | 41 |
| Stimulator, Electrical, Evoked Response | Nihon Kohden Corp. | 38 |
| Powerease™ Instruments | Medtronic Sofamor Danek, Inc. | 36 |
| Stimulator, Electrical, Evoked Response | Stryker Leibinger Gmbh & Co. KG | 29 |
| Natus | Xltek | 27 |
| Isis | Inomed Medizintechnik Gmbh | 26 |
| Xltek | Xltek | 24 |
| Natus Neurology | Natus Neurology Incorporated | 20 |
Showing 12 of 121. All products under Stimulator, Electrical, Evoked Response
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.