Sophysa
TEMPERATURE PATIENT MONITOR CABLE / HELLIGE, DATEX-OHMEDA, NIHON KOHDEN, MINDRAY & DATASCOPE- JACK 6,35 mm
Who Else Makes It
Concentrated in Guangdong (3), Shanghai (2). 3 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Shanghai Medical Instruments (Group) Ltd. Corp. | Shanghai | Shanghai | Contract manufacturer | 235 |
| Amphenol Alden Products Company | Shenzhen | Guangdong | Contract manufacturer | 24 |
| PAN-International Precision Electronic Co., Ltd. | Dongguan | Guangdong | Contract manufacturer | 4 |
| Shenzhen Mindray BIO-Medical Electronics Co., Ltd. | Shenzhen | Guangdong | Specification developer | 61 |
| Shanghai Wilpower Industrial Co., Ltd. | Shanghai | Shanghai | Exporter | 33 |
Record
| Listed by | Sophysa, France |
|---|---|
| FDA product code | GWM |
| Device type | Device, Monitoring, Intracranial Pressure |
| Device class | Class 2 |
| Regulation | 21 CFR 882.1620 |
| Establishment | Manufacturer |
| 510(k) | K062584 |
| Record published | 2017-07-25 |
| Record revised | 2023-05-18 (version 6) |
Specifications
| MRI safety | MR Unsafe |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date, manufacturing date, serial number |
| Distribution end date | 2026-07-03 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| PSO-4000 | In distribution | |
| PSO-MCT-A | In distribution | |
| PSO-MC01 | In distribution | |
| PSO-MCT-F | In distribution | |
| PSO-VT | In distribution | |
| PSO-PT | In distribution | |
| PSO-MCT-B | In distribution | |
| PSO-MC04 | In distribution | |
| PSO-MC05 | In distribution | |
| PSO-VTT | In distribution | |
| PSO-MC02 | In distribution | |
| PSO-PTT | In distribution | |
| PSO-PB | In distribution | |
| PSO-VTT | In distribution | |
| PSO-MCT-C | In distribution | |
| PSO-MRI | In distribution | |
| PSO-PBT | In distribution | |
| PSO-VT | In distribution | |
| PSO-MCT-E | In distribution | |
| PSO-MC08 | In distribution | |
| PSO-MC03 | In distribution | |
| PSO-EC30 | In distribution | |
| PSO-EC20 | In distribution | |
| PSO-VTT | In distribution | |
| PSO-MC06 | Withdrawn | |
| PSO-IN00 | Withdrawn | |
| PSO-PTT | Withdrawn | |
| PSO-MC10 | Withdrawn | |
| PSO-3000 | Withdrawn | |
| PSO-PBT | Withdrawn | |
| PSO-TX00 | Withdrawn | |
| PSO-MC07 | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Licox® | GMS, Gesellschaft für medizinische Sondentechnik mbH | 38 |
| Becker® | Medtronic PS Medical | 31 |
| Codman | Cerenovus, Inc. | 29 |
| Device, Monitoring, Intracranial Pressure | Medtronic PS Medical | 28 |
| Exacta™ | Medtronic PS Medical | 28 |
| Braincare | Braincare Desenvolvimento E Inovacao Tecnologica SA | 24 |
| Camino® | Integra Lifesciences (Ireland) Limited | 20 |
| Codman® | Integra LifeSciences Production Corporation | 19 |
| Integra® | Integra Lifesciences (Ireland) Limited | 17 |
| Aura | Branchpoint & Aura Development LLC | 17 |
| Natus | Natus Medical Incorporated | 15 |
| Duet® | Medtronic PS Medical | 14 |
Showing 12 of 133. All products under Device, Monitoring, Intracranial Pressure
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K252241 | 2026-04-10 |
| K162108 | 2017-04-17 |
| K062584 | 2007-07-05 |
Recalls Naming This Product
3 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|---|---|
| Sophysa | 510(k) number | 2025-11-17 | Class II | Software design | Customer complaints of Pressio monitor rebooting. | 105 units |
| Sophysa | 510(k) number | 2024-04-09 | Class II | Process change control | An increase in claims related to leakage of cerebrospinal fluid (CSF) from the proximal end of the catheter. In the event of a leak going undetected during implantation, it could pose an infectious risk to the patient. The cause of the leak | 3487 units OUS |
| Sophysa | 510(k) number | 2024-04-09 | Class II | Process change control | An increase in claims related to leakage of cerebrospinal fluid (CSF) from the proximal end of the catheter. In the event of a leak going undetected during implantation, it could pose an infectious risk to the patient. The cause of the leak | 3175 units- 41 units US; 3134 units OUS |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.