iSyncWaveTM is a wireless EEG measurement device that applies dry EEG measurement technology to an international 10-20 system compliant size-adjustable headset. iSyncWaveTM measures 19…
iSyncWaveTM is a wireless EEG measurement device that applies dry EEG measurement technology to an international 10-20 system compliant size-adjustable headset. iSyncWaveTM measures 19 channel EEG in real time and transfers the data through BLE wireless connection to the iSyncWaveTM App. The data is displayed and recorded via the iSyncWaveTM App. iSyncWaveTM uses dry electrode technology, which doesn’t require a preparation process(e.g., applying conductive gel), to obtain high quality EEG signals. Before measuring the EEG, you can check the impedance of each electrode under the impedance check screen in the iSyncWaveTM app. An EEG amplifier, analog-to-digital converter and Bluetooth are built in the device. All EEG signal is sampled at 250 Hz and then converted to digital data at 24-bit resolution. This device measures overall EEG data using 19 EEG electrodes, 1 Reference cable and 1 ground electrode. The measured data can be digitally converted to common average, longitudinal and transverse montage. The measured data is automatically uploaded to a secure cloud server via Wi-Fi connection and saved securely. The data saved in the cloud server can be seen on the iSyncWaveTM app. iSyncWaveTM can be only used by professional and/or medical personnel with product training and experience in EEG measurement. The professional and/or medical personnel can check the signal quality in real time and refer to the measured data in clinical practice.
Who Else Makes It
Concentrated in Guangdong (1), Jiangsu (1), Shaanxi (1). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
Record
Regulatory record for iSyncWave | Listed by | Imedisync Inc., South Korea |
| FDA product code | GWQ |
| Device type | Full-Montage Standard Electroencephalograph |
| Device class | Class 2 |
| Regulation | 21 CFR 882.1400 |
| Establishment | Manufacturer |
| 510(k) | K220056 |
| Record published | 2022-08-25 |
| Record revised | 2022-11-28 (version 2) |
Specifications
Specifications | MRI safety | MR Unsafe |
| Prescription | Prescription only |
| Label carries | manufacturing date, serial number |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.