Dome Electrodes
The Dome Electrode is a skin-surface electrode used with electromyography recording or monitoring equipment. It passively conducts the body’s electrical signals from the skin to compatible…
The Dome Electrode is a skin-surface electrode used with electromyography recording or monitoring equipment. It passively conducts the body’s electrical signals from the skin to compatible equipment without penetrating the skin.
Its rounded contact surface is made from 316L stainless steel. A threaded stud connects the electrode to an electrical conductor, and a nut with flat and locking washers secures that connection.
Interface Dimensions
The electrode has a diameter of 9.525 mm and a size 4-40 threaded connection. It is an accessory for compatible EMG equipment, which performs the recording and monitoring functions.
Who Else Makes It
Concentrated in Guangdong (29), Jiangsu (4), Zhejiang (4). 7 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Amphenol Medical Technologies (Dongguan) Co., Ltd. | Dongguan | Guangdong | Contract manufacturer | 77 |
| Shenzhen Konmed Technology Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 8 |
| China Qingdao Bright Medical Manufacturing Co., Ltd. | Qingdao | Shandong | Contract manufacturer | 8 |
| Pine Moon Electronics Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 8 |
| Top-rank Health Care Co., Ltd. | Shaoxing | Zhejiang | Contract manufacturer | 7 |
| Omron (Dalian) Co., Ltd. (Plant 1) | Dalian | Liaoning | Contract manufacturer | 7 |
| Shenzhen Zifound Infonet Technology Co., Ltd. | Shenzhen, Guandong | Guangdong | Contract manufacturer | 2 |
| Shenzhen Mindray BIO-Medical Electronics Co., Ltd. | Shenzhen | Guangdong | Specification developer | 61 |
| GE Medical Systems (China) Co., Ltd. | Wuxi | Jiangsu | Contract manufacturer | 57 |
| Edan Instruments, Inc. | Shenzhen | Guangdong | Contract manufacturer | 56 |
| Beijing Choice Electronic Technololgy Co., Ltd. | Beijing | Beijing | Repacker / relabeller | 30 |
| Taizhou Chenguang Import AND Export Trading Co., Ltd. | Taizhou | Jiangsu | Exporter | 25 |
Showing 12 of 47. All 47 manufacturers in China registered for Electrode, Cutaneous
Record
| Listed by | Coapt LLC, United States |
|---|---|
| FDA product code | GXY |
| Device type | Electrode, Cutaneous |
| Device class | Class 2 |
| Regulation | 21 CFR 882.1320 |
| Establishment | Remanufacturer, Complaint-file establishment, Manufacturer |
| 510(k) | K190416 |
| Record published | 2019-04-15 |
| Record revised | 2023-12-18 (version 2) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Prescription | Prescription only |
| Label carries | manufacturing date, serial number |
Catalogue Numbers
| Catalogue number | Size | Per pack | Status |
|---|---|---|---|
| 1 | 18 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Rhythmlink® | Rhythmlink International, LLC | 455 |
| waveguard | Eemagine Medical Imaging Solutions Gmbh | 166 |
| Espire Elbow Hybrid | College Park Industries | 138 |
| Technomed Europe | Technomed Engineering B.V. | 126 |
| Cadwell | Technomed Engineering B.V. | 111 |
| The Electrode Store | Impulse Technology LLC | 109 |
| Electrode, Cutaneous | Gmdasz Manufacturing Co., Ltd. | 99 |
| Auvon | Shenzhen Yuwen E-Commerce Co., Ltd. | 93 |
| AdvanTrode | Pepin Manufacturing, Inc. | 78 |
| Uni-Patch | Cardinal Health | 77 |
| Alpha | WillowWood Global LLC | 68 |
| Espire Elbow Pro | College Park Industries | 67 |
Showing 12 of 1,006. All products under Electrode, Cutaneous
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K223738 | 2023-01-11 |
| K223605 | 2022-12-30 |
| K191083 | 2019-05-24 |
| K190416 | 2019-04-04 |
| K162891 | 2017-04-14 |
Recalls Naming This Product
1 recall names this product by its own identifier, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|---|---|
| Coapt LLC | 510(k) number | 2023-10-02 | Class II | Process design | Patient may experience minor burn or blistering if device is exposed to direct sunlight and/or warm temperatures for over 12 hours or battery is damaged. | 247 devices |
Recalls
1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|
| 2023-10-02 | Class II | Process design | Patient may experience minor burn or blistering if device is exposed to direct sunlight and/or warm temperatures for over 12 hours or battery is damaged. | 109 devices |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.