Multigen 2
200MM Electrode
Who Else Makes It
Concentrated in Guangdong (1), Shanghai (1). One is registered as a contract manufacturer, able to build to a specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Amphenol Alden Products Company | Shenzhen | Guangdong | Contract manufacturer | 24 |
| Cathay Manufacturing Corp. | Shanghai | Shanghai | Contract manufacturer | 5 |
Record
| Listed by | Stryker GmbH, Switzerland |
|---|---|
| FDA product code | GXD |
| Device type | Generator, Lesion, Radiofrequency |
| Device class | Class 2 |
| Regulation | 21 CFR 882.4400 |
| Establishment | Contract manufacturer, Specification developer, Complaint-file establishment, Manufacturer |
| Record published | 2017-06-15 |
| Record revised | 2024-05-06 (version 4) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Sterilisation | Moist Heat or Steam Sterilization |
| Prescription | Prescription only |
| Label carries | manufacturing date, serial number |
| Storage | Storage environment temperature -34 to 65 °C |
| Sizes | Length 50 to 200 mm |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 8400-815-020 | Length 200.0 mm | In distribution |
| 8400-815-010 | Length 100.0 mm | In distribution |
| 8400-815-005 | Length 50.0 mm | In distribution |
| 8400-815-015 | Length 150.0 mm | In distribution |
| 8400-800-000 | In distribution | |
| 8400-000-000 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Generator, Lesion, Radiofrequency | Boston Scientific Neuromodulation Corporation | 68 |
| Generator, Lesion, Radiofrequency | Stryker Leibinger Gmbh & Co. KG | 58 |
| OneRF Ablation System | Neuroone Medical Technologies Corp. | 7 |
| GX1™ | Boston Scientific Neuromodulation Corporation | 7 |
| Accurian | Medtronic Sofamor Danek, Inc. | 7 |
| Avanos* | Avanos Medical, Inc. | 4 |
| OWL | Diros Technology, Inc. | 4 |
| NeuroTherm™ | Neurotherm, Inc. | 3 |
| Halyard | Avanos Medical, Inc. | 3 |
| Venom Multigen 2 | Stryker GmbH | 2 |
| Relievant | Relievant Medsystems | 2 |
| IonicRF™ | St. Jude Medical | 2 |
Showing 12 of 26. All products under Generator, Lesion, Radiofrequency
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K170242 | 2017-05-25 |
Recalls
1 of these is Class III. Class III is unlikely to cause harm at all → typically a labelling or documentation fault. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2016-10-11 | Class III | Labeling Change Control | Stryker Instruments is voluntarily recalling the Care Instructions/Instructions for Use packaged with the Radiofrequency (RF) MultiGen Generator, because the instructions for use incorrectly contained instructions supporting the sterilizati | 2,675 | 2017-07-25 |
| 2010-04-13 | Not classified | Component design/selection | This recall is related to the Electri-cord recall. There is a risk when excessive force is applied to the plugs, a fracture can develop on the prongs inside the molded section of the plug. Over time the fracture may lead to arcing inside o | 3364 all products | 2011-05-16 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.