SideKick™ 2

Siliconized 15cm x 10mm x 18ga (1.2mm)

Registry build 21.09.26
1manufacturer
4catalogue numbers in this listing
9recalls on this code

Who Else Makes It

Registered in Guangdong. One is registered as a contract manufacturer, able to build to a specification.

Chinese manufacturers registered for FDA product code GXI
Manufacturer City Province Registered as Device types
Amphenol Alden Products Company Shenzhen Guangdong Contract manufacturer 24

Record

Regulatory record for SideKick™ 2
Listed by Boston Scientific Neuromodulation Corporation, United States
FDA product code GXI
Device type Probe, Radiofrequency Lesion
Device class Class 2
Regulation 21 CFR 882.4725
Establishment Specification developer, Complaint-file establishment, Manufacturer
Record published 2021-04-28

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date
Packaging Pack of 10

Catalogue Numbers

Catalogue numbers for SideKick™ 2
Catalogue number Size Status
RFK-C151018S-ZK2 15cm x 10mm x 18ga (1.2mm) In distribution
RFK-C101018S-ZK2 10cm x 10mm x 18ga (1.2mm) In distribution
RFK-C101020S-ZK2 10cm x 10mm x 20ga (0.9mm) In distribution
RFK-C151020S-ZK2 15cm x 10mm x 20ga (0.9mm) In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
OWL Diros Technology, Inc. 345
Probe, Radiofrequency Lesion Boston Scientific Neuromodulation Corporation 175
Halyard Avanos Medical, Inc. 156
Lccs Lccs Products Limited 101
Epimed Epimed International, Inc. 100
Avanos Avanos Medical, Inc. 89
NeuroTherm™ Neurotherm, Inc. 87
Probe, Radiofrequency Lesion St. Jude Medical 66
cannulaRFK Cosman Medical, Inc. 56
Rftl Pajunk Gmbh Medizintechnologie 54
Radiofrequency (RF) Needle Spectra Medical Devices, LLC 49
cannulaCC Cosman Medical, Inc. 47

Showing 12 of 85. All products under Probe, Radiofrequency Lesion

Recalls

9 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2026-04-29 Class II Under Investigation by firm Reusable electrodes may not meet expected performance levels. 49,251 units
2026-04-29 Class II Under Investigation by firm Reusable electrodes may not meet expected performance levels. 31,923 units
2026-04-22 Class II Packaging process control Intraosseous nerve ablation system instruments may have sterile barrier breach of the outer tray seal, which may introduce a risk of sterility breach, and if breached could lead to severe infection. 37,764
2019-05-30 Class II Error in labeling The firm initiated a voluntary correction of certain Cosman TCN Electrodes due to an incorrect revision of the Instructions for Use (IFU) being packaged with these products. 43 units 2021-04-28
2019-05-30 Class II Error in labeling The firm initiated a voluntary correction of certain Cosman TCN Electrodes due to an incorrect revision of the Instructions for Use (IFU) being packaged with these products. 437 units 2021-04-28
2019-05-30 Class II Error in labeling The firm initiated a voluntary correction of certain Cosman TCN Electrodes due to an incorrect revision of the Instructions for Use (IFU) being packaged with these products. 118 units 2021-04-28
2019-05-30 Class II Error in labeling The firm initiated a voluntary correction of certain Cosman TCN Electrodes due to an incorrect revision of the Instructions for Use (IFU) being packaged with these products. 110 units 2021-04-28
2019-05-30 Class II Error in labeling The firm initiated a voluntary correction of certain Cosman TCN Electrodes due to an incorrect revision of the Instructions for Use (IFU) being packaged with these products. 40 units 2021-04-28
2017-07-05 Class II Device Design After multiple reprocessing cycles, the epoxy resin which holds the TCN Electrode in the hub can exhibit signs of damage. In some cases, this damage may result in the inability to fully remove blood and/or tissue residuals prior to cleaning 11250 units (10,460 USA; 790 OUS) 2018-09-14

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.