Microtargeting™ Electrode and Insertion Tube Kit
microTargeting STar Array Electrode and Insertion Tube Kit, 5x, for use with Stereotactic Frame and STar Drive. Contains: IT(AR16): Insertion Tube. IT(AR17): Insertion Tube w/ Stylet.…
microTargeting STar Array Electrode and Insertion Tube Kit, 5x, for use with Stereotactic Frame and STar Drive. Contains: IT(AR16): Insertion Tube. IT(AR17): Insertion Tube w/ Stylet. MTDWLN(AR)(AR2): microTargeting Electrode. 66-CN-ET: Insertion Tube Extractor. Individual Specifications: IT(AR16) – 135mm tube length, 1.981mm OD, 0.96mm ID. IT(AR17) – 243.5mm tube length, 0.902mm OD, 0.597mm ID, 264mm stylet length (includes collar). MTDWLN(AR)(AR2) – 276.5mm electrode length, 10mm differential, 261.5mm protective tube length, 0.55mm OD. DZAP(L) 1 Meg
Who Else Makes It
Concentrated in Shanghai (2), Shandong (1), Beijing (1).
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Shanghai Medical Instruments (Group) Ltd. Corp. | Shanghai | Shanghai | Contract manufacturer | 235 |
| Xinhua Surgical Instrument Co., Ltd. | Zibo | Shandong | Manufacturer | 222 |
| Shanghai Wilpower Industrial Co., Ltd. | Shanghai | Shanghai | Exporter | 33 |
| Hotry Co., Ltd. | Beijing | Beijing | Manufacturer | 9 |
Record
| Listed by | FHC, Inc., United States |
|---|---|
| FDA product code | HAO |
| Device type | Instrument, Surgical, Non-Powered |
| Device class | Class 1 |
| Regulation | 21 CFR 882.4535 |
| Establishment | Complaint-file establishment, Manufacturer |
| Record published | 2016-08-22 |
| Record revised | 2023-01-10 (version 5) |
Specifications
| MRI safety | MR Unsafe |
|---|---|
| Sterilisation | Ethylene Oxide, Moist Heat or Steam Sterilization |
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date |
| Storage | Handling environment humidity 0 to 95 % RH; Storage environment temperature 0 to 40 °C; Storage environment humidity 0 to 95 % RH |
| Distribution end date | 2023-01-10 |
Catalogue Numbers
| Catalogue number | Size | Per pack | Status |
|---|---|---|---|
| KTF1002-00134 | 5 | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Integra® Ruggles®-Redmond™ | Integra LifeSciences Production Corporation | 705 |
| Ambler Surgical | Ambler Surgical, LLC | 597 |
| V. Mueller | Steris Corporation | 577 |
| Millennium | Avalign Technologies, Inc. | 383 |
| Avalign | Avalign Technologies, Inc. | 352 |
| Novo Surgical | Novo Surgical, Inc. | 300 |
| Novo Surgical Inc. | Novo Surgical, Inc. | 283 |
| Boss Instruments | Boss Instruments, Ltd. | 263 |
| Pilling | Teleflex Medical LLC | 156 |
| Instrument, Surgical, Non-Powered | Karl Storz GmbH & Co. KG | 130 |
| Instrument, Surgical, Non-Powered | Fehling Instruments GmbH | 126 |
| Integra® Jarit® | Integra LifeSciences Production Corporation | 109 |
Showing 12 of 249. All products under Instrument, Surgical, Non-Powered