Achievecas
Achievecas Reflection Passive Spheres 4 Quantity 1 Pack Sterile
Who Else Makes It
Concentrated in Jiangsu (2), Shanghai (1), Shandong (1). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Paragon Medical Device (Changzhou) Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 53 |
| Shandong Weigao Orthopaedic Device Co., Ltd. | Weihai | Shandong | Contract manufacturer | 42 |
| Zimmer (Shanghai) Medical International Trading Co., Ltd. | Shanghai | Shanghai | Exporter | 106 |
| Medtronic (Changzhou) Medical Devices Technology Co., Ltd. | Changzhou | Jiangsu | Manufacturer | 53 |
| Sinovation (Beijing) Medical Technology Co., Ltd. | Beijing | Beijing | Manufacturer | 1 |
Record
| Listed by | Smith & Nephew, Inc., United States |
|---|---|
| FDA product code | HAW |
| Device type | Neurological Stereotaxic Instrument |
| Device class | Class 2 |
| Regulation | 21 CFR 882.4560 |
| Establishment | Contract manufacturer, Remanufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter |
| 510(k) | K033341 |
| Record published | 2015-08-29 |
| Record revised | 2023-10-04 (version 9) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Sterilisation | Moist Heat or Steam Sterilization |
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date |
| Distribution end date | 2023-10-04 |
Catalogue Numbers
| Catalogue number | Size | Per pack | Status |
|---|---|---|---|
| 74452322 | In distribution | ||
| 74451117 | In distribution | ||
| 74452313 | In distribution | ||
| 74471206 | In distribution | ||
| 74473200 | In distribution | ||
| 74451007 | In distribution | ||
| 74452314 | In distribution | ||
| 74471201 | Withdrawn | ||
| 74451009 | Withdrawn | ||
| 74452005 | Withdrawn | ||
| 74452332 | Withdrawn | ||
| 74452317 | Withdrawn | ||
| 74453002 | Withdrawn | ||
| 74452310 | Withdrawn | ||
| 74452318 | Withdrawn | ||
| 74451224 | Withdrawn | ||
| 74452003 | Withdrawn | ||
| 74452334 | Withdrawn | ||
| 74453001 | Withdrawn | ||
| 74451223 | Withdrawn | ||
| 74452001 | Withdrawn | ||
| 74471203 | Withdrawn | ||
| 74452308 | Withdrawn | ||
| 74451119 | Withdrawn | ||
| 74451008 | Withdrawn | ||
| 74451006 | Withdrawn | ||
| 74471202 | Withdrawn | ||
| 74471205 | Withdrawn | ||
| 74452330 | Withdrawn | ||
| 71470901 | Withdrawn | ||
| 74452338 | Withdrawn | ||
| 74452331 | Withdrawn | ||
| 74451221 | Withdrawn | ||
| 74452301 | Withdrawn | ||
| 74451226 | Withdrawn | ||
| 74452339 | Withdrawn | ||
| 74451511 | Withdrawn | ||
| 74453003 | Withdrawn | ||
| 74452319 | Withdrawn | ||
| 74452341 | Withdrawn | ||
| 74482004 | 4 | Withdrawn | |
| 74451018 | Withdrawn | ||
| 74452307 | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Neurological Stereotaxic Instrument | Medtronic Navigation, Inc. | 844 |
| PMT Corporation – Stereotactic | PMT Corp. | 255 |
| Leksell Stereotactic System | Elekta Instrument AB | 199 |
| Neurological Stereotaxic Instrument | Inomed Medizintechnik Gmbh | 146 |
| Neurological Stereotaxic Instrument | Stryker Leibinger Gmbh & Co. KG | 125 |
| Geniant Cranial | KOH Young Technology Inc. | 113 |
| CRW® | Integra Lifesciences Corporation | 107 |
| Leksell Stereotactic System | Elekta Solutions AB | 93 |
| microTargeting™ Insertion Tube with Stylet | FHC, Inc. | 60 |
| Leksell Stereotactic System Neurosurgical Instruments | Elekta Instrument AB | 58 |
| Leksell Vantage Stereotactic System | Elekta Instrument AB | 53 |
| Stealth Autoguide™ System | Medtronic Navigation, Inc. | 50 |
Showing 12 of 1,137. All products under Neurological Stereotaxic Instrument
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K083565 | 2009-02-20 |
| K082267 | 2008-10-29 |
| K080875 | 2008-07-18 |
| K033341 | 2004-09-10 |
| K021798 | 2002-12-09 |
| K021815 | 2002-10-17 |
| K022460 | 2002-08-19 |
| K012938 | 2002-02-08 |
Recalls Naming This Product
1 recall names this product by its own identifier, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Zimmer, Inc. | 510(k) number | 2006-04-27 | Not classified | Device Design | The three-point array may break during use, resulting in surgical delay and an increased risk of infection. | 239 | 2009-03-11 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.