BrightMatter Pointer

The BrightMatter Pointer is a handheld instrument for palpating anatomy and pointing to locations during image guided cranial surgery. It works with the BrightMatter Guide navigation…

Registry build 21.09.26

The BrightMatter Pointer is a handheld instrument for palpating anatomy and pointing to locations during image guided cranial surgery. It works with the BrightMatter Guide navigation system, which identifies and tracks the pointer. It is intended for trained surgeons and clinical staff using that compatible system.

Passive reflective spheres attach to rigid features on the pointer. Their arrangement forms a distinct pattern that lets the navigation system recognize the instrument and determine its position from reflected infrared signals. The tip provides the physical point used for palpation and localization.

Reprocessing

The pointer is reusable and supplied nonsterile, requiring steam sterilization before use. The attached passive reflective markers are single use components. These processing requirements apply separately to the instrument and its markers.

5manufacturers in China registered for this device type
1catalogue number
4510(k) clearances naming this product code
2recalls on this code

Who Else Makes It

Concentrated in Jiangsu (2), Shanghai (1), Shandong (1). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code HAW
Manufacturer City Province Registered as Device types
Paragon Medical Device (Changzhou) Co., Ltd. Changzhou Jiangsu Contract manufacturer 53
Shandong Weigao Orthopaedic Device Co., Ltd. Weihai Shandong Contract manufacturer 42
Zimmer (Shanghai) Medical International Trading Co., Ltd. Shanghai Shanghai Exporter 106
Medtronic (Changzhou) Medical Devices Technology Co., Ltd. Changzhou Jiangsu Manufacturer 53
Sinovation (Beijing) Medical Technology Co., Ltd. Beijing Beijing Manufacturer 1

Record

Regulatory record for BrightMatter Pointer
Listed by Synaptive Medical Inc, Canada
FDA product code HAW
Device type Neurological Stereotaxic Instrument
Device class Class 2
Regulation 21 CFR 882.4560
Establishment Manufacturer, Exporter
510(k) K160523
Record published 2016-11-11
Record revised 2025-08-06 (version 7)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Sterilisation Moist Heat or Steam Sterilization
Prescription Prescription only
Label carries manufacturing date, serial number

Catalogue Numbers

Catalogue numbers for BrightMatter Pointer
Catalogue number Size Status
SYN-0642 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Neurological Stereotaxic Instrument Medtronic Navigation, Inc. 844
PMT Corporation – Stereotactic PMT Corp. 255
Leksell Stereotactic System Elekta Instrument AB 199
Neurological Stereotaxic Instrument Inomed Medizintechnik Gmbh 146
Neurological Stereotaxic Instrument Stryker Leibinger Gmbh & Co. KG 125
Geniant Cranial KOH Young Technology Inc. 113
CRW® Integra Lifesciences Corporation 107
Leksell Stereotactic System Elekta Solutions AB 93
microTargeting™ Insertion Tube with Stylet FHC, Inc. 60
Leksell Stereotactic System Neurosurgical Instruments Elekta Instrument AB 58
Leksell Vantage Stereotactic System Elekta Instrument AB 53
Stealth Autoguide™ System Medtronic Navigation, Inc. 50

Showing 12 of 1,137. All products under Neurological Stereotaxic Instrument

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K183325 2019-07-14
K160523 2016-06-24
K153281 2016-03-30
K142024 2015-04-02

Recalls

1 of these is Class I. Class I is the FDA’s most serious grade: a reasonable probability of serious injury or death. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2018-10-09 Class I Software design This recall has been initiated due to a software defect found in the Guide System software when used with NICO BrainPath ports under certain circumstances. When one trajectory is set with a blue port and another trajectory is set with a gol 37 units 2021-08-12
2015-12-04 Class II Component design/selection Out of tolerance for radio frequency emissions. At the 150-1000MHz frequency, the testing indicated the BrightMatter Navigation system was up to 20dB uV/meter higher than the applicable IEC 60601-1-2:2007 (Ed3.0) standard specification. 8 2016-03-04

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer