Medtronic Navigation

SFW KIT 9735738 Stealth S8 CRN DBS EU-SE

Registry build 21.09.26
5manufacturers in China registered for this device type
43catalogue numbers in this listing
19510(k) clearances naming this product code
40recalls on this code

Who Else Makes It

Concentrated in Jiangsu (2), Shanghai (1), Shandong (1). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code HAW
Manufacturer City Province Registered as Device types
Paragon Medical Device (Changzhou) Co., Ltd. Changzhou Jiangsu Contract manufacturer 53
Shandong Weigao Orthopaedic Device Co., Ltd. Weihai Shandong Contract manufacturer 42
Zimmer (Shanghai) Medical International Trading Co., Ltd. Shanghai Shanghai Exporter 106
Medtronic (Changzhou) Medical Devices Technology Co., Ltd. Changzhou Jiangsu Manufacturer 53
Sinovation (Beijing) Medical Technology Co., Ltd. Beijing Beijing Manufacturer 1

Record

Regulatory record for Medtronic Navigation
Listed by Medtronic Navigation, Inc., United States
FDA product code HAW
Device type Neurological Stereotaxic Instrument
Device class Class 2
Regulation 21 CFR 882.4560
Establishment Specification developer, Repacker / relabeller, Manufacturer
510(k) K203639
Record published 2021-04-10
Record revised 2023-09-18 (version 2)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Prescription Prescription only
Label carries lot or batch number

Catalogue Numbers

Catalogue numbers for Medtronic Navigation
Catalogue number Size Status
9735737 In distribution
9735737 In distribution
9735738 In distribution
9735739 In distribution
9735917 In distribution
9735921 In distribution
9735738 In distribution
9735916 In distribution
9735739 In distribution
9735739 In distribution
9735916 In distribution
9735737 In distribution
9736025 In distribution
9735921 In distribution
9735916 In distribution
9735737 In distribution
9735739 In distribution
9735916 In distribution
9735737 In distribution
9735738 In distribution
9735739 In distribution
9735921 In distribution
9736025 In distribution
9735738 In distribution
9735738 In distribution
9735921 In distribution
9735739 In distribution
9735921 In distribution
9735918 In distribution
9735916 In distribution
9735737 In distribution
9736025 In distribution
9735917 In distribution
9736025 In distribution
9735918 In distribution
9735739 In distribution
9735738 In distribution
9735916 In distribution
9736025 In distribution
9735916 In distribution
9736025 In distribution
9736025 In distribution
9735737 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Neurological Stereotaxic Instrument Medtronic Navigation, Inc. 844
PMT Corporation – Stereotactic PMT Corp. 255
Leksell Stereotactic System Elekta Instrument AB 199
Neurological Stereotaxic Instrument Inomed Medizintechnik Gmbh 146
Neurological Stereotaxic Instrument Stryker Leibinger Gmbh & Co. KG 125
Geniant Cranial KOH Young Technology Inc. 113
CRW® Integra Lifesciences Corporation 107
Leksell Stereotactic System Elekta Solutions AB 93
microTargeting™ Insertion Tube with Stylet FHC, Inc. 60
Leksell Stereotactic System Neurosurgical Instruments Elekta Instrument AB 58
Leksell Vantage Stereotactic System Elekta Instrument AB 53
Stealth Autoguide™ System Medtronic Navigation, Inc. 50

Showing 12 of 1,137. All products under Neurological Stereotaxic Instrument

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K253379 2026-03-26
K231976 2023-10-19
K221087 2022-06-10
K212397 2021-12-22
K203639 2021-01-13
K201175 2020-06-03
K191597 2019-11-01
K190672 2019-07-31
K162655 2017-04-21
K162309 2017-03-31
K162604 2016-12-30
K153660 2016-09-14
K150216 2015-06-11
K141833 2015-03-25
K133444 2014-07-25
K130608 2013-08-07
K061248 2006-08-31
K052623 2006-03-02
K050651 2005-07-27

Recalls

7 of these are Class I. Class I is the FDA’s most serious grade: a reasonable probability of serious injury or death. Class II means a temporary or reversible health consequence. 1 is recorded with the root cause “No Marketing Application”: the device was distributed without the premarket submission its class requires, a compliance finding rather than a defect. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2024-03-26 Class I Software design Due to a software issue, there is the potential for a missing digit, letter, or decimal in either the “distance to target” or “tip stop point” display during navigation. 3286 applications.
2023-09-27 Class I Software design Due to a software anomaly which potentially could result in the surgical planning data shifting to an unintended location. 5,240 affected systems
2023-04-11 Class I Software design In nonaxial/some axial exams if surgical plan utilized, Target Guidance selected, tip projection utilized, Navigate Projection enabled, software anomaly may occur during tumor resection/shunt placement/deep brain stimulation, where distance 556
2023-04-11 Class I Software design During non-axial/some axial exams, software anomalies occur during procedures affecting depth gauge graphic displays for cranial biopsy; causing displays to no longer synchronize with other navigational information showing inaccurate values 746
2022-12-15 Class II Process control Due to increasing complaint trend for the Non-Invasive Patient Tracker system where complaints analysis indicates that users are unable to successfully verify their navigation instruments during image-guided surgery. 1,867 devies
2021-11-11 Class I Software design Cranial biopsy procedure software can enter a state where the biopsy depth gauge is no longer synchronized with the rest of the navigational information on the screen and may display an incorrect position of the biopsy needle, which may res 2587
2021-11-09 Class II Process control A tracker that holds and guides neurosurgical surgical instruments may be subject to separation/weld failure, where the tracker connects to the instrument tube. If a weld separation occurs and a navigation inaccuracy is experienced, it may 98
2020-06-05 Class II Nonconforming Material/Component There is a potential for specific camera units to be affected by a characterization issue during manufacturing that results in inaccurate navigation while utilizing both the active and passive trackers simultaneously. While no injuries or i 2 2024-05-28
2019-10-30 Class II Process control The firm has become aware that due to a manufacturing issue impacting the biopsy needle depth stop, there exist the potential that some biopsy needle depth stops, when tightened, may not securely tighten to the biopsy needle. This could r 10,448 disposable biopsy needles
2019-10-30 Class II Process control The firm has become aware that due to a manufacturing issue impacting the biopsy needle depth stop, there exist the potential that some biopsy needle depth stops, when tightened, may not securely tighten to the biopsy needle. This could r 12 disposable biopsy needles
2019-10-30 Class II Process control The firm has become aware that due to a manufacturing issue impacting the biopsy needle depth stop, there exist the potential that some biopsy needle depth stops, when tightened, may not securely tighten to the biopsy needle. This could r 1 disposable Biopsy Needle
2019-08-09 Class I Software design Entry point and lead placement inaccuracies during deep brain stimulation lead implantation procedures may occur when using a specific combination of the firm’s Steriotactic System and auto-registration feature with a specific imaging syste 61 customers purchased the specified combination of equipmen 2024-04-02
2018-09-26 Class I Device Design An incorrect display of the Biopsy Depth Gauge graphical representation in the Guidance View using Cranial software, which resulted in the biopsy of healthy tissue. 5487 impacted systems 2024-09-05
2017-05-10 Class II Software in the Use Environment Software issue related to the StealthStation S7 system and the Synergy Spine application Version 2.1 configured with Spine Tool Install CD version 25. Issue may result in user being unable to navigate the Navigated Elevate Inserter with th 108 2021-01-08
2016-12-12 Class II Process change control Medtronic Navigation, Inc. announces a voluntary field action for the AxIEM Touch N Go Pointer Probe because the patient registration accuracy may compromise navigation accuracy when using the StealthStation System with Touch N Go Pointer P 111 devices 2017-05-19
2016-07-18 Class II Software design Medtronic Navigation, Inc. announces a voluntary field action for the Medtronic Navigation StealthStation Software applications affected by Neurologica BodyTom/CereTom floor-based scanners. 27 in total 2016-12-01
2016-07-18 Class II Software design Medtronic Navigation, Inc. announces a voluntary field action for the Medtronic Navigation StealthStation Software applications affected by Neurologica BodyTom/CereTom floor-based scanners. 27 in total 2016-12-01
2016-07-18 Class II Software design Medtronic Navigation, Inc. announces a voluntary field action for the Medtronic Navigation StealthStation Software applications affected by Neurologica BodyTom/CereTom floor-based scanners. 27 in total 2016-12-01
2016-07-18 Class II Software design Medtronic Navigation, Inc. announces a voluntary field action for the Medtronic Navigation StealthStation Software applications affected by Neurologica BodyTom/CereTom floor-based scanners. 27 in total 2016-12-01
2016-07-18 Class II Software design Medtronic Navigation, Inc. announces a voluntary field action for the Medtronic Navigation StealthStation Software applications affected by Neurologica BodyTom/CereTom floor-based scanners. 27 in total 2016-12-01
2016-02-22 Class II No Marketing Application Medtronic Navigation is recalling the Biotex Adapter Kit because it was commercially distributed by BioTex without a cleared premarket [510(k)] from FDA. 4 2016-06-15
2015-09-14 Class II Labeling design Specific use conditions can increase the possibility of a screwdriver tip deforming or breaking during surgery. 2346 2015-12-03
2015-07-17 Class II Process change control The adhesive between the sphere assembly and the biopsy needle shaft may be compromised, causing the sphere assembly to move on the needle shaft. This may result in inaccurate navigation and improper placement of the needles biopsy window 1415 total 2016-04-07
2015-07-17 Class II Process change control The adhesive between the sphere assembly and the biopsy needle shaft may be compromised, causing the sphere assembly to move on the needle shaft. This may result in inaccurate navigation and improper placement of the needles biopsy window 1415 total 2016-04-07
2015-05-26 Class II Error in labeling Medtronic Navigation is initiating a field correction due to the potential for injury which could occur as a result of cleaning the Medtronic Navigated Cannulated Taps. 15,798 2015-10-23
2015-05-05 Class II Mixed-up of materials/components Passive Planar Blunt Probe (Lot# 150223) was manufactured with a sharp tip rather than a blunt tip. 18 2015-07-02
2014-04-24 Class II Nonconforming Material/Component Medtronic Navigation is recalling certain Medtronic single-use, disposable devices because there was not sufficient control to assure that returned, unused devices were appropriately examined for product and/or package damage to ensure ster 26,674 total 2014-12-29
2014-04-24 Class II Nonconforming Material/Component Medtronic Navigation is recalling certain Medtronic single-use, disposable devices because there was not sufficient control to assure that returned, unused devices were appropriately examined for product and/or package damage to ensure ster 26,674 total 2014-12-29
2014-04-24 Class II Nonconforming Material/Component Medtronic Navigation is recalling certain Medtronic single-use, disposable devices because there was not sufficient control to assure that returned, unused devices were appropriately examined for product and/or package damage to ensure ster 26,674 total 2014-12-29
2014-04-24 Class II Nonconforming Material/Component Medtronic Navigation is recalling certain Medtronic single-use, disposable devices because there was not sufficient control to assure that returned, unused devices were appropriately examined for product and/or package damage to ensure ster 26,674 total 2014-12-29
2014-04-24 Class II Nonconforming Material/Component Medtronic Navigation is recalling certain Medtronic single-use, disposable devices because there was not sufficient control to assure that returned, unused devices were appropriately examined for product and/or package damage to ensure ster 26,674 total 2014-12-29
2014-04-24 Class II Nonconforming Material/Component Medtronic Navigation is recalling certain Medtronic single-use, disposable devices because there was not sufficient control to assure that returned, unused devices were appropriately examined for product and/or package damage to ensure ster 26,674 total 2014-12-29
2014-04-24 Class II Nonconforming Material/Component Medtronic Navigation is recalling certain Medtronic single-use, disposable devices because there was not sufficient control to assure that returned, unused devices were appropriately examined for product and/or package damage to ensure ster 26,674 total 2014-12-29
2014-04-24 Class II Nonconforming Material/Component Medtronic Navigation is recalling certain Medtronic single-use, disposable devices because there was not sufficient control to assure that returned, unused devices were appropriately examined for product and/or package damage to ensure ster 26,674 total 2014-12-29
2014-04-24 Class II Nonconforming Material/Component Medtronic Navigation is recalling certain Medtronic single-use, disposable devices because there was not sufficient control to assure that returned, unused devices were appropriately examined for product and/or package damage to ensure ster 26,674 total 2014-12-29
2014-04-24 Class II Nonconforming Material/Component Medtronic Navigation is recalling certain Medtronic single-use, disposable devices because there was not sufficient control to assure that returned, unused devices were appropriately examined for product and/or package damage to ensure ster 26,674 total 2014-12-29
2014-04-24 Class II Nonconforming Material/Component Medtronic Navigation is recalling certain Medtronic single-use, disposable devices because there was not sufficient control to assure that returned, unused devices were appropriately examined for product and/or package damage to ensure ster 26,674 total 2014-12-29
2014-04-24 Class II Nonconforming Material/Component Medtronic Navigation is recalling certain Medtronic single-use, disposable devices because there was not sufficient control to assure that returned, unused devices were appropriately examined for product and/or package damage to ensure ster 26,674 total 2014-12-29
2014-04-24 Class II Nonconforming Material/Component Medtronic Navigation is recalling certain Medtronic single-use, disposable devices because there was not sufficient control to assure that returned, unused devices were appropriately examined for product and/or package damage to ensure ster 26,674 total 2014-12-29
2014-04-24 Class II Nonconforming Material/Component Medtronic Navigation is recalling certain Medtronic single-use, disposable devices because there was not sufficient control to assure that returned, unused devices were appropriately examined for product and/or package damage to ensure ster 26,674 total 2014-12-29

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer