Microtargeting™ Drive System
microTargeting(TM) Drive System compatible with mT Controller Contains: - Verification Probe - microTargeting(TM) Drive - Drive mount and Guide - microTargeting(TM) Sterilization Case - DBS…
microTargeting(TM) Drive System compatible with mT Controller Contains: – Verification Probe – microTargeting(TM) Drive – Drive mount and Guide – microTargeting(TM) Sterilization Case – DBS Measurment Fixture – DBS Adapter for microTargeting(TM) Drive – Matrix Guide Bushings – Lumen Cleaning Tool – Accessories kit
Who Else Makes It
Concentrated in Jiangsu (2), Shanghai (1), Shandong (1). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Paragon Medical Device (Changzhou) Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 53 |
| Shandong Weigao Orthopaedic Device Co., Ltd. | Weihai | Shandong | Contract manufacturer | 42 |
| Zimmer (Shanghai) Medical International Trading Co., Ltd. | Shanghai | Shanghai | Exporter | 106 |
| Medtronic (Changzhou) Medical Devices Technology Co., Ltd. | Changzhou | Jiangsu | Manufacturer | 53 |
| Sinovation (Beijing) Medical Technology Co., Ltd. | Beijing | Beijing | Manufacturer | 1 |
Record
| Listed by | FHC, Inc., United States |
|---|---|
| FDA product code | HAW |
| Device type | Neurological Stereotaxic Instrument |
| Device class | Class 2 |
| Regulation | 21 CFR 882.4560 |
| Establishment | Complaint-file establishment, Manufacturer |
| 510(k) | K011775 |
| Record published | 2016-09-17 |
| Record revised | 2018-07-06 (version 3) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Sterilisation | Hydrogen Peroxide, Moist Heat or Steam Sterilization, Ethylene Oxide |
| Prescription | Prescription only |
| Label carries | serial number |
| Storage | Storage environment temperature -34 to 57 °C |
| UDI direct marking | Exempt |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| MT-DS-01-00350 | In distribution | |
| MT-DS-00352 | In distribution | |
| FC1006-00147 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Neurological Stereotaxic Instrument | Medtronic Navigation, Inc. | 844 |
| PMT Corporation – Stereotactic | PMT Corp. | 255 |
| Leksell Stereotactic System | Elekta Instrument AB | 199 |
| Neurological Stereotaxic Instrument | Inomed Medizintechnik Gmbh | 146 |
| Neurological Stereotaxic Instrument | Stryker Leibinger Gmbh & Co. KG | 125 |
| Geniant Cranial | KOH Young Technology Inc. | 113 |
| CRW® | Integra Lifesciences Corporation | 107 |
| Leksell Stereotactic System | Elekta Solutions AB | 93 |
| microTargeting™ Insertion Tube with Stylet | FHC, Inc. | 60 |
| Leksell Stereotactic System Neurosurgical Instruments | Elekta Instrument AB | 58 |
| Leksell Vantage Stereotactic System | Elekta Instrument AB | 53 |
| Stealth Autoguide™ System | Medtronic Navigation, Inc. | 50 |
Showing 12 of 1,137. All products under Neurological Stereotaxic Instrument
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K121950 | 2012-07-26 |
| K092192 | 2010-02-12 |
| K092562 | 2009-09-18 |
| K011775 | 2001-08-30 |
| K011992 | 2001-08-14 |
| K003776 | 2001-02-23 |
Recalls Naming This Product
8 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| FHC, Inc. | 510(k) number | 2024-10-04 | Class I | Process change control | A complaint was received (MDR 3002250546-2024-00003) prompting an investigation. The investigation revealed a schematic for a spacer tube which is too long relative to the size of other components was included in the build order for Lot 244 | 8 packs of 5ea (40 total) | |
| FHC, Inc. | 510(k) number | 2018-05-10 | Class II | Device Design | The FHC Depth Stop Adapter may cause damage to the lead and stylet when the depth stop screw is over-tightened onto the lead. This damage can manifest as low impedances or a short circuit between one or multiple electrode pairs in the lead, | 2952 total | 2019-04-30 |
| FHC, Inc. | 510(k) number | 2018-05-10 | Class II | Device Design | The FHC Depth Stop Adapter may cause damage to the lead and stylet when the depth stop screw is over-tightened onto the lead. This damage can manifest as low impedances or a short circuit between one or multiple electrode pairs in the lead, | 2952 total | 2019-04-30 |
| FHC, Inc. | 510(k) number | 2018-05-10 | Class II | Device Design | The FHC Depth Stop Adapter may cause damage to the lead and stylet when the depth stop screw is over-tightened onto the lead. This damage can manifest as low impedances or a short circuit between one or multiple electrode pairs in the lead, | 2952 total | 2019-04-30 |
| FHC, Inc. | 510(k) number | 2018-05-10 | Class II | Device Design | The FHC Depth Stop Adapter may cause damage to the lead and stylet when the depth stop screw is over-tightened onto the lead. This damage can manifest as low impedances or a short circuit between one or multiple electrode pairs in the lead, | 2952 total | 2019-04-30 |
| FHC, Inc. | 510(k) number | 2018-05-10 | Class II | Device Design | The FHC Depth Stop Adapter may cause damage to the lead and stylet when the depth stop screw is over-tightened onto the lead. This damage can manifest as low impedances or a short circuit between one or multiple electrode pairs in the lead, | 2952 total | 2019-04-30 |
| FHC, Inc. | 510(k) number | 2018-05-10 | Class II | Device Design | The FHC Depth Stop Adapter may cause damage to the lead and stylet when the depth stop screw is over-tightened onto the lead. This damage can manifest as low impedances or a short circuit between one or multiple electrode pairs in the lead, | 2952 total | 2019-04-30 |
| FHC, Inc. | 510(k) number | 2005-03-14 | Not classified | Other | Potential for non-sterile pin to contaminate sterile field | 169 units | 2008-07-08 |
Recalls
9 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2018-05-10 | Class II | Device Design | The FHC Depth Stop Adapter may cause damage to the lead and stylet when the depth stop screw is over-tightened onto the lead. This damage can manifest as low impedances or a short circuit between one or multiple electrode pairs in the lead, | 2952 total | 2019-04-30 |
| 2018-05-10 | Class II | Device Design | The FHC Depth Stop Adapter may cause damage to the lead and stylet when the depth stop screw is over-tightened onto the lead. This damage can manifest as low impedances or a short circuit between one or multiple electrode pairs in the lead, | 2952 total | 2019-04-30 |
| 2018-05-10 | Class II | Device Design | The FHC Depth Stop Adapter may cause damage to the lead and stylet when the depth stop screw is over-tightened onto the lead. This damage can manifest as low impedances or a short circuit between one or multiple electrode pairs in the lead, | 2952 total | 2019-04-30 |
| 2018-05-10 | Class II | Device Design | The FHC Depth Stop Adapter may cause damage to the lead and stylet when the depth stop screw is over-tightened onto the lead. This damage can manifest as low impedances or a short circuit between one or multiple electrode pairs in the lead, | 2952 total | 2019-04-30 |
| 2018-05-10 | Class II | Device Design | The FHC Depth Stop Adapter may cause damage to the lead and stylet when the depth stop screw is over-tightened onto the lead. This damage can manifest as low impedances or a short circuit between one or multiple electrode pairs in the lead, | 2952 total | 2019-04-30 |
| 2018-05-10 | Class II | Device Design | The FHC Depth Stop Adapter may cause damage to the lead and stylet when the depth stop screw is over-tightened onto the lead. This damage can manifest as low impedances or a short circuit between one or multiple electrode pairs in the lead, | 2952 total | 2019-04-30 |
| 2018-05-10 | Class II | Device Design | The FHC Depth Stop Adapter may cause damage to the lead and stylet when the depth stop screw is over-tightened onto the lead. This damage can manifest as low impedances or a short circuit between one or multiple electrode pairs in the lead, | 2952 total | 2019-04-30 |
| 2018-05-10 | Class II | Device Design | The FHC Depth Stop Adapter may cause damage to the lead and stylet when the depth stop screw is over-tightened onto the lead. This damage can manifest as low impedances or a short circuit between one or multiple electrode pairs in the lead, | 2952 total | 2019-04-30 |
| 2018-05-10 | Class II | Device Design | The FHC Depth Stop Adapter may cause damage to the lead and stylet when the depth stop screw is over-tightened onto the lead. This damage can manifest as low impedances or a short circuit between one or multiple electrode pairs in the lead, | 2952 total | 2019-04-30 |
| 2010-03-30 | Not classified | Device Design | Fixation thumbscrew on the DBS depth stop adapter may be overtightened and damage the implantable lead. | 18 units | 2015-02-25 |
| 2010-03-30 | Not classified | Device Design | Fixation thumbscrew on the DBS depth stop adapter may be overtightened and damage the implantable lead. | 37 | 2015-02-25 |
| 2010-03-30 | Not classified | Device Design | Fixation thumbscrew on the DBS depth stop adapter may be overtightened and damage the implantable lead. | 7 | 2015-02-25 |
| 2010-03-30 | Not classified | Device Design | Fixation thumbscrew on the DBS depth stop adapter may be overtightened and damage the implantable lead. | 1 | 2015-02-25 |
| 2008-10-08 | Not classified | Process control | Measuring fixture is incorrectly graduated. | 5 units | 2012-05-02 |
| 2005-10-31 | Not classified | Other | Power Assist microTargeting System may advance beyond intended target | 70 units | 2006-06-07 |
| 2005-10-31 | Not classified | Other | Power Assist microTargeting System may advance beyond intended target | 230 units | 2006-06-07 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.