Neurological Stereotaxic Instrument

43 catalogue numbers from 20-8000-020-15, listed by Orthosoft, Inc., Canada, under Neurological Stereotaxic Instrument. 5 manufacturers in China are registered for this product code.

Registry build 21.09.26
5manufacturers in China registered for this device type
43catalogue numbers in this listing
12510(k) clearances naming this product code

Who Else Makes It

Concentrated in Jiangsu (2), Shanghai (1), Shandong (1). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code HAW
Manufacturer City Province Registered as Device types
Paragon Medical Device (Changzhou) Co., Ltd. Changzhou Jiangsu Contract manufacturer 53
Shandong Weigao Orthopaedic Device Co., Ltd. Weihai Shandong Contract manufacturer 42
Zimmer (Shanghai) Medical International Trading Co., Ltd. Shanghai Shanghai Exporter 106
Medtronic (Changzhou) Medical Devices Technology Co., Ltd. Changzhou Jiangsu Manufacturer 53
Sinovation (Beijing) Medical Technology Co., Ltd. Beijing Beijing Manufacturer 1

Record

Regulatory record for Neurological Stereotaxic Instrument
Listed by Orthosoft, Inc., Canada
FDA product code HAW
Device type Neurological Stereotaxic Instrument
Device class Class 2
Regulation 21 CFR 882.4560
510(k) K060336
Record published 2016-09-12
Record revised 2025-12-01 (version 7)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Sterilisation Moist Heat or Steam Sterilization
Single use Yes
Prescription Prescription only
Label carries lot or batch number
Sizes Outer diameter 3.2 to 6 mm; length 3.5 to 150 mm
Distribution end date 2020-09-30

Catalogue Numbers

Catalogue numbers for Neurological Stereotaxic Instrument
Catalogue number Size Per pack Status
20-8000-020-15 SZ6 Shape Configuration/Type In distribution
20-8000-020-26 In distribution
20-8000-020-27 In distribution
302.4002 In distribution
20-8000-000-02 Outer Diameter 3.2 mm In distribution
20-8000-070-21 In distribution
20-8011-070-02 In distribution
20-8000-070-65 In distribution
20-8011-070-03 In distribution
20-8000-000-01 Length 150 mm In distribution
20-8000-010-21 Withdrawn
20-8000-010-45 Outer Diameter 6 mm Withdrawn
20-8000-020-03 Withdrawn
20-8000-020-25 Withdrawn
20-8000-020-05 Withdrawn
20-8000-010-12 Withdrawn
20-8000-010-28 Withdrawn
20-8000-070-46 Withdrawn
20-8000-010-52 Withdrawn
20-8000-010-27 Withdrawn
20-8000-000-04 Outer Diameter 3.2 mm 12 Withdrawn
20-8000-010-30 Withdrawn
20-8000-010-11 Withdrawn
20-8000-000-03 Outer Diameter 3.2 mm 12 Withdrawn
20-8000-010-47 Withdrawn
20-8000-020-11 Withdrawn
20-8000-010-01 Withdrawn
20-8000-020-16 Withdrawn
20-8000-020-12 Withdrawn
20-8000-020-13 SZ3 Shape Configuration/Type Withdrawn
20-8000-020-04 Withdrawn
20-8000-010-49 Outer Diameter 6 mm Withdrawn
20-8000-010-23 Withdrawn
20-8000-020-20 Withdrawn
20-8000-020-21 8×1.25 pitch diameter Withdrawn
20-8000-070-11 Withdrawn
20-8000-020-24 Withdrawn
20-8000-010-54 Length 3.5 mm Withdrawn
20-8000-010-31 Withdrawn
20-8000-010-50 Withdrawn
20-8000-020-14 SZ3 Shape Configuration/Type Withdrawn
20-8000-010-48 Withdrawn
20-8000-020-10 Withdrawn

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Neurological Stereotaxic Instrument Medtronic Navigation, Inc. 844
PMT Corporation – Stereotactic PMT Corp. 255
Leksell Stereotactic System Elekta Instrument AB 199
Neurological Stereotaxic Instrument Inomed Medizintechnik Gmbh 146
Neurological Stereotaxic Instrument Stryker Leibinger Gmbh & Co. KG 125
Geniant Cranial KOH Young Technology Inc. 113
CRW® Integra Lifesciences Corporation 107
Leksell Stereotactic System Elekta Solutions AB 93
microTargeting™ Insertion Tube with Stylet FHC, Inc. 60
Leksell Stereotactic System Neurosurgical Instruments Elekta Instrument AB 58
Leksell Vantage Stereotactic System Elekta Instrument AB 53
Stealth Autoguide™ System Medtronic Navigation, Inc. 50

Showing 12 of 1,137. All products under Neurological Stereotaxic Instrument

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K071929 2007-09-19
K071714 2007-07-20
K060336 2006-04-28
K043536 2005-01-14
K041369 2004-06-22
K032917 2003-10-21
K030827 2003-05-23
K031156 2003-05-09
K022364 2003-02-04
K021760 2002-08-27
K002053 2000-08-03
K981315 1998-07-09

Recalls Naming This Product

10 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of Neurological Stereotaxic Instrument
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Zimmer CAS 510(k) number 2022-01-07 Class II Under Investigation by firm The product was released for distribution without passing sterilization results, which could potentially lead to insufficient sterility of the product. The highest severity risk is infection leading to surgical intervention. 14 units US; 132 units OUS
Zimmer CAS 510(k) number 2017-02-20 Class II Other There has been an increase in the number of complaints regarding bent or broken Drive Pins of the Validation Tool manufactured with drawing Revision M to P 84 2017-09-18
Zimmer CAS 510(k) number 2015-04-19 Class II Device Design Zimmer CAS has determined that the potential exists for the spikes on the iASSIST Tibial Alignment Guide to bend or break during insertion or extraction from the tibia during use. 78 devices 2016-05-13
Zimmer CAS 510(k) number 2011-10-06 Class II Software design Zimmer CAS voluntarily conducted a retrospective recall of the Navitrack System – OS Knee Universal software ORTHOsoft-UniTkr-2.3.2.6, due to a calibration sequence crash. 105 2017-05-08
Zimmer, Inc. 510(k) number 2009-11-02 Not classified Device Design The power cord female receptacle is not recessed sufficiently and may present a shock hazard. 71 2010-10-15
Zimmer CAS 510(k) number 2008-10-28 Class II Software design Zimmer CAS voluntarily conducted a retrospective recall of the Navitrack System OS Knee Universal software versions 2.2.0.82, 2.2.1.3, 2.1.6.0.2, D.54 and A.42 due to software issues resulting in erros and discrepancies. 153 2017-05-15
Zimmer, Inc. 510(k) number 2008-08-19 Not classified Software design Incorrect parameters: If the user switches from one surgeon profile to another surgeon profile after completing anatomical landmark acquisition tasks, the application will continue to use the initial surgeon profile parameter values in the 75 (34 U.S. and 41 international) 2010-04-28
Zimmer CAS 510(k) number 2008-06-20 Class III Software design ZIMMER CAS voluntarily conducted a retrospective recall of the Navitrack System – OS Knee Universal, due to software anomalies which were corrected with a new revision in version 2.2.1.3. 152 2017-05-15
Zimmer, Inc. 510(k) number 2007-08-06 Not classified Device Design Inadequate weld on tracker, knob oversized and poor thread design on attachment screw results in seizing.
The instrument may break during use, resulting in surgical delay and an increased risk of infection.
39 2009-03-11
Zimmer, Inc. 510(k) number 2006-04-27 Not classified Device Design The three-point array may break during use, resulting in surgical delay and an increased risk of infection. 239 2009-03-11

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer