OR-Side-Rail Adapter FOR Supporting ARM

Catalogue number 53089-01, listed by Brainlab SE, Germany, under Neurological Stereotaxic Instrument. 5 manufacturers in China are registered for this product code.

Registry build 21.09.26
5manufacturers in China registered for this device type
1catalogue number
9recalls on this code

Who Else Makes It

Concentrated in Jiangsu (2), Shanghai (1), Shandong (1). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code HAW
Manufacturer City Province Registered as Device types
Paragon Medical Device (Changzhou) Co., Ltd. Changzhou Jiangsu Contract manufacturer 53
Shandong Weigao Orthopaedic Device Co., Ltd. Weihai Shandong Contract manufacturer 42
Zimmer (Shanghai) Medical International Trading Co., Ltd. Shanghai Shanghai Exporter 106
Medtronic (Changzhou) Medical Devices Technology Co., Ltd. Changzhou Jiangsu Manufacturer 53
Sinovation (Beijing) Medical Technology Co., Ltd. Beijing Beijing Manufacturer 1

Record

Regulatory record for OR-Side-Rail Adapter FOR Supporting ARM
Listed by Brainlab SE, Germany
FDA product code HAW
Device type Neurological Stereotaxic Instrument
Device class Class 2
Regulation 21 CFR 882.4560
Establishment Manufacturer, Exporter
Record published 2019-05-22
Record revised 2026-03-19 (version 8)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Prescription Prescription only
Label carries serial number

Catalogue Numbers

Catalogue numbers for OR-Side-Rail Adapter FOR Supporting ARM
Catalogue number Size Status
53089-01 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Neurological Stereotaxic Instrument Medtronic Navigation, Inc. 844
PMT Corporation – Stereotactic PMT Corp. 255
Leksell Stereotactic System Elekta Instrument AB 199
Neurological Stereotaxic Instrument Inomed Medizintechnik Gmbh 146
Neurological Stereotaxic Instrument Stryker Leibinger Gmbh & Co. KG 125
Geniant Cranial KOH Young Technology Inc. 113
CRW® Integra Lifesciences Corporation 107
Leksell Stereotactic System Elekta Solutions AB 93
microTargeting™ Insertion Tube with Stylet FHC, Inc. 60
Leksell Stereotactic System Neurosurgical Instruments Elekta Instrument AB 58
Leksell Vantage Stereotactic System Elekta Instrument AB 53
Stealth Autoguide™ System Medtronic Navigation, Inc. 50

Showing 12 of 1,137. All products under Neurological Stereotaxic Instrument

Recalls

2 of these are Class I. Class I is the FDA’s most serious grade: a reasonable probability of serious injury or death. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2020-08-31 Class II Software design Brainlab Ultrasound Navigation Software does not support the modification of the probe’s image width. 271 units 2021-02-17
2019-02-27 Class I Software design In certain occurrences, the affected navigation software application might unexpectedly display a navigated instrument in an axial, coronal/sagittal (ACS) view representation with fixed planes in the image reconstruction (the not-updated A 148 units 2019-07-10
2017-11-16 Class II Nonconforming Material/Component Due to a human error at a supplier, an unknown number of devices within one specific production lot of Brainlab DrapeLink Adapters (Left/Right) were not
manufactured according to defined specifications.
80 devices total 2020-08-24
2015-08-18 Class II Process control Disposable Reflective Marker Spheres (DRMS) for Brainlab Image Guided Surgery (IGS) Systems: DRMS spheres may separate at the mid-point where the two halves of the sphere are sealed together. For 28 US consignees, 9,900 Disposable reflective marker sph 2017-01-05
2015-05-08 Class II Nonconforming Material/Component Instances of data sets not being accurately registered to the patient anatomy were observed. 12 systems total (10 in U.S., 2 in Australia) 2017-02-28
2014-05-21 Class II Software in the Use Environment Brainlab Navigation Software Spine & Trauma 3D 2.0/2.1 offers automatic registration of intraoperatively acquired CT image data sets. To enable automatic registration, the software requires the gantry position of the scanner.

The gantry p

17 systems 2017-03-13
2013-11-18 Class II Software design The “fluoro match registration” function of the Navigation Software Spine & Trauma 3D 2.0 allows the user to intraoperatively match e.g., CT data sets to the current patient anatomy visible on fluoroscopic images, used by the navigation sof 133 units 2017-07-17
2013-11-15 Class II Nonconforming Material/Component Brainlab has determined that pins of thee Instrument Star Unit ML (Calibration with ICM4) with specific serial numbers might have been made of an incorrect material that is not suitable for the necessary disinfection and sterilization of th 25 units 2017-03-13
2013-04-22 Class I Software in the Use Environment Software Error: The effect of setup on overall navigation accuracy could potentially intensify small inaccuracies arising from individual steps of a complex navigation procedure that may cause an inaccurate display of instruments by the nav 2528 units / 2119 consignees 2018-04-17

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA.

Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker