Planning Station Rosa One

planning station DELL 7520 Querty power plug B for Rosa One 3.1.4.0

Registry build 21.09.26
5manufacturers in China registered for this device type
1catalogue number
5recalls on this code

Who Else Makes It

Concentrated in Jiangsu (2), Shanghai (1), Shandong (1). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code HAW
Manufacturer City Province Registered as Device types
Paragon Medical Device (Changzhou) Co., Ltd. Changzhou Jiangsu Contract manufacturer 53
Shandong Weigao Orthopaedic Device Co., Ltd. Weihai Shandong Contract manufacturer 42
Zimmer (Shanghai) Medical International Trading Co., Ltd. Shanghai Shanghai Exporter 106
Medtronic (Changzhou) Medical Devices Technology Co., Ltd. Changzhou Jiangsu Manufacturer 53
Sinovation (Beijing) Medical Technology Co., Ltd. Beijing Beijing Manufacturer 1

Record

Regulatory record for Planning Station Rosa One
Listed by Medtech LLC, United States
FDA product code HAW
Device type Neurological Stereotaxic Instrument
Device class Class 2
Regulation 21 CFR 882.4560
Establishment Contract manufacturer, Manufacturer, Exporter
510(k) K200511
Record published 2020-07-17
Record revised 2025-05-30 (version 4)

Specifications

Specifications
MRI safety MR Unsafe
Prescription Prescription only
Label carries manufacturing date, serial number

Catalogue Numbers

Catalogue numbers for Planning Station Rosa One
Catalogue number Size Status
164017 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Neurological Stereotaxic Instrument Medtronic Navigation, Inc. 844
PMT Corporation – Stereotactic PMT Corp. 255
Leksell Stereotactic System Elekta Instrument AB 199
Neurological Stereotaxic Instrument Inomed Medizintechnik Gmbh 146
Neurological Stereotaxic Instrument Stryker Leibinger Gmbh & Co. KG 125
Geniant Cranial KOH Young Technology Inc. 113
CRW® Integra Lifesciences Corporation 107
Leksell Stereotactic System Elekta Solutions AB 93
microTargeting™ Insertion Tube with Stylet FHC, Inc. 60
Leksell Stereotactic System Neurosurgical Instruments Elekta Instrument AB 58
Leksell Vantage Stereotactic System Elekta Instrument AB 53
Stealth Autoguide™ System Medtronic Navigation, Inc. 50

Showing 12 of 1,137. All products under Neurological Stereotaxic Instrument

Recalls Naming This Product

1 recall names this product by its own identifier, the 510(k) it is cleared under.

Recalls naming the identifiers of Planning Station Rosa One
Recalled by Identified by Initiated FDA class Root cause Reason Quantity
Medtech LLC 510(k) number 2021-09-22 Class I Software design The firm has become aware of a software anomaly affecting ROSA One 3.1 Brain application which led to the inaccurate placement of an electrode during surgery. The firm has received 3 global complaints related to the issue. An incorrect traj 119 (US); 55 (OUS)

Recalls

1 of these is Class I. Class I is the FDA’s most serious grade: a reasonable probability of serious injury or death. Class II means a temporary or reversible health consequence. 1 is recorded with the root cause “No Marketing Application”: the device was distributed without the premarket submission its class requires, a compliance finding rather than a defect. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2020-01-06 Class II Software design Some cross-sectional images from the image acquisitions of the patients head may not be reconstructed/displayed properly in two and three dimension views when using ROSA Brain software, potentially compromising the surgery planning. 39 units 2020-11-05
2020-01-06 Class II Software design Some cross-sectional images from the image acquisitions of the patients head may not be reconstructed/displayed properly in two and three dimension views when using ROSA Brain software, potentially compromising the surgery planning. 47 units 2020-11-05
2019-09-10 Class I Software in the Use Environment The instrument holder may be sent on a trajectory that is not within the intended target. If it is not corrected, the associated device may be placed incorrectly. 93 2021-11-02
2018-05-08 Class II No Marketing Application Replacement of units lacking an updated device approval. 29 units 2020-08-19

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer