Registr. Matrix Imri Ge Headholder
4 catalogue numbers from 19202C, listed by Brainlab SE, Germany, under Neurological Stereotaxic Instrument. 5 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Jiangsu (2), Shanghai (1), Shandong (1). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Paragon Medical Device (Changzhou) Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 53 |
| Shandong Weigao Orthopaedic Device Co., Ltd. | Weihai | Shandong | Contract manufacturer | 42 |
| Zimmer (Shanghai) Medical International Trading Co., Ltd. | Shanghai | Shanghai | Exporter | 106 |
| Medtronic (Changzhou) Medical Devices Technology Co., Ltd. | Changzhou | Jiangsu | Manufacturer | 53 |
| Sinovation (Beijing) Medical Technology Co., Ltd. | Beijing | Beijing | Manufacturer | 1 |
Record
| Listed by | Brainlab SE, Germany |
|---|---|
| FDA product code | HAW |
| Device type | Neurological Stereotaxic Instrument |
| Device class | Class 2 |
| Regulation | 21 CFR 882.4560 |
| Establishment | Manufacturer, Exporter |
| 510(k) | K092467 |
| Record published | 2016-09-17 |
| Record revised | 2026-04-28 (version 8) |
Specifications
| MRI safety | MR Conditional |
|---|---|
| Prescription | Prescription only |
| Label carries | serial number |
| Distribution end date | 2024-10-21 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 19202C | Withdrawn | |
| 19202B | Withdrawn | |
| 19202-01C | Withdrawn | |
| 19202-20C | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Neurological Stereotaxic Instrument | Medtronic Navigation, Inc. | 844 |
| PMT Corporation – Stereotactic | PMT Corp. | 255 |
| Leksell Stereotactic System | Elekta Instrument AB | 199 |
| Neurological Stereotaxic Instrument | Inomed Medizintechnik Gmbh | 146 |
| Neurological Stereotaxic Instrument | Stryker Leibinger Gmbh & Co. KG | 125 |
| Geniant Cranial | KOH Young Technology Inc. | 113 |
| CRW® | Integra Lifesciences Corporation | 107 |
| Leksell Stereotactic System | Elekta Solutions AB | 93 |
| microTargeting™ Insertion Tube with Stylet | FHC, Inc. | 60 |
| Leksell Stereotactic System Neurosurgical Instruments | Elekta Instrument AB | 58 |
| Leksell Vantage Stereotactic System | Elekta Instrument AB | 53 |
| Stealth Autoguide™ System | Medtronic Navigation, Inc. | 50 |
Showing 12 of 1,137. All products under Neurological Stereotaxic Instrument
Recalls Naming This Product
2 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Brainlab SE | 510(k) number | 2020-08-31 | Class II | Software design | Brainlab Ultrasound Navigation Software does not support the modification of the probe’s image width. | 271 units | 2021-02-17 |
| Brainlab SE | 510(k) number | 2013-04-22 | Class I | Software in the Use Environment | Software Error: The effect of setup on overall navigation accuracy could potentially intensify small inaccuracies arising from individual steps of a complex navigation procedure that may cause an inaccurate display of instruments by the nav | 2528 units / 2119 consignees | 2018-04-17 |
Recalls
1 of these is Class I. Class I is the FDA’s most serious grade: a reasonable probability of serious injury or death. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2019-02-27 | Class I | Software design | In certain occurrences, the affected navigation software application might unexpectedly display a navigated instrument in an axial, coronal/sagittal (ACS) view representation with fixed planes in the image reconstruction (the not-updated A | 148 units | 2019-07-10 |
| 2017-11-16 | Class II | Nonconforming Material/Component | Due to a human error at a supplier, an unknown number of devices within one specific production lot of Brainlab DrapeLink Adapters (Left/Right) were not manufactured according to defined specifications. | 80 devices total | 2020-08-24 |
| 2015-08-18 | Class II | Process control | Disposable Reflective Marker Spheres (DRMS) for Brainlab Image Guided Surgery (IGS) Systems: DRMS spheres may separate at the mid-point where the two halves of the sphere are sealed together. | For 28 US consignees, 9,900 Disposable reflective marker sph | 2017-01-05 |
| 2015-05-08 | Class II | Nonconforming Material/Component | Instances of data sets not being accurately registered to the patient anatomy were observed. | 12 systems total (10 in U.S., 2 in Australia) | 2017-02-28 |
| 2014-05-21 | Class II | Software in the Use Environment | Brainlab Navigation Software Spine & Trauma 3D 2.0/2.1 offers automatic registration of intraoperatively acquired CT image data sets. To enable automatic registration, the software requires the gantry position of the scanner. The gantry p | 17 systems | 2017-03-13 |
| 2013-11-18 | Class II | Software design | The “fluoro match registration” function of the Navigation Software Spine & Trauma 3D 2.0 allows the user to intraoperatively match e.g., CT data sets to the current patient anatomy visible on fluoroscopic images, used by the navigation sof | 133 units | 2017-07-17 |
| 2013-11-15 | Class II | Nonconforming Material/Component | Brainlab has determined that pins of thee Instrument Star Unit ML (Calibration with ICM4) with specific serial numbers might have been made of an incorrect material that is not suitable for the necessary disinfection and sterilization of th | 25 units | 2017-03-13 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA.
Records are records: nothing here is an offer of sale.