Atec Posterior Navigation Disc Prep Instruments

ATEC Posterior Navigation Disc Prep Instruments are reusable surgical tools for discectomy, bony resection and implant-size selection during spinal surgery. They are designed for use with…

Registry build 21.09.26

ATEC Posterior Navigation Disc Prep Instruments are reusable surgical tools for discectomy, bony resection and implant-size selection during spinal surgery. They are designed for use with the Medtronic StealthStation navigation system.

Disc-preparation instruments act on disc or bone, while navigated trials help select the size of Alphatec interbody fusion implants. The trials are procedural tools rather than permanently implanted spacers.

Listed Item

Post NAV Right-Bend CUP Curette, Size 2

Navigation and Preparation

The navigation workflow references rigid anatomy to CT, MR, fluoroscopic or digitized anatomical data. The instruments are supplied nonsterile and require cleaning and steam sterilization by the user before reuse.

5manufacturers in China registered for this device type
50catalogue numbers in this listing
7510(k) clearances naming this product code
3recalls on this code

Who Else Makes It

Concentrated in Jiangsu (2), Shanghai (1), Guangdong (1). 3 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code OLO
Manufacturer City Province Registered as Device types
Apex (Guangzhou) Tools & Orthopedics Company Guangzhou Guangdong Contract manufacturer 62
Paragon Medical Device (Changzhou) Co., Ltd. Changzhou Jiangsu Contract manufacturer 53
Shandong Weigao Orthopaedic Device Co., Ltd. Weihai Shandong Contract manufacturer 42
Zimmer (Shanghai) Medical International Trading Co., Ltd. Shanghai Shanghai Exporter 106
Medtronic (Changzhou) Medical Devices Technology Co., Ltd. Changzhou Jiangsu Manufacturer 53

Record

Regulatory record for Atec Posterior Navigation Disc Prep Instruments
Listed by Alphatec Spine, Inc., United States
FDA product code OLO
Device type Orthopedic Stereotaxic Instrument
Device class Class 2
Regulation 21 CFR 882.4560
Establishment Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter
510(k) K232345
Record published 2024-04-20
Record revised 2026-05-29 (version 2)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Sterilisation Moist Heat or Steam Sterilization
Prescription Prescription only
Label carries lot or batch number
Sizes Width 6 to 14 mm; height 7 to 11 mm; length 22 mm; angle 5 to 15 °; outer diameter 6 to 10 mm
Distribution end date 2026-01-02

Catalogue Numbers

Catalogue numbers for Atec Posterior Navigation Disc Prep Instruments
Catalogue number Size Status
244-17-000-10-N Width 10 mm In distribution
244-05-07092205-N Width 9 mm In distribution
244-14-400-02-N In distribution
244-05-08092210-N Length 22 mm In distribution
244-03-000-06-N Width 6 mm In distribution
244-05-08092205-N Height 8 mm In distribution
244-03-000-10-N Width 10 mm In distribution
244-03-000-09-N Width 9 mm In distribution
244-17-000-09-N Width 9 mm In distribution
244-05-07092210-N Height 7 mm In distribution
244-05-10092200-N Height 10 mm In distribution
244-05-11092200-N Width 9 mm In distribution
244-05-09092215-N Height 9 mm In distribution
244-03-000-13-N Width 13 mm In distribution
244-05-11092215-N Height 11 mm In distribution
244-05-09092200-N Width 9 mm In distribution
244-03-000-07-N Width 7 mm In distribution
244-05-11092205-N Angle 5 ° In distribution
244-11-000-10-N Outer Diameter 10 mm In distribution
244-13-000-08-N Width 8 mm In distribution
244-17-000-07-N Width 7 mm In distribution
244-05-10092205-N Length 22 mm In distribution
244-17-000-11-N Width 11 mm In distribution
244-11-000-08-N Outer Diameter 8 mm In distribution
244-03-000-12-N Width 12 mm In distribution
244-11-000-06-N Outer Diameter 6 mm In distribution
244-05-09092205-N Height 9 mm In distribution
244-05-08092200-N Height 8 mm In distribution
244-03-000-14-N Width 14 mm In distribution
244-14-000-02-N In distribution
244-05-09092210-N Width 9 mm In distribution
244-17-000-13-N Width 13 mm In distribution
244-05-08092215-N Angle 15 ° In distribution
244-17-000-06-N Width 6 mm In distribution
244-17-000-12-N Width 12 mm In distribution
244-17-000-14-N Width 14 mm In distribution
244-05-11092210-N Length 22 mm In distribution
244-05-10092215-N Width 9 mm In distribution
244-14-300-02-N In distribution
244-14-020-02-N In distribution
244-05-10092210-N Angle 10 ° In distribution
244-03-000-08-N Width 8 mm In distribution
244-05-07092200-N Length 22 mm In distribution
244-17-000-08-N Width 8 mm In distribution
244-03-000-11-N Width 11 mm In distribution
244-13-000-06-N Width 6 mm In distribution
244-05-07092215-N Angle 15 ° In distribution
244-13-000-10-N Width 10 mm In distribution
244-01-000-06-N Width 6 mm Withdrawn
244-01-000-12-N Width 12 mm Withdrawn

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Valence Robotic Navigation System Alphatec Spine, Inc. 813
Olympic Astura Medical 684
Excelsius GPS Globus Medical, Inc. 383
Orthopedic Stereotaxic Instrument Medtronic Navigation, Inc. 356
Masada Astura Medical 335
Excelsiusgps Globus Medical, Inc. 297
Invictus Alphatec Spine, Inc. 235
OrthAlign Plus OrthAlign, Inc. 210
Arvis ® Kico Knee Innovation Company 174
OMNIBotics Omni Life Science, Inc. 150
CD Horizon® Spinal System Medtronic Sofamor Danek, Inc. 137
Navigation Instruments VB Spine LLC 135

Showing 12 of 1,127. All products under Orthopedic Stereotaxic Instrument

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K252597 2026-02-19
K240951 2024-06-06
K232345 2023-11-02
K232044 2023-10-06
K232413 2023-09-08
K223765 2023-03-23
K153603 2016-04-29

Recalls

3 of these are Class II. Class II means a temporary or reversible health consequence. 1 is recorded with the root cause “No Marketing Application”: the device was distributed without the premarket submission its class requires, a compliance finding rather than a defect. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity
2026-01-02 Class II Device Design Due a design issue where the navigated array connection geometry is incorrect. 7 units
2026-01-02 Class II Device Design Due a design issue where the navigated array connection geometry is incorrect. 15 units
2022-09-14 Class II No Marketing Application Due to manufacturing instruments which included additional features and adequate consideration was not given to the need for a new Regulatory filing. 42 devices

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer