Bendini
Bendini IR Probe Passive Sphere, 5 Pack
Who Else Makes It
Concentrated in Jiangsu (2), Shanghai (1), Guangdong (1). 3 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Apex (Guangzhou) Tools & Orthopedics Company | Guangzhou | Guangdong | Contract manufacturer | 62 |
| Paragon Medical Device (Changzhou) Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 53 |
| Shandong Weigao Orthopaedic Device Co., Ltd. | Weihai | Shandong | Contract manufacturer | 42 |
| Zimmer (Shanghai) Medical International Trading Co., Ltd. | Shanghai | Shanghai | Exporter | 106 |
| Medtronic (Changzhou) Medical Devices Technology Co., Ltd. | Changzhou | Jiangsu | Manufacturer | 53 |
Record
| Listed by | Nuvasive, Inc., United States |
|---|---|
| FDA product code | OLO |
| Device type | Orthopedic Stereotaxic Instrument |
| Device class | Class 2 |
| Regulation | 21 CFR 882.4560 |
| Establishment | Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter |
| 510(k) | K111811 |
| Record published | 2019-07-15 |
| Record revised | 2025-06-11 (version 6) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Sterilisation | Moist Heat or Steam Sterilization |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date, manufacturing date, serial number |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 1570780 | In distribution | |
| 1592700 | In distribution | |
| 2040001 | In distribution | |
| 8210010 | In distribution | |
| 1578787 | In distribution | |
| 8210006 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Valence Robotic Navigation System | Alphatec Spine, Inc. | 813 |
| Olympic | Astura Medical | 684 |
| Excelsius GPS | Globus Medical, Inc. | 383 |
| Orthopedic Stereotaxic Instrument | Medtronic Navigation, Inc. | 356 |
| Masada | Astura Medical | 335 |
| Excelsiusgps | Globus Medical, Inc. | 297 |
| Invictus | Alphatec Spine, Inc. | 235 |
| OrthAlign Plus | OrthAlign, Inc. | 210 |
| Arvis ® | Kico Knee Innovation Company | 174 |
| OMNIBotics | Omni Life Science, Inc. | 150 |
| CD Horizon® Spinal System | Medtronic Sofamor Danek, Inc. | 137 |
| Navigation Instruments | VB Spine LLC | 135 |
Showing 12 of 1,127. All products under Orthopedic Stereotaxic Instrument
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K233706 | 2024-08-02 |
| K122742 | 2012-12-07 |
| K111811 | 2011-12-05 |
Recalls Naming This Product
1 recall names this product by its own identifier, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Nuvasive, Inc. | 510(k) number | 2020-06-10 | Class II | Under Investigation by firm | The NVM5 EMG Module kit intended for intraoperative neurophysiologic monitoring during spinal surgery contains incorrect component, part number 1715945, SSEP harness instead of the the correct part number 1747065, NVM5 Harness, Gen 3.5 EM. | 23 | 2021-03-22 |
Recalls
1 of these is Class III. Class III is unlikely to cause harm at all → typically a labelling or documentation fault. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|
| 2022-07-19 | Class III | Software design | Due to an incorrect security key, customers were unable to connect to remote monitoring during spinal surgery, neck dissections, thoracic surgeries, and upper and lower extremity procedures. | 7 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.