| 2022-08-08 | Class II | Under Investigation by firm | Certain units have the potential to exhibit infant failures whereby units either arrive non-functional, have the potential to become non-functional, or flash an error light while in use. | 2 | 2026-05-22 |
| 2020-10-23 | Class II | Under Investigation by firm | Stryker has discovered a characterization issue associated with the Mako Integrated Cutting System (MICS) Handpiece. The MICS Handpiece is attached to the distal end of the robotic arm and is used to register the RIO and to execute bone pr | 367 units | |
| 2020-07-09 | Class II | Under Investigation by firm | Characterization issue associated with the product. This issue may cause a discrepancy during bone preparation in certain Mako Total Hip procedures. | 12 units | 2023-06-16 |
| 2019-04-25 | Class II | Under Investigation by firm | The bearings of the saw attachments were ungreased. | 7 | 2021-04-22 |
| 2019-04-25 | Class II | Under Investigation by firm | The bearings of the saw attachments were ungreased. | 39 | 2021-04-22 |
| 2018-07-24 | Class II | Under Investigation by firm | Specific lots of the Vizadisc Knee Procedure Tracking Kit and Vizadisc Hip Procedure Tracking Kit have the potential to be damaged on the Vizadisc reflective material causing an inability to be detected by the camera. | 19,906 total devices | 2022-10-11 |
| 2018-07-24 | Class II | Under Investigation by firm | Specific lots of the Vizadisc Knee Procedure Tracking Kit and Vizadisc Hip Procedure Tracking Kit have the potential to be damaged on the Vizadisc reflective material causing an inability to be detected by the camera. | 19,906 total devices | 2022-10-11 |
| 2017-08-07 | Class II | Software design | Software discrepancy of not showing all the EE constants, when the screen is filled. | 349 (US) and 78 (OUS) | 2019-08-06 |
| 2017-08-07 | Class II | Software design | Software discrepancy of not showing all the EE constants, when the screen is filled. | 291 (US) and 66 (OUS) | 2019-08-06 |
| 2017-06-07 | Class II | Employee error | An intermittent electrical problem that could lead to a loss of system power due to a loose screw connection. | 20 | 2020-06-16 |
| 2016-12-22 | Class II | Labeling design | Five (5) AFMEA Risk Control Measures are missing from the MAKO RIO THA Application User Guides | 777 | 2019-08-06 |
| 2016-09-29 | Class II | Component change control | Failure of the Offset Cup Reamer Handle not engaging its mating components. | 595 units | 2019-08-06 |
| 2016-02-23 | Class II | Nonconforming Material/Component | Potential disassociation of the orientation pin. | 96 | 2016-12-14 |
| 2015-11-25 | Class II | Component change control | Stryker Orthpaedics became aware that there is the potential for the 210540 MAKOplasty Hip Array Kit Laminate 150230 to list two part numbers for the RIO Base Array, which is item #5 on the product table. | 10 units. | 2016-08-25 |
| 2015-07-16 | Class II | Device Design | The locking pin on the RIO Base Array is damaged during assembly onto the RIO Base Array Connector. | 1,322 units | 2016-12-14 |
| 2015-01-22 | Class II | Device Design | When using the MAKOplasty partial knee Arthroplasty application, the burr continues spinning outside of the stereotactic boundary and after the control switches (foot pedal and trigger) cease to be activated | 228 units | 2016-12-14 |
| 2014-10-07 | Class II | Device Design | MAKO has identified the potential that the shell impactors may be damaged intraoperatively. | Total 404 | 2016-10-03 |
| 2014-10-07 | Class II | Device Design | MAKO has identified the potential that the shell impactors may be damaged intraoperatively. | Total 404 | 2016-10-03 |
| 2014-10-07 | Class II | Device Design | MAKO has identified the potential that the shell impactors may be damaged intraoperatively. | Total 404 | 2016-10-03 |
| 2014-04-30 | Class II | Process control | Revision of the field manual | 249 | 2019-07-24 |
| 2012-09-12 | Class II | Software design | MAKO Surgical Group recalled their RIO System software, version 2.4 and is implementing software version 2.5 to address a software functional issue with the existing version of the system’s software. Loss of tactile feedback constraining th | 137 devices | 2013-05-22 |
| 2011-01-20 | Not classified | Software change control | MAKO Surgical Corp. is recalling their RIO Robotic Arm Interactive Orthopedic System (RIO) due to software issue that exist that could potentially result in a bone resection. No adverse events reported. | 70 | 2011-12-13 |