Scapular Clamp

Catalogue number 190661, listed by Mako Surgical Corp., United States, under Orthopedic Stereotaxic Instrument. 5 manufacturers in China are registered for this product code.

Registry build 21.09.26
5manufacturers in China registered for this device type
1catalogue number
23510(k) clearances naming this product code
25recalls on this code

Who Else Makes It

Concentrated in Jiangsu (2), Shanghai (1), Guangdong (1). 3 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code OLO
Manufacturer City Province Registered as Device types
Apex (Guangzhou) Tools & Orthopedics Company Guangzhou Guangdong Contract manufacturer 62
Paragon Medical Device (Changzhou) Co., Ltd. Changzhou Jiangsu Contract manufacturer 53
Shandong Weigao Orthopaedic Device Co., Ltd. Weihai Shandong Contract manufacturer 42
Zimmer (Shanghai) Medical International Trading Co., Ltd. Shanghai Shanghai Exporter 106
Medtronic (Changzhou) Medical Devices Technology Co., Ltd. Changzhou Jiangsu Manufacturer 53

Record

Regulatory record for Scapular Clamp
Listed by Mako Surgical Corp., United States
FDA product code OLO
Device type Orthopedic Stereotaxic Instrument
Device class Class 2
Regulation 21 CFR 882.4560
Establishment Specification developer, Complaint-file establishment, Manufacturer
Record published 2026-01-30

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Sterilisation Moist Heat or Steam Sterilization
Prescription Prescription only
Latex Labelled latex-free
Label carries lot or batch number

Catalogue Numbers

Catalogue numbers for Scapular Clamp
Catalogue number Size Status
190661 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Valence Robotic Navigation System Alphatec Spine, Inc. 813
Olympic Astura Medical 684
Excelsius GPS Globus Medical, Inc. 383
Orthopedic Stereotaxic Instrument Medtronic Navigation, Inc. 356
Masada Astura Medical 335
Excelsiusgps Globus Medical, Inc. 297
Invictus Alphatec Spine, Inc. 235
OrthAlign Plus OrthAlign, Inc. 210
Arvis ® Kico Knee Innovation Company 174
OMNIBotics Omni Life Science, Inc. 150
CD Horizon® Spinal System Medtronic Sofamor Danek, Inc. 137
Navigation Instruments VB Spine LLC 135

Showing 12 of 1,127. All products under Orthopedic Stereotaxic Instrument

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K260222 2026-02-25
K250608 2025-04-25
K243751 2025-03-05
K242373 2024-11-07
K241011 2024-06-11
K220459 2022-04-15
K193515 2020-07-14
K193128 2020-02-02
K191998 2019-09-24
K172301 2017-11-02
K172219 2017-09-21
K170891 2017-05-24
K170581 2017-05-11
K170584 2017-05-11
K170593 2017-04-18
K142530 2015-09-16
K143752 2015-08-06
K141989 2014-11-13
K121064 2012-06-06
K112507 2012-03-01
K093425 2010-02-24
K091998 2009-09-28
K083644 2009-06-19

Recalls

24 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2022-08-08 Class II Under Investigation by firm Certain units have the potential to exhibit infant failures whereby units either arrive non-functional, have the potential to become non-functional, or flash an error light while in use. 2 2026-05-22
2020-10-23 Class II Under Investigation by firm Stryker has discovered a characterization issue associated with the Mako Integrated Cutting System (MICS) Handpiece. The MICS Handpiece is attached to the distal end of the robotic arm and is used to register the RIO and to execute bone pr 367 units
2020-07-09 Class II Under Investigation by firm Characterization issue associated with the product. This issue may cause a discrepancy during bone preparation in certain Mako Total Hip procedures. 12 units 2023-06-16
2019-04-25 Class II Under Investigation by firm The bearings of the saw attachments were ungreased. 7 2021-04-22
2019-04-25 Class II Under Investigation by firm The bearings of the saw attachments were ungreased. 39 2021-04-22
2018-07-24 Class II Under Investigation by firm Specific lots of the Vizadisc Knee Procedure Tracking Kit and Vizadisc Hip Procedure Tracking Kit have the potential to be damaged on the Vizadisc reflective material causing an inability to be detected by the camera. 19,906 total devices 2022-10-11
2018-07-24 Class II Under Investigation by firm Specific lots of the Vizadisc Knee Procedure Tracking Kit and Vizadisc Hip Procedure Tracking Kit have the potential to be damaged on the Vizadisc reflective material causing an inability to be detected by the camera. 19,906 total devices 2022-10-11
2018-05-10 Class II Nonconforming Material/Component Out of tolerance. 10,606 2021-01-17
2017-12-27 Class II Nonconforming Material/Component Communication-connection error. 736 (US) and 174 (OUS) 2020-12-14
2017-12-01 Class II Error in labeling Incorrect product and/or label. Sizing is labeled incorrectly. 126 2020-12-14
2017-08-07 Class II Software design Software discrepancy of not showing all the EE constants, when the screen is filled. 349 (US) and 78 (OUS) 2019-08-06
2017-08-07 Class II Software design Software discrepancy of not showing all the EE constants, when the screen is filled. 291 (US) and 66 (OUS) 2019-08-06
2017-06-07 Class II Employee error An intermittent electrical problem that could lead to a loss of system power due to a loose screw connection. 20 2020-06-16
2016-12-22 Class II Labeling design Five (5) AFMEA Risk Control Measures are missing from the MAKO RIO THA Application User Guides 777 2019-08-06
2016-09-29 Class II Component change control Failure of the Offset Cup Reamer Handle not engaging its mating components. 595 units 2019-08-06
2016-02-23 Class II Nonconforming Material/Component Potential disassociation of the orientation pin. 96 2016-12-14
2015-11-25 Class II Component change control Stryker Orthpaedics became aware that there is the potential for the 210540 MAKOplasty Hip Array Kit Laminate 150230 to list two part numbers for the RIO Base Array, which is item #5 on the product table. 10 units. 2016-08-25
2015-07-16 Class II Device Design The locking pin on the RIO Base Array is damaged during assembly onto the RIO Base Array Connector. 1,322 units 2016-12-14
2015-01-22 Class II Device Design When using the MAKOplasty partial knee Arthroplasty application, the burr continues spinning outside of the stereotactic boundary and after the control switches (foot pedal and trigger) cease to be activated 228 units 2016-12-14
2014-10-07 Class II Device Design MAKO has identified the potential that the shell impactors may be damaged intraoperatively. Total 404 2016-10-03
2014-10-07 Class II Device Design MAKO has identified the potential that the shell impactors may be damaged intraoperatively. Total 404 2016-10-03
2014-10-07 Class II Device Design MAKO has identified the potential that the shell impactors may be damaged intraoperatively. Total 404 2016-10-03
2014-04-30 Class II Process control Revision of the field manual 249 2019-07-24
2012-09-12 Class II Software design MAKO Surgical Group recalled their RIO System software, version 2.4 and is implementing software version 2.5 to address a software functional issue with the existing version of the system’s software. Loss of tactile feedback constraining th 137 devices 2013-05-22
2011-01-20 Not classified Software change control MAKO Surgical Corp. is recalling their RIO Robotic Arm Interactive Orthopedic System (RIO) due to software issue that exist that could potentially result in a bone resection. No adverse events reported. 70 2011-12-13

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer