1.5MM System
87 catalogue numbers from SP-3336, listed by Biomet Microfixation, United States, under Fastener, Plate, Cranioplasty. 3 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Jiangsu (1), Shanghai (1), Fujian (1). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Changzhou Biomet Medical Devices Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 54 |
| LX Precision Shanghai Co Ltd | Shanghai | Shanghai | Contract manufacturer | 19 |
| Quanzhou Apex Hygiene Products Co., Ltd. | Jinjiang | Fujian | Manufacturer | 8 |
Record
| Listed by | Biomet Microfixation, United States |
|---|---|
| FDA product code | HBW |
| Device type | Fastener, Plate, Cranioplasty |
| Device class | Class 2 |
| Regulation | 21 CFR 882.5360 |
| Establishment | Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer |
| 510(k) | K121624 |
| Record published | 2017-06-02 |
| Record revised | 2025-06-09 (version 8) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Sterilisation | Moist Heat or Steam Sterilization |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date |
| Distribution end date | 2020-07-27 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| SP-3336 | In distribution | |
| 01-7136 | In distribution | |
| SP-1266 | In distribution | |
| 95-6104 | In distribution | |
| SP-3002 | In distribution | |
| SP-3326 | In distribution | |
| 01-7308 | In distribution | |
| SP-2644 | In distribution | |
| SP-2905 | In distribution | |
| 01-7112 | In distribution | |
| SP-3325 | In distribution | |
| 99-7202 | In distribution | |
| 91-6103-50 | In distribution | |
| SP-2451 | In distribution | |
| 01-7104 | In distribution | |
| SP-2680 | In distribution | |
| SP-3329 | In distribution | |
| SP-3333 | In distribution | |
| SP-2082 | In distribution | |
| SP-2923 | In distribution | |
| SP-2883 | In distribution | |
| 91-1803 | In distribution | |
| SP-2062 | In distribution | |
| 01-7355 | In distribution | |
| 01-7055 | In distribution | |
| 01-7204 | In distribution | |
| SP-3445 | In distribution | |
| SP-2345 | In distribution | |
| SP-3444 | In distribution | |
| SP-3330 | In distribution | |
| 01-7040 | In distribution | |
| SP-2472 | In distribution | |
| 91-1507 | In distribution | |
| 95-6105 | In distribution | |
| SP-3223 | In distribution | |
| 91-6104-50 | In distribution | |
| SP-2455 | In distribution | |
| 01-7359 | In distribution | |
| 99-7225 | In distribution | |
| SP-2476 | In distribution | |
| 01-8678 | In distribution | |
| SP-2881 | In distribution | |
| 01-7137 | In distribution | |
| 01-7361 | In distribution | |
| 01-7131 | In distribution | |
| SP-2880 | In distribution | |
| 01-7062 | In distribution | |
| SP-3328 | In distribution | |
| 01-8679 | In distribution | |
| SP-3313 | In distribution | |
| SP-2683 | In distribution | |
| SP-3324 | In distribution | |
| 01-7132 | In distribution | |
| SP-3327 | In distribution | |
| 01-7045 | In distribution | |
| SP-2929 | In distribution | |
| 99-7207 | In distribution | |
| SP-2922 | In distribution | |
| SP-2882 | In distribution | |
| SP-3300 | In distribution | |
| 91-1805 | In distribution | |
| 99-7203 | In distribution | |
| 91-1506 | In distribution | |
| SP-3331 | In distribution | |
| 01-7345-5PK | Withdrawn | |
| SP-2450 | Withdrawn | |
| SP-2644 | Withdrawn | |
| SP-2929 | Withdrawn | |
| 91-6105X | Withdrawn | |
| SP-3033 | Withdrawn | |
| SP-3023 | Withdrawn | |
| SP-2524 | Withdrawn | |
| SP-2928 | Withdrawn | |
| 01-7112-5PK | Withdrawn | |
| SP-2138 | Withdrawn | |
| SP-2882 | Withdrawn | |
| 01-8689 | Withdrawn | |
| 01-8679 | Withdrawn | |
| SP-2888 | Withdrawn | |
| 01-7048-5PK | Withdrawn | |
| SP-2250 | Withdrawn | |
| SP-2451 | Withdrawn | |
| 01-8604 | Withdrawn | |
| SP-2336 | Withdrawn | |
| SP-2923 | Withdrawn | |
| SP-3002 | Withdrawn | |
| 01-8662 | Withdrawn |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Neuro Plating System | Osteonic Co., Ltd. | 55 |
| Universal Neuro 3 | Stryker Leibinger Gmbh & Co. KG | 40 |
| “2.0MM” System | Biomet Microfixation | 26 |
| Resorb XG, Sterile | KLS-Martin L.P. | 18 |
| Leforte Neuro System Bone Plate | Jeil Medical Corporation | 15 |
| CMF System | Biomet Microfixation | 14 |
| Fastener, Plate, Cranioplasty | Biomet Microfixation | 14 |
| AXS | Stryker Leibinger Gmbh & Co. KG | 14 |
| Raas Cranial Plating System | Alliance Partners, LLC | 12 |
| Thinflap System | Biomet Microfixation | 12 |
| Delta | Stryker Leibinger Gmbh & Co. KG | 11 |
| NeuroPro® Low Profile | Kinamed, Inc. | 10 |
Showing 12 of 45. All products under Fastener, Plate, Cranioplasty
Recalls Naming This Product
6 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Biomet Microfixation | 510(k) number | 2015-08-06 | Class II | Component change control | The lids on implant caddies within P/N 17-5000 and 19-5000 could not be opened by the user without application of undesirable/unexpected excessive force. | 37 cases | 2017-10-13 |
| Biomet Microfixation | 510(k) number | 2015-08-06 | Class II | Component change control | The lids on implant caddies within P/N 17-5000 and 19-5000 could not be opened by the user without application of undesirable/unexpected excessive force. | 5 units | 2017-10-13 |
| Biomet Microfixation | 510(k) number | 2010-07-28 | Not classified | Labeling mix-ups | Biomet Microfixation, Jacksonville, FL is recalling their 1.5 6 Hole Reg Double Y, Lots 785710, 753120, 693500 and 733600. This product is labeled as 01-7110-K (1.5 6 Hole Reg Double Y), however the package contains a 01-7112-K (1.5.6 Hold | 180 | 2011-06-24 |
| Biomet Microfixation | 510(k) number | 2010-04-26 | Not classified | Error in labeling | On 4/26/10 Biomet Microfixation, Jacksonville, FL initiated a recall of their 1.5 3/3 hole 100 degree left X-long L plate, Model #01-7036, Lot #193690. Product is labeled incorrectly. | 23 | 2012-04-18 |
| Biomet Microfixation | 510(k) number | 2009-10-06 | Not classified | Process control | Biomet Microfixation is recalling Model 01-7293 an Model 99-7293-01, 1.5X3.5mm Self Drilling, Low Profile, Cross Drive screw, 5/PK was found to contain a 91-6104 (1.5X4mm High Torque, Self Drilling, Cross Drive screw. | 831 screws | 2010-04-07 |
| Biomet Microfixation | 510(k) number | 2009-10-05 | Not classified | Process design | Biomet Microfixation is recalling 91-6103 1.5×3.5mm HT SD X-drive screw Lot Number 829760. This package may contain 91-6704 1.5x4mm ThinFlap SD X-drive screw. | 91 units | 2010-12-15 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.