GSR-TMP Combination Sensor (NC-C-GT)
NC-C-GT: The GSR sensor provides a measure of skin resistance or skin conductance when connected to a NeXus signal acquisition device, which is influenced by the autonomic activation of…
NC-C-GT: The GSR sensor provides a measure of skin resistance or skin conductance when connected to a NeXus signal acquisition device, which is influenced by the autonomic activation of sweat glands in the skin. The sensor output is not intended to be used for vital monitoring purposes. The temperature sensor provides a signal that corresponds with (variations in) peripheral skin temperature when connected to a NeXus signal acquisition device. The sensor shall be placed on intact skin to provide a signal that is influenced by cutaneous blood flow. The sensor is not intended to determine directly or indirectly a measure of core body temperature and to be used for vital monitoring purposes. The device is designed for medical use, not restricted to a specific medical indication, for acquisition of physiological signals. The device is intended to be used by, or under supervision of, a health professional within a clinical environment.
Who Else Makes It
Concentrated in Guangdong (5), Hebei (1).
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Shenzhen Dongdixin Technology Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 18 |
| Shenzhen Konmed Technology Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 8 |
| Shenzhen XFT Medical Limited | Shenzhen | Guangdong | Manufacturer | 8 |
| ISA Mould Engineering Limted | Dongguan | Guangdong | Contract manufacturer | 4 |
| Qinhuangdao Huisianpu Medical Systems Inc. | Qinhuangdao | Hebei | Manufacturer | 4 |
| Shuhai Jingwei(Shenzhen) Information Technology Co., Ltd. | Shenzhen | Guangdong | Manufacturer | 2 |
Record
| Listed by | Mind Media Europe B.V. |
|---|---|
| FDA product code | HCC |
| Device type | Device, Biofeedback |
| Device class | Class 2 |
| Regulation | 21 CFR 882.5050 |
| Premarket notification | Exempt |
| Record published | 2021-07-19 |
| Record revised | 2024-02-08 (version 2) |
Specifications
| MRI safety | MR Unsafe |
|---|---|
| Label carries | manufacturing date, serial number |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 1.0 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Ultium | Noraxon U.S.A., Inc. | 23 |
| FlexiCAP | Deymed Diagnostic S.R.O. | 16 |
| Ondamed | Ondamed Inc. | 15 |
| MyoPro | Myomo, Inc. | 12 |
| TeleMyo | Noraxon U.S.A., Inc. | 12 |
| Recording Cap G1 | Deymed Diagnostic S.R.O. | 8 |
| HAL for Medical Use | Cyberdyne Inc. | 8 |
| Disc Electrode 9mm Sn (Tin) | Deymed Diagnostic S.R.O. | 8 |
| Axon | Exsurgo Limited | 8 |
| Innara Health | Innara Health, Inc. | 7 |
| Kangaroo | Cardinal Health 200, LLC | 7 |
| SX230-1000 EMG Sensor | Biometrics Ltd. | 6 |
Showing 12 of 241. All products under Device, Biofeedback
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.