MicroPlex Compass Complex

38 catalogue numbers from 100355CMSR-V, listed by MicroVention, Inc., United States, under Device, Neurovascular Embolization. 5 manufacturers in China are registered for this product code.

Registry build 21.09.26
5manufacturers in China registered for this device type
38catalogue numbers in this listing
32510(k) clearances naming this product code
16recalls on this code

Who Else Makes It

Concentrated in Jiangsu (2), Shanghai (2), Guangdong (1). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code HCG
Manufacturer City Province Registered as Device types
Amphenol Alden Products Company Shenzhen Guangdong Contract manufacturer 24
Shanghai Wallaby Medical Technologies Co., Inc. Shanghai Shanghai Contract manufacturer 5
Steris Sterilization Technologies (Suzhou) Ltd Suzhou Jiangsu Contract manufacturer 44
Suzhou Prosteri Medical Technology Co., Ltd. Suzhou Jiangsu Contract manufacturer 20
Microport Neurotech (Shanghai) Co., Ltd. Shanghai Shanghai Manufacturer 2

Record

Regulatory record for MicroPlex Compass Complex
Listed by MicroVention, Inc., United States
FDA product code HCG
Device type Device, Neurovascular Embolization
Device class Class 2
Regulation 21 CFR 882.5950
Establishment Specification developer, Repacker / relabeller, Manufacturer, Exporter
Record published 2018-08-07
Record revised 2026-04-28 (version 6)

Specifications

Specifications
MRI safety MR Conditional
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Latex Labelled latex-free
Label carries lot or batch number, expiry date, manufacturing date
UDI direct marking Exempt

Catalogue Numbers

Catalogue numbers for MicroPlex Compass Complex
Catalogue number Size Status
100355CMSR-V 3.5 mm x 4.5 cm In distribution
100618CMSR-V 6 mm x 18 cm In distribution
181134CM-V 11 mm x 34 cm In distribution
181648CM-V 16 mm x 48 cm In distribution
180928CM-V 9 mm x 28 cm In distribution
180516CM-V 5 mm x 16 cm In distribution
100254CMSR-V 2.5 mm x 3.5 cm In distribution
100304CM-V 3 mm x 4 cm In distribution
100510CMSR-V 5 mm x 10 cm In distribution
100928CMSR-V 9 mm x 28 cm In distribution
181855CM-V 18 mm x 55 cm In distribution
181443CM-V 14 mm x 43 cm In distribution
100824CMSR-V 8 mm x 24 cm In distribution
100355CM-V 3.5 mm x 4.5 cm In distribution
100304CMSR-V 3 mm x 4 cm In distribution
180511CM-V 5 mm x 11 cm In distribution
100612CM-V 6 mm x 12 cm In distribution
100254CM-V 2.5 mm x 3.5 cm In distribution
181030CM-V 10 mm x 30 cm In distribution
100612CMSR-V 6 mm x 12 cm In distribution
100408CMSR-V 4 mm x 8 cm In distribution
180409CM-V 4 mm x 9 cm In distribution
180612CM-V 6 mm x 12 cm In distribution
100516CMSR-V 5 mm x 16 cm In distribution
100203CM-V 2 mm x 3 cm In distribution
182060CM-V 20 mm x 60 cm In distribution
100412CM-V 4 mm x 12 cm In distribution
100510CM-V 5 mm x 10 cm In distribution
100721CMSR-V 7 mm x 21 cm In distribution
181237CM-V 12 mm x 37 cm In distribution
180825CM-V 8 mm x 25 cm In distribution
100408CM-V 4 mm x 8 cm In distribution
180721CM-V 7 mm x 21 cm In distribution
100412CMSR-V 4 mm x 12 cm In distribution
100618CM-V 6 mm x 18 cm In distribution
101030CMSR-V 10 mm x 30 cm In distribution
180413CM-V 4 mm x 13 cm In distribution
100203CMSR-V 2 mm x 3 cm In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Optima Coil System Balt USA, LLC 307
Penumbra Coil 400 Penumbra Inc. 268
Smart Coil Penumbra Inc. 238
Axium™ Detachable Coil System Micro Therapeutics, Inc. 234
Numen Microport Neurotech (Shanghai) Co., Ltd. 223
Axium™ Prime Detachable Coil System Micro Therapeutics, Inc. 141
Barricade Coil System Balt USA, LLC 137
Numen Helia Microport Neurotech (Shanghai) Co., Ltd. 129
V-Trak MicroVention, Inc. 106
HydroSoft Helical MicroVention, Inc. 94
AxiumTM Micro Therapeutics, Inc. 89
LP Coil System Penumbra Inc. 77

Showing 12 of 99. All products under Device, Neurovascular Embolization

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K162999 2017-03-29
K161367 2016-08-31
K161452 2016-08-31
K153594 2016-01-22
K132952 2013-12-19
K131948 2013-10-04
K132317 2013-09-20
K120908 2012-04-25
K113457 2011-12-16
K112181 2011-12-01
K112226 2011-09-29
K111451 2011-09-20
K103758 2011-04-28
K100454 2010-04-22
K093919 2010-01-21
K093358 2010-01-15
K091641 2009-06-30
K090891 2009-06-22
K090357 2009-04-10
K090168 2009-03-12
K090001 2009-03-05
K082461 2008-10-02
K080666 2008-07-11
K070656 2007-06-15
K050954 2005-06-28
K041551 2004-07-07
K033836 2003-12-30
K032590 2003-10-22
K022735 2002-09-06
K020434 2002-07-29
K021914 2002-07-09
K012145 2001-10-29

Recalls

16 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2019-11-22 Class II Process design The devices may be missing the implant coil. 847 units 2022-01-26
2019-11-22 Class II Process design The devices may be missing the implant coil. 1,725 units 2022-01-26
2019-11-22 Class II Process design The devices may be missing the implant coil. 3,442 units 2022-01-26
2019-11-22 Class II Process design The devices may be missing the implant coil. 32 units 2022-01-26
2019-11-22 Class II Process design The devices may be missing the implant coil. 780 units 2022-01-26
2019-11-22 Class II Process design The devices may be missing the implant coil. 9 units 2022-01-26
2019-11-22 Class II Process design The devices may be missing the implant coil. 19 units 2022-01-26
2019-11-22 Class II Process design The devices may be missing the implant coil. 403 units 2022-01-26
2019-11-22 Class II Process design The devices may be missing the implant coil. 486 units 2022-01-26
2019-11-22 Class II Process design The devices may be missing the implant coil. 5,777 units 2022-01-26
2019-11-22 Class II Process design The devices may be missing the implant coil. 666 units 2022-01-26
2019-11-22 Class II Process design The devices may be missing the implant coil. 169 units 2022-01-26
2019-11-22 Class II Process design The devices may be missing the implant coil. 991 units 2022-01-26
2019-11-22 Class II Process design The devices may be missing the implant coil. 85 units 2022-01-26
2019-11-22 Class II Process design The devices may be missing the implant coil. 2,762 units 2022-01-26
2019-11-22 Class II Process design The devices may be missing the implant coil. 409 units 2022-01-26

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer