Fluid Monitoring Unit

The FDA filing identifies PS304 as the Fluid Monitoring Unit used with the GYN-Pump PH304 and explicitly calls it a component of that system. Its role is to measure fluid inflow for…

Registry build 21.09.26

The FDA filing identifies PS304 as the Fluid Monitoring Unit used with the GYN-Pump PH304 and explicitly calls it a component of that system.

Its role is to measure fluid inflow for fluid-deficit monitoring during hysteroscopy, using a separate weighing cell for fluid bags.

Monitoring Method

The submission says the PS304 weighing cell directly weighs the fluid bags to measure inflow volume. It reports a 6 percent accuracy for fluid-deficit measurement with this method.

1manufacturer
2catalogue numbers in this listing
10510(k) clearances naming this product code

Who Else Makes It

Registered in Jiangsu. One is registered as a contract manufacturer, able to build to a specification.

Chinese manufacturers registered for FDA product code HIG
Manufacturer City Province Registered as Device types
Peter’s Technology (Suzhou) Co., Ltd. Suzhou Jiangsu Contract manufacturer 9

Record

Regulatory record for Fluid Monitoring Unit
Listed by W.O.M. World of Medicine GmbH, United States
FDA product code HIG
Device type Insufflator, Hysteroscopic
Device class Class 2
Regulation 21 CFR 884.1700
510(k) K173489
Record published 2018-04-16
Record revised 2018-07-06 (version 2)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Prescription Prescription only
Label carries manufacturing date, serial number

Catalogue Numbers

Catalogue numbers for Fluid Monitoring Unit
Catalogue number Size Status
PS304 In distribution
PS304 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Tube set for irrigation, single-use W.O.M. World of Medicine GmbH 9
Insufflator, Hysteroscopic Karl Storz GmbH & Co. KG 7
Aquilex Fluid Control System W.O.M. World of Medicine GmbH 4
Aveta Smol Disposable Resecting Device, 2.9 mm Meditrina, Inc. 4
Tube set for suction, single-use W.O.M. World of Medicine GmbH 4
Premier Premier Dental Products Co. 3
Fluid Safe Stryker GmbH 3
Insufflator, Hysteroscopic Covidien LP 3
Hysteroscopic Fluid Management Smith & Nephew, Inc. 3
Aveta Disposable Resecting Handset Meditrina, Inc. 2
Fluent Fluid Management System Hologic, Inc. 2
Conmed ConMed Corporation 2

Showing 12 of 58. All products under Insufflator, Hysteroscopic

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K173489 2018-03-28
K172040 2018-02-05
K123732 2013-04-04
K112642 2012-02-06
K031616 2003-08-13
K022449 2003-04-10
K983889 1999-01-14
K934866 1995-10-20
K933847 1995-08-15
K924523 1995-04-11

Recalls Naming This Product

1 recall names this product by its own identifier, the 510(k) it is cleared under.

Recalls naming the identifiers of Fluid Monitoring Unit
Recalled by Identified by Initiated FDA class Root cause Reason Quantity
Novanta Medical GmbH 510(k) number 2021-06-18 Class II Software design When the display of inflow volume to the uterus reaches 32450 ml, the fluid management system control unit display will freeze because the internal software calculation threshold is reached. The outflow measurement will continue, and so the 1100

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer