VitaVitro
The filing names the VitaVitro single-lumen retrieval needle models ORNS-17G and ORNS-18G, and the double-lumen model ORND-17G. The named device is an oocyte retrieval needle. The filing…
The filing names the VitaVitro single-lumen retrieval needle models ORNS-17G and ORNS-18G, and the double-lumen model ORND-17G.
The named device is an oocyte retrieval needle. The filing describes use to aspirate oocytes during assisted reproduction procedures.
Device Function
The subject device description identifies single-lumen and double-lumen needle configurations. The double-lumen model is separately named as ORND-17G.
The device description lists the needle and its sleeve, handle, suction and vacuum catheters, and taper joint. It is supplied sterile and disposable.
Who Else Makes It
All of them in Guangdong.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Dongguan King Medical Technology Co., Ltd. | Dongguan | Guangdong | Contract manufacturer | 14 |
| Shenzhen VitaVitro Biotech Co., Ltd. | Shenzhen | Guangdong | Manufacturer | 7 |
| Gimbo Medical Technology Shenzhen Co., Ltd. | Shenzhen | Guangdong | Manufacturer | 3 |
Record
| Listed by | Shenzhen VitaVitro Biotech Co., Ltd., China |
|---|---|
| FDA product code | MQE |
| Device type | Needle, Assisted Reproduction |
| Device class | Class 2 |
| Regulation | 21 CFR 884.6100 |
| Establishment | Manufacturer |
| 510(k) | K240523 |
| Record published | 2024-12-06 |
| Record revised | 2025-02-19 (version 2) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| ORNS-17G | In distribution | |
| ORNS-18G | In distribution | |
| ORND-17G | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Cook | William A. Cook Australia PTY, Ltd. | 71 |
| Follicle Aspiration Set Single Lumen | Vitrolife Sweden AB | 40 |
| Follicle Aspiration Set, Double Lumen | Vitrolife Sweden AB | 28 |
| Wallace | ICU Medical, Inc | 20 |
| Kitazato OPU Needle with Connection Tube, Type2-v17 | Kitazato Corporation | 18 |
| Labotect | Labotect Labor-Technik Göttingen Gesellschaft mit beschränkter Haftung | 16 |
| Kitazato OPU Needle | Kitazato Corporation | 12 |
| Follicle Aspiration Set Reduced Single Lumen | Vitrolife Sweden AB | 11 |
| Follicle Aspiration Set Single Lumen, Luer | Vitrolife Sweden AB | 9 |
| Needle Guide | Civco Medical Instruments Co., Inc. | 8 |
| 17G Wallace Dual Lumen Oocyte Recovery Set | Coopersurgical, Inc. | 3 |
| ACE-M | Allwin Medical Devices, Inc. | 3 |
Showing 12 of 65. All products under Needle, Assisted Reproduction
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K240523 | 2024-11-15 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.