IVF Pasteur Pipets
Origio, Inc. 5.75" (14.6 cm) IVF Pasteur Pipets
Who Else Makes It
Concentrated in Guangdong (8), Hubei (1), Shandong (1). One is registered as a contract manufacturer, able to build to a specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Shenzhen Boomingshing Medical Device Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 5 |
| Shenzhen JPY ION-Tech. Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 20 |
| Dongguan King Medical Technology Co., Ltd. | Dongguan | Guangdong | Contract manufacturer | 14 |
| Wuhan Huchuang Union Technology Co., Ltd. | Wuhan | Hubei | Manufacturer | 8 |
| Shenzhen VitaVitro Biotech Co., Ltd. | Shenzhen | Guangdong | Manufacturer | 7 |
| HUA YUE Medical Technology Co., Ltd. | Guangzhou | Guangdong | Manufacturer | 7 |
| CGN Gray (Shenzhen) Technology Co., Ltd. | Shenzhen | Guangdong | Contract manufacturer | 5 |
| Gimbo Medical Technology Shenzhen Co., Ltd. | Shenzhen | Guangdong | Manufacturer | 3 |
| Guangzhou Hehong Biotech Co., Ltd. | Guangzhou | Guangdong | Manufacturer | 2 |
| Shandong Wego Ruisheng Medical Device Co., Ltd. | Weihai | Shandong | Manufacturer | 2 |
Record
| Listed by | Coopersurgical, Inc., United States |
|---|---|
| FDA product code | MQK |
| Device type | Labware, Assisted Reproduction |
| Device class | Class 2 |
| Regulation | 21 CFR 884.6160 |
| Establishment | Contract manufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer |
| 510(k) | K000915 |
| Record published | 2016-09-23 |
| Record revised | 2024-02-28 (version 6) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date, manufacturing date |
| Packaging | Pack of 30, box of 20, pack of 20 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| PP-9-90 | In distribution | |
| PP-5.75-90 | In distribution | |
| PP-5.75-1000 | In distribution | |
| PP-9-1000 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Cryotec | Reprolife Inc. | 20 |
| VitriGuard | Origio A/S | 16 |
| G-Vitri™ Vitrification Straw | Gimbo Medical Technology Shenzhen Co., Ltd. | 15 |
| ZyMot | DxNow Inc. | 10 |
| LensHooke Sperm Separation Device | Bonraybio Co., Ltd. | 9 |
| cryo-GO Vitrification Device | Fujifilm Irvine Scientific | 9 |
| LifeGlobal® GPS® Dishware | Coopersurgical, Inc. | 7 |
| LifeGlobal® GPS® Dishware | LifeGlobal Group, LLC | 7 |
| Nest VT | Cook Incorporated | 5 |
| Surestrip | Allwin Medical Devices, Inc. | 5 |
| Minvitro Vitrification Straw | Guangzhou Hehong Biotech Co., Ltd. | 5 |
| Rapid-i Kit | Vitrolife Sweden AB | 5 |
Showing 12 of 102. All products under Labware, Assisted Reproduction
Recalls Naming This Product
2 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Coopersurgical, Inc. | 510(k) number | 2014-06-20 | Class II | Package design/selection | Identification of packaging breach of the nylon pouch sterile barrier for the 3-pack configuration | Total number of Boxes Distributed 32,760. US 4,093 / Canada | 2015-07-20 |
| Coopersurgical, Inc. | 510(k) number | 2007-05-08 | Not classified | Other | Pasteur pipettes for laboratory use were labeled as sterile but may have become contaminated. | 160 boxes | 2007-10-29 |
Recalls
1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2022-04-01 | Class II | Process control | Products in this lot may have compromised barrier seals, introducing a risk to sterility. | 2,340 (US only) | |
| 2011-11-28 | Not classified | Device Design | Cryopettes were rupturing during the warming process following vitrification. | 73850 Cryopettes | 2013-02-04 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.