Meridian M110 Fetal Monitoring System

The MERIDIAN M110 Fetal Monitoring System is an intrapartum fetal monitor that externally measures and displays fetal heart rate (FHR), maternal heart rate (MHR), and uterine contractions…

Registry build 21.09.26

The MERIDIAN M110 Fetal Monitoring System is an intrapartum fetal monitor that externally measures and displays fetal heart rate (FHR), maternal heart rate (MHR), and uterine contractions (UA). The MERIDIAN M110 Fetal Monitoring System acquires and displays the FHR and UA from abdominal surface electrodes that detect the fetal ECG signals, maternal ECG signals, and of uterine muscle contraction signals.

6manufacturers in China registered for this device type
1catalogue number
3510(k) clearances naming this product code

Who Else Makes It

Concentrated in Guangdong (4), Jiangsu (1), Shandong (1). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code HGM
Manufacturer City Province Registered as Device types
Amphenol Medical Technologies (Dongguan) Co., Ltd. Dongguan Guangdong Contract manufacturer 77
Luen Hing Textile -Shangyu Manufacturing(ZHONG Shan) Co Ltd Zhongshan Guangdong Contract manufacturer 2
GE Medical Systems (China) Co., Ltd. Wuxi Jiangsu Contract manufacturer 57
Edan Instruments, Inc. Shenzhen Guangdong Contract manufacturer 56
Orantech Inc. Shenzhen Guangdong Contract manufacturer 40
China Qingdao Bright Medical Manufacturing Co., Ltd. Qingdao Shandong Contract manufacturer 8

Record

Regulatory record for Meridian M110 Fetal Monitoring System
Listed by Mindchild Medical, United States
FDA product code HGM
Device type System, Monitoring, Perinatal
Device class Class 2
Regulation 21 CFR 884.2740
Premarket notification Exempt
Record published 2017-06-06
Record revised 2022-11-28 (version 3)

Specifications

Specifications
MRI safety MR Unsafe
Prescription Prescription only
Label carries serial number
Packaging Mixed case

Catalogue Numbers

Catalogue numbers for Meridian M110 Fetal Monitoring System
Catalogue number Size Status
M110 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
R&D Batteries, Inc. R & D Batteries, Inc. 137
Sonicaid Huntleigh Healthcare Ltd. 39
Obix Huntleigh Healthcare Ltd. 33
Ameritus Transducer Kentec Medical, LLC 28
Fetal Monitor Remote Display Clinicomp Intl., Inc. 18
Tenacore Tenacore LLC 11
FetaLink Cerner Corporation 9
PeriWatch Vigilance® HUB™ PeriGen Solutions Ltd. 9
Dopplex Huntleigh Healthcare Ltd. 9
Mini Telemetry System Wipro GE Healthcare Private Ltd. 8
Natus Neurology Natus Neurology Incorporated 8
Fetal & maternal monitor Edan Instruments, Inc. 8

Showing 12 of 117. All products under System, Monitoring, Perinatal

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K161902 2017-01-12
K142883 2015-04-17
K120018 2012-09-19

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer