Leep Radius Electrode

LEEP Radius Electrode; 2.0cm x 1.0cm; 12cm Shaft

Registry build 21.09.26
6manufacturers in China registered for this device type
10catalogue numbers in this listing
1510(k) clearance
22recalls on this code

Who Else Makes It

Concentrated in Guangdong (3), Zhejiang (3). 3 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code HGI
Manufacturer City Province Registered as Device types
Modern Medical Equipment Manufacturing Ltd. Heng Li, Dongguan Guangdong Contract manufacturer 26
Zhejiang Shuyou Surgical Instrument Co., Ltd. Huzhou Zhejiang Contract manufacturer 13
Ningbo Shun YE Medical Company, Ltd. Cixi Ningbo Zhejiang Contract manufacturer 8
Modern Medical Equipment Manufacturing (Qing Yuan) Ltd Qing Yuan Guangdong Contract manufacturer 26
Shenzhen JPY ION-Tech. Co., Ltd. Shenzhen Guangdong Contract manufacturer 20
Zhejiang Jinhua Huatong Medical Appliance Co., Ltd. Jinhua Zhejiang Manufacturer 4

Record

Regulatory record for Leep Radius Electrode
Listed by Coopersurgical, Inc., United States
FDA product code HGI
Device type Electrocautery, Gynecologic (And Accessories)
Device class Class 2
Regulation 21 CFR 884.4120
Establishment Contract manufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer
510(k) K905747
Record published 2016-08-15
Record revised 2024-02-28 (version 6)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date
Packaging Pack of 5

Catalogue Numbers

Catalogue numbers for Leep Radius Electrode
Catalogue number Size Status
R2010 In distribution
R2008 In distribution
R2015 In distribution
R2510 In distribution
R1515 In distribution
R1010 In distribution
R1007 In distribution
R1505 In distribution
R2020 In distribution
R1507 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Bovie Aspen Surgical Products, Inc. 138
DeRoyal Deroyal Industries, Inc. 27
Electrocautery, Gynecologic (And Accessories) C R I 24
Greenwald Surgical Company, Inc. Grace Manufacturing Inc 22
Valleylab Aspen Surgical Products, Inc. 20
Argent Mckesson Medical-Surgical Inc. 19
Carrera Loop Electrodes Gynex Corporation 19
Weck Teleflex Medical LLC 18
Radius Loop ELectrodes Gynex Corporation 13
Aesculap Aesculap AG 11
Premier Premier Dental Products Co. 9
Megadyne Megadyne Medical Products, Inc. 9

Showing 12 of 70. All products under Electrocautery, Gynecologic (And Accessories)

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K952483 1995-10-06

Recalls Naming This Product

1 recall names this product by its own identifier, the 510(k) it is cleared under.

Recalls naming the identifiers of Leep Radius Electrode
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Coopersurgical, Inc. 510(k) number 2014-10-27 Class II Packaging process control Outer box is mislabeled as P/N R2010- Large Radius Loop Electrode instead of P/N R1010- Medium Radius Loop Electrode 595 units 2015-05-29

Recalls

13 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2021-09-29 Class II Component design/selection Coagulate function may not operate with the use of the Hand Switch, failure of the device to coagulate tissue may lead to a prolonged procedure requiring medical intervention to control any intraoperative bleeding and complete the case. 1587 Units
2021-09-29 Class II Component design/selection Coagulate function may not operate with the use of the Hand Switch, failure of the device to coagulate tissue may lead to a prolonged procedure requiring medical intervention to control any intraoperative bleeding and complete the case. 193 Units
2021-09-29 Class II Component design/selection Coagulate function may not operate with the use of the Hand Switch, failure of the device to coagulate tissue may lead to a prolonged procedure requiring medical intervention to control any intraoperative bleeding and complete the case. 244 Units
2021-09-29 Class II Component design/selection Coagulate function may not operate with the use of the Hand Switch, failure of the device to coagulate tissue may lead to a prolonged procedure requiring medical intervention to control any intraoperative bleeding and complete the case. 700 Units
2021-09-29 Class II Component design/selection Coagulate function may not operate with the use of the Hand Switch, failure of the device to coagulate tissue may lead to a prolonged procedure requiring medical intervention to control any intraoperative bleeding and complete the case. 75 Units
2021-09-29 Class II Component design/selection Coagulate function may not operate with the use of the Hand Switch, failure of the device to coagulate tissue may lead to a prolonged procedure requiring medical intervention to control any intraoperative bleeding and complete the case. 75 Units
2021-09-29 Class II Component design/selection XXX 154 Units
2019-10-16 Class II Device Design Potential for the Quantum 2000 Electrosurgery Generator, part numbers 909075, 909075-05 and 909075-05W, to cease to either cut, coagulate, or blend during a procedure when the foot pedal is used for activation. 110 2020-06-30
2019-10-16 Class II Device Design Potential for the Quantum 2000 Electrosurgery Generator, part numbers 909075, 909075-05 and 909075-05W, to cease to either cut, coagulate, or blend during a procedure when the foot pedal is used for activation. 105 2020-06-30
2019-10-16 Class II Device Design Potential for the Quantum 2000 Electrosurgery Generator, part numbers 909075, 909075-05 and 909075-05W, to cease to either cut, coagulate, or blend during a procedure when the foot pedal is used for activation. 4 2020-06-30
2019-06-18 Class II Device Design The products’ cut, coagulate, or blend function may not operate with the use of the Foot Pedal. 358 2020-06-15
2019-04-23 Class II Process control 2.5A slow blow fuses may have been installed in the LEEP RPECISION Generator rather than the appropriate 3.15A slow blow fuses. 19 2020-04-24
2018-03-12 Class II Under Investigation by firm Products have been packaged with an incorrect product size. 500 2019-05-08
2006-03-10 Not classified Other Change in product material may be cause for wire breaking, and tip burning and melting during procedure. Broken pieces of the device may need to be retrieved from patient. 831.0 boxes 2016-03-07
2006-03-10 Not classified Other Change in product material may be cause for wire breaking, and tip burning and melting during procedure. Broken pieces of the device may need to be retrieved from patient. 129.0 boxes (10 each) 2016-03-07
2006-03-10 Not classified Other Change in product material may be cause for wire breaking, and tip burning and melting during procedure. Broken pieces of the device may need to be retrieved from patient. 1,845.0 boxes 2016-03-07
2006-03-10 Not classified Other Change in product material may be cause for wire breaking, and tip burning and melting during procedure. Broken pieces of the device may need to be retrieved from patient. 2,813.0 boxes 2016-03-07
2006-03-10 Not classified Other Change in product material may be cause for wire breaking, and tip burning and melting during procedure. Broken pieces of the device may need to be retrieved from patient. 129 boxes (10 each) 2016-03-07
2006-03-10 Not classified Other Change in product material may be cause for wire breaking, and tip burning and melting during procedure. Broken pieces of the device may need to be retrieved from patient. 818.0 boxes 2016-03-07
2006-03-10 Not classified Other Change in product material may be cause for wire breaking, and tip burning and melting during procedure. Broken pieces of the device may need to be retrieved from patient. 1,232.0 boxes 2016-03-07
2006-03-10 Not classified Other Change in product material may be cause for wire breaking, and tip burning and melting during procedure. Broken pieces of the device may need to be retrieved from patient. 1,602.7 boxes 2016-03-07

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer