Abbi

The filing names ABBI as the Air Bubble Based Infuser and describes it as a dual barrel syringe connected to an intrauterine catheter to instill saline air contrast during SonoHSG. It also…

Registry build 21.09.26

The filing names ABBI as the Air Bubble Based Infuser and describes it as a dual barrel syringe connected to an intrauterine catheter to instill saline air contrast during SonoHSG.

It also describes saline infusion through an intrauterine catheter for saline infusion sonography, abbreviated SIS.

Listed Item

ABBI™ KIT (Air Bubble Based Infuser) For office based Sono HSG Procedures

Stated Procedures

For SonoHSG, the stated use is a continuous stream of alternating saline and air contrast media into the uterus and fallopian tubes with an intrauterine catheter. For SIS, saline is instilled into the uterus as a continuous stream.

5manufacturers in China registered for this device type
2catalogue numbers in this listing
4510(k) clearances naming this product code
8recalls on this code

Who Else Makes It

Concentrated in Guangdong (2), Zhejiang (2), Beijing (1). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code LKF
Manufacturer City Province Registered as Device types
Modern Medical Equipment Manufacturing Ltd. Heng Li, Dongguan Guangdong Contract manufacturer 26
Tonglu Qianyan Medtech Co., Ltd. Hangzhou Zhejiang Contract manufacturer 7
Modern Medical Equipment Manufacturing (Qing Yuan) Ltd Qing Yuan Guangdong Contract manufacturer 26
Zhejiang Huanyi Sterilization Technology Co., Ltd. Huzhou Zhejiang Contract manufacturer 25
Beijing Hangtian Kadi Technology R&D Institute Beijing Beijing Manufacturer 5

Record

Regulatory record for Abbi
Listed by Coopersurgical, Inc., United States
FDA product code LKF
Device type Cannula, Manipulator/Injector, Uterine
Device class Class 2
Regulation 21 CFR 884.4530
Establishment Contract manufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer
510(k) K143415
Record published 2016-09-06
Record revised 2024-02-28 (version 5)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Supplied as a kit Yes
Latex Labelled latex-free
Label carries lot or batch number, expiry date

Catalogue Numbers

Catalogue numbers for Abbi
Catalogue number Size Status
ABBI-KIT In distribution
ABBI In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Elmed Elmed, Inc. 39
Cannula, Manipulator/Injector, Uterine C R I 31
Marina Medical Marina Medical Instruments, Inc. 29
HSG Catheter Titus Medical LLC 26
HNM Women Care HNM Stainless, LLC. 20
Bioteque Bioteque Taiwan Ltd. 16
Viky Endocontrol 15
Cannula, Manipulator/Injector, Uterine Panpac Medical Corporation 14
Uterine ElevatOR Pro THE O R Company PTY Ltd 12
Valtchev Uterine Mobilizer Conkin Surgical Instruments Ltd. 10
Novo Surgical Novo Surgical, Inc. 9
McCarus-Volker Fornisee® System LSI Solutions Inc. 9

Showing 12 of 111. All products under Cannula, Manipulator/Injector, Uterine

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K223064 2022-10-28
K153092 2015-12-21
K143415 2015-02-26
K141523 2014-11-25

Recalls

8 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2022-03-31 Class II Component design/selection Incorrect bonding material used for assembly of the catheter, may fail, resulting in detachment of component parts, broken components, or leakage. This breakage may result in delay of procedure 169 units
2022-03-31 Class II Component design/selection Incorrect bonding material used for assembly of the catheter, may fail, resulting in detachment of component parts, broken components, or leakage. This breakage may result in delay of procedure 73 units
2022-03-31 Class II Component design/selection Incorrect bonding material used for assembly of the catheter, may fail, resulting in detachment of component parts, broken components, or leakage. This breakage may result in delay of procedure 90 units
2015-05-18 Class II Device Design Design of device may expose user to injury to fingers or body parts 5 units 2015-08-07
2014-07-03 Class II Packaging process control Unsealed pouches. 1,400 units 2015-05-28
2014-05-13 Class II Process control Sterility of the device may be compromised due to unsealed pouch 1180 units 2015-05-28
2012-10-31 Class II Device Design Excessive pressure exerted on the uterine tip when attached to the Arch may, under certain circumstances, cause the internal steel rod of the tip to protrude through the cleaning hole on the shaft of the handle 1215 total 2014-03-04
2012-10-31 Class II Device Design Excessive pressure exerted on the uterine tip when attached to the Arch may, under certain circumstances, cause the internal steel rod of the tip to protrude through the cleaning hole on the shaft of the handle 1215 total 2014-03-04

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer