Mckesson
Gynecath H/S Catheter 5FR (10/
5manufacturers in China registered for this device type
2catalogue numbers in this listing
Who Else Makes It
Concentrated in Guangdong (2), Zhejiang (2), Beijing (1). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Modern Medical Equipment Manufacturing Ltd. | Heng Li, Dongguan | Guangdong | Contract manufacturer | 26 |
| Tonglu Qianyan Medtech Co., Ltd. | Hangzhou | Zhejiang | Contract manufacturer | 7 |
| Modern Medical Equipment Manufacturing (Qing Yuan) Ltd | Qing Yuan | Guangdong | Contract manufacturer | 26 |
| Zhejiang Huanyi Sterilization Technology Co., Ltd. | Huzhou | Zhejiang | Contract manufacturer | 25 |
| Beijing Hangtian Kadi Technology R&D Institute | Beijing | Beijing | Manufacturer | 5 |
Record
| Listed by | Mckesson Medical-Surgical Inc. |
|---|---|
| FDA product code | LKF |
| Device type | Cannula, Manipulator/Injector, Uterine |
| Device class | Class 2 |
| Regulation | 21 CFR 884.4530 |
| 510(k) | K961752 |
| Record published | 2020-08-10 |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date |
| Packaging | Box, case of 10 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 11-19610 | In distribution | |
| 11-19611 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Elmed | Elmed, Inc. | 39 |
| Cannula, Manipulator/Injector, Uterine | C R I | 31 |
| Marina Medical | Marina Medical Instruments, Inc. | 29 |
| HSG Catheter | Titus Medical LLC | 26 |
| HNM Women Care | HNM Stainless, LLC. | 20 |
| Bioteque | Bioteque Taiwan Ltd. | 16 |
| Viky | Endocontrol | 15 |
| Cannula, Manipulator/Injector, Uterine | Panpac Medical Corporation | 14 |
| Uterine ElevatOR Pro | THE O R Company PTY Ltd | 12 |
| Valtchev Uterine Mobilizer | Conkin Surgical Instruments Ltd. | 10 |
| Novo Surgical | Novo Surgical, Inc. | 9 |
| McCarus-Volker Fornisee® System | LSI Solutions Inc. | 9 |
Showing 12 of 111. All products under Cannula, Manipulator/Injector, Uterine
Recalls Naming This Product
2 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|---|---|
| Mckesson Medical-Surgical Inc. Corporate Office | 510(k) number | 2022-05-25 | Class II | Environmental control | Facility Temperature excursions (from June 2021-August 2021) prior to delivery; exposure to higher temperatures may have impacted product effectiveness. All lots received between 06/01/21-9/30/21. | a. 30 each b. 0.3 cs |
| Coopersurgical, Inc. | 510(k) number | 2022-03-31 | Class II | Component design/selection | Incorrect bonding material used for assembly of the catheter, may fail, resulting in detachment of component parts, broken components, or leakage. This breakage may result in delay of procedure | 73 units |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.