The Stork® OTC packages include: Instructions for Use (IFU), one Conceptacle® and one plastic applicator. Once the couple has decided to attempt to become pregnant, the Stork® OTC…
The Stork® OTC packages include: Instructions for Use (IFU), one Conceptacle® and one plastic applicator. Once the couple has decided to attempt to become pregnant, the Stork® OTC Conception System Instruction for Use recommends using the device during female’s most fertile days in a given month. During sexual intercourse, semen will be collected using the Conceptacle®, a cervical cap that is pre-inserted into a condom-like sheath. The male removes the Conceptacle® from the penis by rolling it down and separating it from the penis. After removal, the rim of the cervical cap is lightly pinched so that the Condom-like Sheath can be separated. (The Cervical Cap and Condom-like Sheath are separated in two separate parts). The semen is contained in the cervical cap and its reservoir. The second component, the Applicator, is used for ease of transition of the Cervical Cap to the cervix. The applicator seals the Cervical Cap and contains the semen for transition through the vaginal tract, assisting the female in guiding the cap to the cervix and releasing the semen and the cap in front of the cervix. When the cervical cap is loaded onto the applicator (while it is still outside of the body), the Retainer locks onto the Cervical Cap and is delivered with the Cervical Cap intra-vaginally. The Retainer also has a removal cord that is attached for withdrawal. The Cervical Cap and Retainer then remain in place for up to 6 hours.
Who Else Makes It
Registered in Guangdong. One is registered as a contract manufacturer, able to build to a specification.
Record
Regulatory record for The Stork OTC | Listed by | Stork IB2C, Inc., THE |
| FDA product code | OBB |
| Device type | Kit, Conception-Assist, Home Use |
| Device class | Class 2 |
| Regulation | 21 CFR 884.5250 |
| 510(k) | K140186 |
| Record published | 2017-10-11 |
| Record revised | 2018-07-06 (version 3) |
Specifications
Specifications | MRI safety | Labeling does not contain MRI Safety Information |
| Supplied sterile | Yes |
| Single use | Yes |
| Over the counter | Yes |
| Supplied as a kit | Yes |
| Latex | Labelled latex-free |
| Label carries | lot or batch number, expiry date, manufacturing date |
| Storage | Special storage condition: Keep Away from Sunlight; Special storage condition: Keep Dry; Storage environment temperature -30 to 54 °C |