Kowa Nonmyd WX

KOWA nonmyd WX is a retinal camera that captures standard and stereo photographs without medication to dilate the pupil. It combines a camera body with an external digital single lens…

Registry build 21.09.26

KOWA nonmyd WX is a retinal camera that captures standard and stereo photographs without medication to dilate the pupil. It combines a camera body with an external digital single lens reflex camera for image capture.

An infrared LED illuminates the eye during observation, and a xenon flash supplies light for photography. The camera captures the pair of stereo images simultaneously in a single shot, avoiding a separate exposure for each view.

Listed Item

KOWA nonmyd WX is intended for use with plane and stereo retinal image capturing without mydriatic. The retina image can be stored to an image filing derive through serial interface.

Image Handling

A USB port transfers images to a computer, and the camera can connect to the KOWA portable VK-2 image filing system. Standard retinal photography can be performed when the pupil diameter is greater than 3.7 mm.

3manufacturers in China registered for this device type
1catalogue number
14510(k) clearances naming this product code

Who Else Makes It

Concentrated in Jiangsu (1), Shanghai (1), Chongqing (1). One is registered as a contract manufacturer, able to build to a specification.

Chinese manufacturers registered for FDA product code HKI
Manufacturer City Province Registered as Device types
Shanghai Mediworks Precision Instruments Co., Ltd. Shanghai Shanghai Contract manufacturer 13
Taizhou City K&W International Trade Co., Ltd. Jiangyan Jiangsu Repacker / relabeller 38
Chongqing BIO Newvision Medical Equipment Ltd. Chongqing Chongqing Manufacturer 2

Record

Regulatory record for Kowa nonmyd WX
Listed by Kowa Co., Ltd., Japan
FDA product code HKI
Device type Camera, Ophthalmic, Ac-Powered
Device class Class 2
Regulation 21 CFR 886.1120
510(k) K101628
Record published 2016-09-16
Record revised 2018-07-06 (version 3)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Prescription Prescription only
Label carries serial number
Storage Storage environment temperature -15 to 55 °C; Storage environment humidity 10 to 95 % RH; Handling environment temperature 10 to 35 °C; Handling environment humidity 30 to 90 % RH
Sizes Height 548 mm; depth 504 mm; width 310 mm; weight 21 kg

Catalogue Numbers

Catalogue numbers for Kowa nonmyd WX
Catalogue number Size Status
K9L57FK Height 548 mm In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Jedmed Jedmed Instrument Company 15
Neolight Neolight, LLC 11
Natus Xltek 6
RetCam Envision Natus Medical Denmark ApS 6
3nethra Forus Health Pvt.ltd., 6
iCam Optovue, Inc. 5
iFusion Optovue, Inc. 5
Canon Inc. Canon Inc. 4
Camera, Ophthalmic, Ac-Powered Chongqing Kanghuaruiming S&T Co., Ltd.. 4
3D Optical Coherence Tomography 3D OCT-1(Type:Maestro2) Topcon Corp. 3
Retinal Camera TRC-50DX Topcon Corp. 3
NON-Mydriatic Retinal Camera TRC-NW400 Topcon Corp. 2

Showing 12 of 123. All products under Camera, Ophthalmic, Ac-Powered

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K191945 2019-09-10
K190573 2019-06-04
K112330 2012-02-16
K101628 2011-01-26
K091098 2009-08-07
K091683 2009-07-02
K083387 2009-01-16
K082767 2008-10-21
K080681 2008-04-04
K062021 2006-11-01
K062356 2006-09-27
K053026 2005-11-10
K050271 2005-11-03
K043213 2005-10-06

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer