Refractor

The NIDEK REFRACTOR Model RT-3100 is a computerized refractor used for subjective refraction with the NIDEK AUTO REFRACTOMETER (AR), AUTO REF/KERATOMETER (ARK), AUTO REF/ KER/TONOMETER…

Registry build 21.09.26

The NIDEK REFRACTOR Model RT-3100 is a computerized refractor used for subjective refraction with the NIDEK AUTO REFRACTOMETER (AR), AUTO REF/KERATOMETER (ARK), AUTO REF/ KER/TONOMETER (RKT), or AUTO LENSMETER (LM) via Eye Care card. The RT-3100 includes a refractor head, control box, and relay box. The relay box not only connects the other two units, but also connects the Chart Presenting device or PC. The control box includes the key panel, display, and printer. The display is a touch-screen panel. The control box displays the data and can be used for almost all operations. In addition, the control box operates the refractor head and the connected chart presenting device. It allows the refractor and charts to be controlled together. Normally, the relay box is installed on the system table (not included in the RT-3100 package.)

15manufacturers in China registered for this device type
3catalogue numbers in this listing
3recalls on this code

Who Else Makes It

Concentrated in Jiangsu (5), Shanghai (3), Zhejiang (2). 4 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code HKN
Manufacturer City Province Registered as Device types
Wuxi Zontai Int’l Corporation Ltd. Wuxi Jiangsu Contract manufacturer 22
Taiyuan North China Xinyuan Tech. Center (Co., Ltd.) Taiyuan Shaanxi Contract manufacturer 14
Chongqing Yeasn Science-Technology Co., Ltd. Chongqing Chongqing Contract manufacturer 5
Langfang FAR East Prosperous Optical Instrument Co., Ltd. Langfang Hebei Contract manufacturer 5
Beijing Hongdee Corporation Beijing Beijing Private-label distributor 43
Danyang NEW Hope Medical Equipment Co., Ltd. Danyang Jiangsu Manufacturer 38
Taizhou City K&W International Trade Co., Ltd. Jiangyan Jiangsu Repacker / relabeller 38
Lianyungang Tiannuo Optical Instrument Co., Ltd. Lianyungang Jiangsu Contract manufacturer 31
Shanghai Link Instruments Co., Ltd. Changzhou Jiangsu Manufacturer 21
Gino Optical (Shanghai) Co., Ltd. Shanghai Shanghai Manufacturer 15
Shanghai Canton Optics Equipment Co., Ltd. Shanghai Shanghai Manufacturer 14
Ningbo Ming Sing Optical R&D Co., Ltd. Ningbo Zhejiang Repacker / relabeller 9

Showing 12 of 15. All 15 manufacturers in China registered for Refractor, Manual, Non-Powered, Including Phoropter

Record

Regulatory record for Refractor
Listed by Nidek Incorporated, United States
FDA product code HKN
Device type Refractor, Manual, Non-Powered, Including Phoropter
Device class Class 1
Regulation 21 CFR 886.1770
Establishment Specification developer, Manufacturer
Premarket notification Exempt
Record published 2023-06-12
Record revised 2020-12-21 (version 3)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Prescription Prescription only
Label carries serial number

Catalogue Numbers

Catalogue numbers for Refractor
Catalogue number Size Status
RT-600 In distribution
RT-3100 In distribution
RT-5100 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Yeasn Chongqing Yeasn Science-Technology Co., Ltd. 9
Moptim Shenzhen Certainn Technology Co., Ltd. 4
S4Optik Innova Medical Ophthalmics 3
Lombart Innova Medical Ophthalmics 3
Vision-R 700 Essilor International 2
Phoropter VRx Reichert Inc. 2
Power Supply Unit for CV-5000 (Built-IN PC Type) Topcon Corp. 2
Compu Vision CV-5000 Topcon Corp. 2
Illuminated Phoropter Reichert Inc. 2
Vision-R 800 Essilor International 2
Visionix Luneau Technology Operations 2
Eli Ezer U.S. Ophthalmic, L.L.C. 2

Showing 12 of 40. All products under Refractor, Manual, Non-Powered, Including Phoropter

Recalls

2 of these are Class II. Class II means a temporary or reversible health consequence. Class III is unlikely to cause harm at all → typically a labelling or documentation fault. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2018-06-14 Class III Employee error The lens bonding was incomplete on the refractor. 85 instruments 2020-06-03
2016-02-29 Class II Component design/selection There has been a reoccurrence of an issue on the RT 5100 and RT 3100 Refractor of the Near Point Chart Arm lowering spontaneously with potential for slight injury to face or nose of patient. 2703 separate serial numbers 2018-09-24
2014-06-09 Class II Use error Near Point Chart Arm of RT 5100 and RT-3100 Refractors may lower spontaneously with potential for patient injury. ~4,285 units RT-5100; 167 units of RT-3100 2015-10-30

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer