AT 030

The AT 030 measures intraocular pressure using the Goldmann applanation method, supporting assessment and management of glaucoma. It is a mechanical contact tonometer used with a compatible…

Registry build 21.09.26

The AT 030 measures intraocular pressure using the Goldmann applanation method, supporting assessment and management of glaucoma. It is a mechanical contact tonometer used with a compatible Zeiss slit lamp.

A measuring prism contacts the cornea while the user observes the flattened area through the slit-lamp microscope. Turning the graduated drum changes the applied force, and the indicated value is converted to eye pressure using the supplied conversion table.

Listed Item

The AT 030 is an appliance that serves to measure intraocular pressure, according to the Goldman method. Assessment of IOP may contribute to the diagnosis, and aid in the management of glaucoma.

Prism and Mounting

The prism incorporates an optical doubling system and attaches through an extending holder. Compatible slit lamps include the Zeiss SL 120, SL 130 and SL 220, as well as the specified LSL Visulas configurations.

5manufacturers in China registered for this device type
1catalogue number
1510(k) clearance

Who Else Makes It

Concentrated in Jiangsu (2), Beijing (1), Shanghai (1).

Chinese manufacturers registered for FDA product code HKY
Manufacturer City Province Registered as Device types
Beijing Hongdee Corporation Beijing Beijing Private-label distributor 43
Taizhou City K&W International Trade Co., Ltd. Jiangyan Jiangsu Repacker / relabeller 38
Lianyungang Tiannuo Optical Instrument Co., Ltd. Lianyungang Jiangsu Contract manufacturer 31
Shanghai Mediworks Precision Instruments Co., Ltd. Shanghai Shanghai Contract manufacturer 13
Chongqing Sunkingdom Medical Instrument Co., Ltd. Chongqing Chongqing Manufacturer 11

Record

Regulatory record for AT 030
Listed by Carl Zeiss Meditec Inc, United States
FDA product code HKY
Device type Tonometer, Manual
Device class Class 2
Regulation 21 CFR 886.1930
Establishment Contract manufacturer, Specification developer, Repacker / relabeller, Manufacturer
510(k) K180839
Record published 2018-12-04
Record revised 2026-01-14 (version 4)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Prescription Prescription only
Label carries manufacturing date, serial number
Storage Storage environment temperature -40 to 70 °C; Storage environment humidity 10 to 95 % RH; Special storage condition: Storage w/o packaging: temperature -10°C to +55°C; rel. humidity 10%-95%

Catalogue Numbers

Catalogue numbers for AT 030
Catalogue number Size Status
AT 030 AT 030 for SL 120, SL 130 and SL 220: 105 mm x 40 mm x 25 mm In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Tonometer AT 900 Haag-Streit AG 7
Ambler Surgical Ambler Surgical, LLC 7
Ocu-Film® +” Reichert Inc. 5
Bausch + Lomb Bausch & Lomb Incorporated 5
AccuTip Cover Accutome, Inc. 4
Mediworks Shanghai Mediworks Precision Instruments Co., Ltd. 4
Applanation Tonometer Chongqing Sunkingdom Medical Instrument Co., Ltd. 3
Icare ic200 Icare Finland Oy 3
Marco Takagi Seiko Co., Ltd. 2
S4 Optik Costruzioni Strumenti Oftalmici C.S.O. SRL 2
iCare PATIENT2 Icare Finland Oy 2
Tonometer AT 870 Haag-Streit AG 2

Showing 12 of 71. All products under Tonometer, Manual

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K180839 2018-06-07

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer