Ocu-Dot® Tonometer Probes – 100 Count
The Ocu-Dot Tonometer Probe is the disposable contact accessory used by the Reichert Tono-Vera tonometer to measure intraocular pressure. It is required for both the standard-battery and…
The Ocu-Dot Tonometer Probe is the disposable contact accessory used by the Reichert Tono-Vera tonometer to measure intraocular pressure. It is required for both the standard-battery and rechargeable Tono-Vera models.
The tonometer propels the small plastic-tipped probe toward the unanaesthetised cornea in a controlled movement. It detects and analyses the probe’s motion during brief contact to calculate eye pressure.
Probe Supply
Model 16318 is supplied sterile for a single use. The probe works with the compatible Tono-Vera instrument, which provides alignment, calculation and display functions.
Who Else Makes It
Concentrated in Jiangsu (2), Beijing (1), Shanghai (1).
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Beijing Hongdee Corporation | Beijing | Beijing | Private-label distributor | 43 |
| Taizhou City K&W International Trade Co., Ltd. | Jiangyan | Jiangsu | Repacker / relabeller | 38 |
| Lianyungang Tiannuo Optical Instrument Co., Ltd. | Lianyungang | Jiangsu | Contract manufacturer | 31 |
| Shanghai Mediworks Precision Instruments Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 13 |
| Chongqing Sunkingdom Medical Instrument Co., Ltd. | Chongqing | Chongqing | Manufacturer | 11 |
Record
| Listed by | Reichert Inc., United States |
|---|---|
| FDA product code | HKY |
| Device type | Tonometer, Manual |
| Device class | Class 2 |
| Regulation | 21 CFR 886.1930 |
| Establishment | Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer |
| 510(k) | K233516 |
| Record published | 2025-08-12 |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date, manufacturing date, serial number |
Catalogue Numbers
| Catalogue number | Size | Per pack | Status |
|---|---|---|---|
| 16318 | 100 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Tonometer AT 900 | Haag-Streit AG | 7 |
| Ambler Surgical | Ambler Surgical, LLC | 7 |
| Ocu-Film® +” | Reichert Inc. | 5 |
| Bausch + Lomb | Bausch & Lomb Incorporated | 5 |
| AccuTip Cover | Accutome, Inc. | 4 |
| Mediworks | Shanghai Mediworks Precision Instruments Co., Ltd. | 4 |
| Applanation Tonometer | Chongqing Sunkingdom Medical Instrument Co., Ltd. | 3 |
| Icare ic200 | Icare Finland Oy | 3 |
| Marco | Takagi Seiko Co., Ltd. | 2 |
| S4 Optik | Costruzioni Strumenti Oftalmici C.S.O. SRL | 2 |
| iCare PATIENT2 | Icare Finland Oy | 2 |
| Tonometer AT 870 | Haag-Streit AG | 2 |
Showing 12 of 71. All products under Tonometer, Manual