Ufsk-Osys Treatment Chair
Treatment chair for positioning and support of the patient for outpatient microsurgical treatments in ophthalmology, ENT and dental surgery
Who Else Makes It
Concentrated in Jiangsu (4), Shanghai (1), Shaanxi (1). 2 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Wuxi Zontai Int’l Corporation Ltd. | Wuxi | Jiangsu | Contract manufacturer | 22 |
| Taiyuan North China Xinyuan Tech. Center (Co., Ltd.) | Taiyuan | Shaanxi | Contract manufacturer | 14 |
| Taizhou City K&W International Trade Co., Ltd. | Jiangyan | Jiangsu | Repacker / relabeller | 38 |
| Lianyungang Tiannuo Optical Instrument Co., Ltd. | Lianyungang | Jiangsu | Contract manufacturer | 31 |
| Shanghai Canton Optics Equipment Co., Ltd. | Shanghai | Shanghai | Manufacturer | 14 |
| Visuscience Meditech Co., Ltd. | Wuxi | Jiangsu | Specification developer | 9 |
Record
| Listed by | Ufsk-International Osys Gmbh, Germany |
|---|---|
| FDA product code | HME |
| Device type | Chair, Ophthalmic, Ac-Powered |
| Device class | Class 1 |
| Regulation | 21 CFR 886.1140 |
| Establishment | Manufacturer, Exporter |
| Premarket notification | Exempt |
| Record published | 2026-03-02 |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Label carries | manufacturing date, serial number |
| Distribution end date | 2027-01-01 |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 500 ECO | In distribution | |
| 500 XLS | In distribution | |
| 500 XLE | In distribution | |
| eyeForce | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| OC-2200 | Topcon Corp. | 105 |
| OC-2300 | Topcon Corp. | 52 |
| OC-2400 | Topcon Corp. | 21 |
| S4 Optik | Innova Medical Ophthalmics | 15 |
| Reliance | Haag-Streit USA, Inc. | 15 |
| Ufsk-Osys Surgeon’s chair | Ufsk-International Osys Gmbh | 8 |
| Marco | Takagi Seiko Co., Ltd. | 6 |
| Topcon | Antoni Carles SA | 4 |
| Lombart | Innova Medical Ophthalmics | 2 |
| Marco | Innova Medical Ophthalmics | 2 |
| Illuminix | Illuminix Industries LLC | 1 |
| Surgical Table | MDT SP. Z O.O. | 1 |
Showing 12 of 14. All products under Chair, Ophthalmic, Ac-Powered
Recalls
1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity |
|---|---|---|---|---|
| 2023-05-31 | Class II | Device Design | Service life of the electrical seat part drive of the treatment chair may be shortened unexpectedly after several years of use due to a potential wear-related reduction in the self-locking of the drive and may remain undetected. A worsened | 239 chairs US |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.