ClearCut®

ClearCut® S Safety Cresent Knife 2.3mm Angled Bevel Up

Registry build 21.09.26
12manufacturers in China registered for this device type
26catalogue numbers in this listing

Who Else Makes It

Concentrated in Jiangsu (9), Shanghai (1), Shandong (1).

Chinese manufacturers registered for FDA product code HNN
Manufacturer City Province Registered as Device types
Shanghai Medical Instruments (Group) Ltd. Corp. Shanghai Shanghai Contract manufacturer 235
Xinhua Surgical Instrument Co., Ltd. Zibo Shandong Manufacturer 222
Hospital & Homecare IMP. & EXP. Co., Ltd. Nanjing Jiangsu Contract manufacturer 179
66 Vision Tech Co., Ltd. Suzhou Jiangsu Private-label distributor 24
Asol Co., Ltd. Huaian Jiangsu Manufacturer 22
Huaian Tisurg Medical Instruments Co., Ltd. Huaian Jiangsu Contract manufacturer 22
Belle Healthcare Technology Co., Ltd. Suzhou Jiangsu Manufacturer 20
Sihong Ophsurin Co., Ltd. Suqian Jiangsu Manufacturer 17
Huaian Frimen Co., Ltd. Huaian Jiangsu Manufacturer 16
Huaian Wolfram Surgical Instruments Huaian Jiangsu Manufacturer 14
2nd Sight Medical Co., Ltd. Changzhou Jiangsu Manufacturer 1
Shaanxi Xingmao Industry Co., Ltd. Xi An Shaanxi Private-label distributor 1

Record

Regulatory record for ClearCut®
Listed by Alcon Laboratories, Inc., United States
FDA product code HNN
Device type Knife, Ophthalmic
Device class Class 1
Regulation 21 CFR 886.4350
Premarket notification Exempt
Record published 2020-08-18
Record revised 2026-03-02 (version 3)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date, manufacturing date
Packaging Pack of 6
Distribution end date 2023-12-31

Catalogue Numbers

Catalogue numbers for ClearCut®
Catalogue number Size Status
8065993047 In distribution
8065921540 In distribution
8065771541 In distribution
8065982665 In distribution
8065771501 In distribution
8065983265 In distribution
8065921541 In distribution
8065772745 In distribution
8065992647 In distribution
8065982865 In distribution
8065773001 In distribution
8065993245 In distribution
8065992745 In distribution
8065983065 In distribution
8065771540 In distribution
8065992747 In distribution
8065993045 In distribution
8065770002 In distribution
8065992645 Withdrawn
8065993048 Withdrawn
8065995240 Withdrawn
8065992848 Withdrawn
8065921542 Withdrawn
8065993540 Withdrawn
8065992648 Withdrawn
8065997048 Withdrawn

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Ambler Surgical Ambler Surgical, LLC 283
Mani Ophthalmic Knife Mani, Inc. 234
Unique Edge Unique Technologies, Inc. 186
Sharpoint Surgical Specialties México, S. de R.L. de C.V. 162
MSI Precision Specialty Instruments MED Saver, Inc. 154
Mastel Precision Surgical Instruments, Inc. Mastel Surgical Inc. 146
Anodyne Surgical Psi/Eye-Ko, Inc. 115
Ophthalmic Knife Ovation International 81
Ophthalmic Knife Katena Products, Inc. 72
Premier Edge® Microsurgical Knives Oasis Medical, Inc. 69
Micro Feather Disposable Ophthalmic Scalpel with plastic handle Feather Safety Razor Co., Ltd. 63
ExactEtch Diamatrix 63

Showing 12 of 434. All products under Knife, Ophthalmic

Recalls Naming This Product

13 recalls name this product by its own identifiers, the UDI on its label.

Recalls naming the identifiers of ClearCut®
Recalled by Identified by Initiated FDA class Root cause Reason Quantity
Alcon Research, LLC UDI-DI 2024-07-15 Class II Process control Alcon has detected an increase in complaint reports related to sharpness for specific ClearCut Dual Bevel Sideport and A-OK Comeal/Scleral V-Lance Ophthalmic knives. 20,034 units
Alcon Research, LLC UDI-DI 2024-07-15 Class II Process control Alcon has detected an increase in complaint reports related to sharpness for specific ClearCut Dual Bevel Sideport and A-OK Comeal/Scleral V-Lance Ophthalmic knives. 5,039 units
Alcon Research, LLC UDI-DI 2024-07-15 Class II Process control Alcon has detected an increase in complaint reports related to sharpness for specific ClearCut Dual Bevel Sideport and A-OK Comeal/Scleral V-Lance Ophthalmic knives. 469,173 units
Alcon Research, LLC UDI-DI 2024-07-15 Class II Process control Alcon has detected an increase in complaint reports related to sharpness for specific ClearCut Dual Bevel Sideport and A-OK Comeal/Scleral V-Lance Ophthalmic knives. 2,520 units
Alcon Research, LLC UDI-DI 2024-07-15 Class II Process control Alcon has detected an increase in complaint reports related to sharpness for specific ClearCut Dual Bevel Sideport and A-OK Comeal/Scleral V-Lance Ophthalmic knives. 7,598 units
Alcon Research, LLC UDI-DI 2024-07-15 Class II Process control Alcon has detected an increase in complaint reports related to sharpness for specific ClearCut Dual Bevel Sideport and A-OK Comeal/Scleral V-Lance Ophthalmic knives. 5,487 units
Alcon Research, LLC UDI-DI 2024-07-15 Class II Process control Alcon has detected an increase in complaint reports related to sharpness for specific ClearCut Dual Bevel Sideport and A-OK Comeal/Scleral V-Lance Ophthalmic knives. 145,248 units
Alcon Research, LLC UDI-DI 2024-07-15 Class II Process control Alcon has detected an increase in complaint reports related to sharpness for specific ClearCut Dual Bevel Sideport and A-OK Comeal/Scleral V-Lance Ophthalmic knives. 53,123 units
Alcon Research, LLC UDI-DI 2024-07-15 Class II Process control Alcon has detected an increase in complaint reports related to sharpness for specific ClearCut Dual Bevel Sideport and A-OK Comeal/Scleral V-Lance Ophthalmic knives. 11,676 units
Alcon Research, LLC UDI-DI 2024-07-15 Class II Process control Alcon has detected an increase in complaint reports related to sharpness for specific ClearCut Dual Bevel Sideport and A-OK Comeal/Scleral V-Lance Ophthalmic knives. 15,222 units
Alcon Research, LLC UDI-DI 2024-04-22 Class II Process control Alcon has detected an increase in complaint reports related to sharpness for specific ClearCut Dual Bevel Sideport and A-OK Corneal/Scleral V-Lance Ophthalmic knives. 427,764 units
Alcon Research, LLC UDI-DI 2024-04-22 Class II Process control Alcon has detected an increase in complaint reports related to sharpness for specific ClearCut Dual Bevel Sideport and A-OK Corneal/Scleral V-Lance Ophthalmic knives. 19,867 units
Alcon Research, LLC UDI-DI 2024-04-22 Class II Process control Alcon has detected an increase in complaint reports related to sharpness for specific ClearCut Dual Bevel Sideport and A-OK Corneal/Scleral V-Lance Ophthalmic knives. 4,930 units

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer