Malosa Medical
Fine Notched Forceps Short (Hoskins)
12manufacturers in China registered for this device type
21catalogue numbers in this listing
1recall
Who Else Makes It
Concentrated in Jiangsu (9), Shanghai (1), Shandong (1). One is registered as a contract manufacturer, able to build to a specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Malosa Medical Instruments (Changshu) Limited | Changshu | Jiangsu | Contract manufacturer | 24 |
| Shanghai Medical Instruments (Group) Ltd. Corp. | Shanghai | Shanghai | Contract manufacturer | 235 |
| Xinhua Surgical Instrument Co., Ltd. | Zibo | Shandong | Manufacturer | 222 |
| Hubei Lanbin Medical Group Co., Ltd. | Xiaogan | Hubei | Contract manufacturer | 33 |
| 66 Vision Tech Co., Ltd. | Suzhou | Jiangsu | Private-label distributor | 24 |
| Asol Co., Ltd. | Huaian | Jiangsu | Manufacturer | 22 |
| Huaian Tisurg Medical Instruments Co., Ltd. | Huaian | Jiangsu | Contract manufacturer | 22 |
| Belle Healthcare Technology Co., Ltd. | Suzhou | Jiangsu | Manufacturer | 20 |
| Sihong Ophsurin Co., Ltd. | Suqian | Jiangsu | Manufacturer | 17 |
| Huaian Frimen Co., Ltd. | Huaian | Jiangsu | Manufacturer | 16 |
| Huaian Wolfram Surgical Instruments | Huaian | Jiangsu | Manufacturer | 14 |
| Visuscience Meditech Co., Ltd. | Wuxi | Jiangsu | Specification developer | 9 |
Record
| Listed by | Beaver-Visitec International, Ltd, United Kingdom |
|---|---|
| FDA product code | HNR |
| Device type | Forceps, Ophthalmic |
| Device class | Class 1 |
| Regulation | 21 CFR 886.4350 |
| Establishment | Contract manufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer |
| Premarket notification | Exempt |
| Record published | 2022-02-15 |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Latex | Contains natural rubber latex |
| Label carries | lot or batch number, expiry date, manufacturing date |
Catalogue Numbers
| Catalogue number | Size | Per pack | Status |
|---|---|---|---|
| MMSU0241S | 20 | In distribution | |
| MMSU1419S | 20 | In distribution | |
| MMSU1568S | 20 | In distribution | |
| MMSU1209S | 20 | In distribution | |
| MMSU0283S | 20 | In distribution | |
| MMSU1114S | 20 | In distribution | |
| MMSU0085S | 20 | In distribution | |
| MMSU0286S | 20 | In distribution | |
| MMSU1115S | 20 | In distribution | |
| MMSU1125S | 20 | In distribution | |
| MMSU0276S | 20 | In distribution | |
| MMSU1129S | 20 | In distribution | |
| MMSU1124S | 20 | In distribution | |
| MMSU1571S | 20 | In distribution | |
| MMSU1127S | 20 | In distribution | |
| MMSU1219S | 20 | In distribution | |
| MMSU1284S | 20 | In distribution | |
| MMSU1210S | 20 | In distribution | |
| MMSU1583S | 20 | In distribution | |
| MMSU0247S | 20 | In distribution | |
| MMSU0277S | 20 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Ambler Surgical | Ambler Surgical, LLC | 812 |
| MSI Precision Specialty Instruments | MED Saver, Inc. | 542 |
| Walcott Rx Products | Walcott Rx Product Inc | 365 |
| Sklar | Sklar Corporation | 346 |
| Millennium | Avalign Technologies, Inc. | 329 |
| MR Phaco | Crestpoint Management Ltd. | 322 |
| Bausch + Lomb | Bausch & Lomb Incorporated | 313 |
| Epsilon USA | Epsilon EYE Care PVT., Ltd. | 283 |
| Stephens Instruments | Krishna Imports Inc | 275 |
| Wexler Surgical, Inc. | Wexler Surgical, Inc. | 256 |
| Rumex | Rumex International Co. | 248 |
| Assi | Accurate Surgical & Scientific Instruments Corp. | 195 |
Showing 12 of 1,959. All products under Forceps, Ophthalmic
Recalls
The FDA has not published a severity grade for these. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2008-07-07 | Not classified | Manufacturing material removal | Metal particulates present. | 260 units | 2012-02-29 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.