Bausch + Lomb
27 ga. Bi-Blade Vitreous Cutter Posterior Wide-Field Stellaris Elite Pack
Who Else Makes It
Concentrated in Guangdong (2), Shanghai (1), Jiangsu (1). 3 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Sanmina | Kunshan | Jiangsu | Contract manufacturer | 15 |
| Providence Enterprise Limited | Shenzhen | Guangdong | Contract manufacturer | 9 |
| ABA Medical Technology Co Ltd | Guang Dong | Guangdong | Contract manufacturer | 6 |
| Sterigenics Shanghai ETO Ltd. | Shanghai | Shanghai | Contract manufacturer | 65 |
Record
| Listed by | Bausch & Lomb Incorporated, United States |
|---|---|
| FDA product code | HQC |
| Device type | Unit, Phacofragmentation |
| Device class | Class 2 |
| Regulation | 21 CFR 886.4670 |
| Establishment | Remanufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter |
| Premarket notification | Exempt |
| Record published | 2016-09-24 |
| Record revised | 2025-10-10 (version 13) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Sterilisation | Moist Heat or Steam Sterilization |
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Supplied as a kit | Yes |
| Label carries | lot or batch number, expiry date, serial number |
| UDI direct marking | Exempt |
Catalogue Numbers
| Catalogue number | Size | Per pack | Status |
|---|---|---|---|
| DP8300 | In distribution | ||
| BL5121 | 6 | In distribution | |
| SE5620AV | 6 | In distribution | |
| BL5277 | 6 | In distribution | |
| SE14565E | In distribution | ||
| DP8130 | 6 | In distribution | |
| BLV0000000 | 6 | In distribution | |
| SE5625BB+ | 6 | In distribution | |
| BL5113 | 6 | In distribution | |
| BLS226TT30 | 6 | In distribution | |
| DP8330A | In distribution | ||
| SE5627BB+ | 6 | In distribution | |
| DP8215 | In distribution | ||
| DP8315 | In distribution | ||
| DP8930S | 6 | In distribution | |
| ET4750 AP23 | In distribution | ||
| DP8245S | 6 | In distribution | |
| SE5425MV | 6 | In distribution | |
| SE15565 | In distribution | ||
| SE5427WVB | 6 | In distribution | |
| BL3270 | In distribution | ||
| MVS 1052 | In distribution | ||
| DP8430S | 6 | In distribution | |
| BL5277 | In distribution | ||
| BLV322MM30 | 6 | In distribution | |
| DP5511 | 6 | In distribution | |
| MVS1083 | In distribution | ||
| SE5423MVB | 6 | In distribution | |
| BL3160 | In distribution | ||
| SE5527WVB | 6 | In distribution | |
| DP5200A | 6 | In distribution | |
| DP8730S | 6 | In distribution | |
| BL3318S | 6 | In distribution | |
| SE5525MVB | 6 | In distribution | |
| DP4310 | 6 | In distribution | |
| SE15565E | In distribution | ||
| BLV3220000 | 6 | In distribution | |
| BL3420S | 6 | In distribution | |
| BL5110 | 6 | In distribution | |
| DP8730 | In distribution | ||
| BL3124 | In distribution | ||
| DP5100 | 6 | In distribution | |
| BL5275 | 6 | In distribution | |
| BL3162 | In distribution | ||
| BLV4180000 | 6 | In distribution | |
| BL3170 | In distribution | ||
| BL3164 | In distribution | ||
| BLV128MP30 | 6 | In distribution | |
| BL5114A | 6 | In distribution | |
| DP8330S | 6 | In distribution | |
| BL5120 | 6 | In distribution | |
| BL3420AS | 6 | In distribution | |
| DP4305 | 12 | In distribution | |
| DP8030S | 6 | In distribution | |
| BL3163 | In distribution | ||
| BL5113A | 6 | In distribution | |
| SE14565 | In distribution | ||
| SE5625 | 6 | In distribution | |
| DP8330 | In distribution | ||
| DP8145S | 6 | In distribution | |
| BL3234 | In distribution | ||
| CX9503 | 10 | In distribution | |
| SE5623AVBB+ | 6 | In distribution | |
| D4600A | 6 | In distribution | |
| BLS0000000 | 6 | In distribution | |
| SE5623AV | 6 | In distribution | |
| DP8245 | In distribution | ||
| BL5111 | 6 | In distribution | |
| BL5625S | 6 | In distribution | |
| BL5123 | 6 | In distribution | |
| BL5123A | 6 | In distribution | |
| DP8830AS | 6 | In distribution | |
| DP8230 | In distribution | ||
| SE5627B | 6 | In distribution | |
| BL3166 | In distribution | ||
| SE5525MV | 6 | In distribution | |
| DP8430AS | 6 | In distribution | |
| BL5114 | 6 | In distribution | |
| BL3124S | 12 | In distribution | |
| BLP324MX30 | 6 | In distribution | |
| ET4753 A23 | In distribution | ||
| BL3118 | 6 | In distribution | |
| DP8345 | In distribution | ||
| CX4320 | 6 | In distribution | |
| ET4750 A23 | In distribution | ||
| DP5531 | 6 | In distribution | |
| SE5523MV | 6 | In distribution | |
| DP8930AS | 6 | In distribution | |
| BL3318AS | 6 | In distribution | |
| SE5427MVB | 6 | In distribution | |
| BL3165 | In distribution | ||
| MVS 1063 | In distribution | ||
| BL5112 | 6 | In distribution | |
| BLP226MX30 | 6 | In distribution | |
| BL5280 | 6 | In distribution | |
| SE5520M | 6 | In distribution | |
| MVS 1063C | In distribution | ||
| DP8130S | 6 | In distribution | |
| BLV2260000 | 6 | In distribution | |
| MVS 1061L | In distribution | ||
| BL3161 | In distribution | ||
| SE5425MVB | 6 | In distribution | |
| BL5427MVXB | 6 | In distribution | |
| DP5501 | 12 | In distribution | |
| DP8830S | 6 | In distribution | |
| MVS 1063S | In distribution | ||
| DP8230S | 6 | In distribution | |
| SE5623BB+ | 6 | In distribution | |
| BLV126MF30 | 6 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Alcon | Alcon Laboratories, Inc. | 95 |
| Oertli® | Oertli Instrumente AG | 66 |
| Laminar | Johnson & Johnson Surgical Vision, Inc. | 40 |
| Engauge | Alcon Laboratories, Inc. | 18 |
| Unity | Alcon Laboratories, Inc. | 18 |
| Constellation | Alcon Laboratories, Inc. | 16 |
| MST/Packard A1.7mm Phaco Tip Bent Dewey 30° | Microsurgical Technology, Inc. | 11 |
| Whitestar Signature | Johnson & Johnson Surgical Vision, Inc. | 10 |
| Alcon, Infiniti, MicroSmooth, ABS | Alcon Laboratories, Inc. | 10 |
| Compact Intuitiv | Johnson & Johnson Surgical Vision, Inc. | 9 |
| Alcon, Infiniti, Intrepid | Alcon Laboratories, Inc. | 9 |
| MST.7mm A1 Bent Phaco Tip 45° | Microsurgical Technology, Inc. | 8 |
Showing 12 of 619. All products under Unit, Phacofragmentation
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K170052 | 2017-04-19 |
| K162342 | 2017-03-24 |
| K133486 | 2014-03-12 |
| K133242 | 2014-02-14 |
| K101325 | 2010-08-17 |
| K082473 | 2009-01-05 |
| K082132 | 2008-08-28 |
| K073023 | 2008-03-12 |
| K063331 | 2006-12-19 |
| K041998 | 2004-08-16 |
| K033653 | 2003-12-17 |
Recalls Naming This Product
3 recalls name this product by its own identifiers, the UDI on its label.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Bausch & Lomb Incorporated | UDI-DI | 2018-08-08 | Class II | Nonconforming Material/Component | The back cap separates from the body of the vitrectomy cutter. | 67 cases | 2019-08-28 |
| Bausch & Lomb Incorporated | UDI-DI | 2018-08-08 | Class II | Nonconforming Material/Component | The back cap separates from the body of the vitrectomy cutter. | 39.33 cases | 2019-08-28 |
| Bausch & Lomb Incorporated | UDI-DI | 2018-08-08 | Class II | Nonconforming Material/Component | The back cap separates from the body of the vitrectomy cutter. | 66 cases | 2019-08-28 |
Recalls
1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2012-08-31 | Class II | Process control | Posterior fluidics modules installed in the system may need to be recalibrated. | 124 units | 2013-07-11 |
| 2011-07-27 | Not classified | Nonconforming Material/Component | The aspiration channel on the affected vacuum cassettes may be blocked due to a molding malfunction | 229/6-unit cases | 2013-06-21 |
| 2011-07-27 | Not classified | Nonconforming Material/Component | The aspiration channel on the affected vacuum cassettes may be blocked due to a molding malfunction | 6/6-unit cases | 2013-06-21 |
| 2011-07-27 | Not classified | Nonconforming Material/Component | The aspiration channel on the affected vacuum cassettes may be blocked due to a molding malfunction | 9/6-unit cases | 2013-06-21 |
| 2011-07-27 | Not classified | Nonconforming Material/Component | The aspiration channel on the affected vacuum cassettes may be blocked due to a molding malfunction | 2/6-unit cases | 2013-06-21 |
| 2010-01-08 | Not classified | Component design/selection | Users may incorrectly assemble the plastic needle wrench to the phacoemulsification needle resulting in the generation of plastic particulate | 280/6-pouch boxes | 2012-04-02 |
| 2010-01-08 | Not classified | Component design/selection | Users may incorrectly assemble the plastic needle wrench to the phacoemulsification needle resulting in the generation of plastic particulate | 7,256/12-pack boxes | 2012-04-02 |
| 2010-01-08 | Not classified | Component design/selection | Users may incorrectly assemble the plastic needle wrench to the phacoemulsification needle resulting in the generation of plastic particulate | 8,964/6-pack boxes | 2012-04-02 |
| 2010-01-08 | Not classified | Component design/selection | Users may incorrectly assemble the plastic needle wrench to the phacoemulsification needle resulting in the generation of plastic particulate | 308/6-pouch boxes | 2012-04-02 |
| 2010-01-08 | Not classified | Component design/selection | Users may incorrectly assemble the plastic needle wrench to the phacoemulsification needle resulting in the generation of plastic particulate | 1,958/6-pouch boxes | 2012-04-02 |
| 2010-01-08 | Not classified | Component design/selection | Users may incorrectly assemble the plastic needle wrench to the phacoemulsification needle resulting in the generation of plastic particulate | 6,111/6-pouch boxes | 2012-04-02 |
| 2010-01-08 | Not classified | Component design/selection | Users may incorrectly assemble the plastic needle wrench to the phacoemulsification needle resulting in the generation of plastic particulate | 286/6-pouch boxes | 2012-04-02 |
| 2010-01-08 | Not classified | Component design/selection | Users may incorrectly assemble the plastic needle wrench to the phacoemulsification needle resulting in the generation of plastic particulate | 233/6-pouch boxes | 2012-04-02 |
| 2010-01-08 | Not classified | Component design/selection | Users may incorrectly assemble the plastic needle wrench to the phacoemulsification needle resulting in the generation of plastic particulate | 783/6-pouch boxes | 2012-04-02 |
| 2010-01-08 | Not classified | Component design/selection | Users may incorrectly assemble the plastic needle wrench to the phacoemulsification needle resulting in the generation of plastic particulate | 2,282/6-pouch boxes | 2012-04-02 |
| 2010-01-08 | Not classified | Component design/selection | Users may incorrectly assemble the plastic needle wrench to the phacoemulsification needle resulting in the generation of plastic particulate | 1,265/6-pack boxes | 2012-04-02 |
| 2003-08-25 | Not classified | Other | The firm’s DP8200 Microflow Needle Packs were labeled with the firm’s DP8115 Phaco Needle Packs and visa versa. | 44 boxes | 2003-12-15 |
| 2003-08-25 | Not classified | Other | The firm’s DP8200 Microflow Needle Packs were labeled with the firm’s DP8115 Phaco Needle Packs and visa versa. | 22 boxes | 2003-12-15 |