Monarch® III

The Monarch® "D" Cartridge is a single-use polypropylene cartridge for posterior chamber IOL delivery

Registry build 21.09.26
1manufacturer
2catalogue numbers in this listing
3510(k) clearances naming this product code

Who Else Makes It

Registered in Shanghai.

Chinese manufacturers registered for FDA product code KYB
Manufacturer City Province Registered as Device types
Shanghai Medical Instruments (Group) Ltd. Corp. Shanghai Shanghai Contract manufacturer 235

Record

Regulatory record for Monarch® III
Listed by Alcon Laboratories, Inc., United States
FDA product code KYB
Device type Lens, Guide, Intraocular
Device class Class 1
Regulation 21 CFR 886.4300
Premarket notification Exempt
Record published 2020-08-19
Record revised 2022-12-08 (version 2)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Sterilisation Moist Heat or Steam Sterilization
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date, manufacturing date, serial number
Packaging Pack of 10

Catalogue Numbers

Catalogue numbers for Monarch® III
Catalogue number Size Status
8065977773 In distribution
8065977763 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Duckworth & Kent Duckworth AND Kent Limited 5
Unfolder Emerald Johnson & Johnson Surgical Vision, Inc. 3
Monarch® II Alcon Laboratories, Inc. 2
MSI Precision Specialty Instruments MED Saver, Inc. 2
Unfolder Silver Johnson & Johnson Surgical Vision, Inc. 2
IOL Manipulator – Sinskey Hurricane Medical 2
Lens Exchange Sytem Visioncare Ophthalmic Technologies Ltd. 2
Viscoject 1.8 Injector Set Medicel AG 1
Bausch + Lomb Bausch & Lomb Incorporated 1
Nucleus Chopper – P. Koch Hurricane Medical 1
Surgical Glide Hurricane Medical 1
Unfolder Platinum 1 Series Johnson & Johnson Surgical Vision, Inc. 1

Showing 12 of 18. All products under Lens, Guide, Intraocular

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K981571 1998-07-09
K970033 1997-04-23
K965185 1997-03-31

Recalls Naming This Product

1 recall names this product by its own identifier, the UDI on its label.

Recalls naming the identifiers of Monarch® III
Recalled by Identified by Initiated FDA class Root cause Reason Quantity
Alcon Research, LLC UDI-DI 2024-11-13 Class II Process design Increase in complaints associated with a molding defect within the inner lumen of delivery cartridges which could result in a scratch on the intraocular lens (IOL) upon delivery. 41718 units

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker