Ablaor / Eflex

Vulcan Eflex Ablator Ablator Probe With Integrated Cable

Registry build 21.09.26
21manufacturers in China registered for this device type
1catalogue number
19510(k) clearances naming this product code
8recalls on this code

Who Else Makes It

Concentrated in Shanghai (7), Jiangsu (6), Guangdong (5). 6 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code HRX
Manufacturer City Province Registered as Device types
Modern Medical Equipment Manufacturing Ltd. Heng Li, Dongguan Guangdong Contract manufacturer 26
Dongguan BAO Kang Dian ZI KE JI Limited Dongguan Guangdong Contract manufacturer 24
Sanmina Kunshan Jiangsu Contract manufacturer 15
Peter’s Technology (Suzhou) Co., Ltd. Suzhou Jiangsu Contract manufacturer 9
Jiangsu Shenli Medical Production Co., Ltd. Changzhou Jiangsu Contract manufacturer 6
PAN-International Precision Electronic Co., Ltd. Dongguan Guangdong Contract manufacturer 4
Zimmer (Shanghai) Medical International Trading Co., Ltd. Shanghai Shanghai Exporter 106
Shanghai JPY ION-Tech Co., Ltd. Shanghai Shanghai Contract manufacturer 70
Medtronic (Changzhou) Medical Devices Technology Co., Ltd. Changzhou Jiangsu Manufacturer 53
Hangzhou Fushan Medical Appliance Co., Ltd. Hangzhou Zhejiang Contract manufacturer 44
Arthrex (Shanghai) Co., Ltd. Shanghai Shanghai Exporter 38
Goals Sterilization Co., Ltd. Jiaxing Zhejiang Contract manufacturer 26

Showing 12 of 21. All 21 manufacturers in China registered for Arthroscope

Record

Regulatory record for Ablaor / Eflex
Listed by Smith & Nephew, Inc., United States
FDA product code HRX
Device type Arthroscope
Device class Class 2
Regulation 21 CFR 888.1100
Establishment Contract manufacturer, Remanufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter
510(k) K003893
Record published 2015-08-29
Record revised 2024-10-28 (version 5)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date

Catalogue Numbers

Catalogue numbers for Ablaor / Eflex
Catalogue number Size Status
72200683 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Surgical Direct Surgical Direct, Inc. 299
Arthroscope Karl Storz GmbH & Co. KG 278
Conmed/Linvatec Provision 265
Arthroscope Smith & Nephew, Inc. 255
Medline Medline Industries, Inc. 205
Arthroscope Sterilmed, Inc. 184
Sustainable Technologies Provision 150
Medline Renewal Medline Industries, Inc. 123
Stryker Provision 113
Arthrex® Arthrex, Inc. 109
Arthrex Provision 109
Eberle Eberle GmbH & Co. KG 92

Showing 12 of 567. All products under Arthroscope

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K201349 2020-07-20
K192155 2019-09-04
K171794 2017-06-27
K072675 2007-10-15
K062849 2007-01-19
K051326 2005-06-15
K043395 2005-01-12
K031605 2003-06-18
K030196 2003-02-20
K003572 2001-02-15
K001226 2000-06-26
K981156 1998-05-20
K970511 1997-08-12
K971676 1997-06-27
K971253 1997-06-13
K941036 1994-09-28
K940222 1994-06-29
K922519 1994-03-29
K901617 1990-05-29

Recalls

1 of these is Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2020-06-24 Class II Process design The T-Fix sterile package contains only one sleeve instead of two, The device will not perform as intended for the second bone tunnel due to the absence of thesleeve 137 Lot 2042492; 130 Lot 2049408
2009-05-27 Not classified Package design/selection The sterility of the device cannot be assured 67,697 units 2012-05-08
2009-05-27 Not classified Package design/selection The sterility of the device cannot be assured 67,697 units 2012-05-08
2008-08-07 Not classified Packaging process control Integrity of the remote control bag may not be sufficient to prevent tearing or opening of the bag during use. 3,504 units 2012-05-08
2008-08-07 Not classified Packaging process control Integrity of the remote control bag may not be sufficient to prevent tearing or opening of the bag during use. 4,044 units 2012-05-08
2008-08-07 Not classified Packaging process control Integrity of the remote control bag may not be sufficient to prevent tearing or opening of the bag during use. 11,469 units 2012-05-08
2008-08-07 Not classified Packaging process control Integrity of the remote control bag may not be sufficient to prevent tearing or opening of the bag during use. 3,222 units 2012-05-08
2002-11-08 Not classified Process control Potential for non sterility as package tray does not contain aeration holes for ETO processing. 77 units 2005-04-20

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer