Evos

Evos 3.5MM Partial Articular Posteromedial Proximal Tibia I-Plate 8 Hole Left 111MM

Registry build 21.09.26
22manufacturers in China registered for this device type
2,235catalogue numbers in this listing
37510(k) clearances naming this product code
15recalls on this code

Who Else Makes It

Concentrated in Jiangsu (10), Shanghai (4), Zhejiang (3). 12 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code HRS
Manufacturer City Province Registered as Device types
Apex (Guangzhou) Tools & Orthopedics Company Guangzhou Guangdong Contract manufacturer 62
Changzhou Biomet Medical Devices Co., Ltd. Changzhou Jiangsu Contract manufacturer 54
Paragon Medical Device (Changzhou) Co., Ltd. Changzhou Jiangsu Contract manufacturer 53
Canwell Medical Co., Ltd. Jinhua Zhejiang Contract manufacturer 42
Suzhou Elite Precision Machinery Co., Ltd. Kunshan Jiangsu Contract manufacturer 35
LX Precision Shanghai Co Ltd Shanghai Shanghai Contract manufacturer 19
Stryker (Suzhou) Medical Technology Co., Ltd. Suzhou Jiangsu Contract manufacturer 19
Suzhou Kangli Orthopaedics Instrument Co., Ltd. Zhangjiagang Jiangsu Contract manufacturer 11
Kingj Medical Co., Ltd. Zhangjiagang Jiangsu Contract manufacturer 7
Hangzhou Sino-MIM Technology Co., Ltd. Hangzhou Zhejiang Contract manufacturer 6
Suzhou AND Science & Technology Development Corp. Zhangjiagang Jiangsu Contract manufacturer 5
Beijing AK Medical Co., Ltd. Changping District Beijing Contract manufacturer 3

Showing 12 of 22. All 22 manufacturers in China registered for Plate, Fixation, Bone

Record

Regulatory record for Evos
Listed by Smith & Nephew, Inc., United States
FDA product code HRS
Device type Plate, Fixation, Bone
Device class Class 2
Regulation 21 CFR 888.3030
Establishment Contract manufacturer, Remanufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter
510(k) K162078
Record published 2017-02-22
Record revised 2025-11-20 (version 12)

Specifications

Specifications
MRI safety MR Conditional
Sterilisation Moist Heat or Steam Sterilization
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Supplied as a kit Yes
Label carries lot or batch number, expiry date, manufacturing date
Storage Special storage condition: : –
Sizes Length 6 to 150 mm; outer diameter 2.4 mm
Distribution end date 2022-03-17
UDI direct marking Exempt

Catalogue Numbers

Catalogue numbers for Evos
Catalogue number Size Status
72424775 In distribution
72424734 In distribution
72575208N In distribution
72442778N In distribution
72413565 In distribution
72465909N In distribution
72466707N In distribution
72467209 In distribution
72442060 In distribution
73391922N In distribution
72434726N In distribution
72467104 In distribution
72442124N In distribution
71175680N In distribution
72572106N In distribution
72465016 In distribution
72586114 In distribution
72454006 In distribution
72466117 In distribution
72466514N In distribution
72583201N In distribution
71935843 In distribution
72467212N In distribution
72403526N In distribution
75413510N In distribution
72402416 In distribution
72464509N In distribution
72402480N In distribution
72402712 Length 12 mm In distribution
72402018 Length 18 mm In distribution
72465407N In distribution
71177713 In distribution
72411810 In distribution
72402013N In distribution
72413526N In distribution
72467809N In distribution
72412414 Length 14 mm In distribution
72442468 In distribution
72454103N In distribution
72455405N In distribution
72414710 In distribution
71177022 In distribution
72442462N In distribution
72455407N In distribution
72411820N In distribution
72465105N In distribution
72574206 In distribution
72454409 In distribution
72402711N In distribution
72402424 Length 24 mm In distribution
72424032N In distribution
71177710 In distribution
71158110 In distribution
72463915 In distribution
72468110N In distribution
72561008 In distribution
72412765 In distribution
72468104N In distribution
72572112 In distribution
72574104N In distribution
72468207N In distribution
72402732 Length 32 mm In distribution
71158407N In distribution
72412742N In distribution
72454103 In distribution
72402407N In distribution
72412736 In distribution
70273104 4 HOLE: 4 HOLE In distribution
72469818 In distribution
72402746 Length 46 mm In distribution
72464506N In distribution
72412709 In distribution
72574117N In distribution
72464913 In distribution
72402011 Length 11 mm In distribution
72423040 In distribution
72585115N In distribution
72463708N In distribution
72466903N In distribution
72468103 In distribution
72424712N In distribution
72402030N In distribution
72453708N In distribution
72571103 In distribution
72412432 In distribution
72465311N In distribution
72402444 In distribution
72412480N In distribution
72423032 In distribution
72412007N In distribution
72423026N In distribution
72453204N In distribution
72442470 In distribution
72442470N In distribution
72402718 Diameter: 2.7 mm In distribution
72412417N In distribution
72562012 In distribution
72468103N In distribution
72467906N In distribution
72586220 In distribution
72412722 In distribution
72572104 In distribution
71158604N In distribution
72463307 In distribution
72402028 Length 28 mm In distribution
72464018N In distribution
71177742 In distribution
71158107 In distribution
72411823N In distribution
71177041 In distribution
72467106 In distribution
72434048 In distribution
72402017N In distribution
72464805 In distribution
72424750N In distribution
72466307 In distribution
72402755N In distribution
72412408N In distribution
72574211 In distribution
72467307 In distribution
72423014 In distribution
72465405N In distribution
72465407 In distribution
72463710 In distribution
72562010 In distribution
72581012N In distribution
73391919 In distribution
72403540N In distribution
72463413N In distribution
72412418 In distribution
72402014N In distribution
72586209 In distribution
72412775N In distribution
72424724N In distribution
72586206 In distribution
72412010 In distribution
72412740 In distribution
72412422N In distribution
72403540 Diameter: 3.5 mm In distribution
72469116N In distribution
72423060 In distribution
72454506N In distribution
72442452N In distribution
72586103 In distribution
72424748N In distribution
72424042N In distribution
72423022 In distribution
72414744 In distribution
72402765N In distribution
E0016767-1 In distribution
72402765 Diameter: 2.7 mm In distribution
72454009 In distribution
72402032N In distribution
72464320N In distribution
71175622 In distribution
72465203N In distribution
72434055 In distribution
70272306 Diameter: 2.7-3.5 Millimeter In distribution
72424014 In distribution
72466213 In distribution
72423065 In distribution
72574217N In distribution
72571209 In distribution
70275109 9 HOLE: 9 HOLE In distribution
72574215N In distribution
72442454 In distribution
72453106 In distribution
72424016 In distribution
72440912N In distribution
75403512N In distribution
72413516N In distribution
72402736N In distribution
72412711N In distribution
72423050N In distribution
72468913N In distribution
72586101N In distribution
72402016 In distribution
72412736N In distribution
72464009N In distribution
72469212N In distribution
72468203N In distribution
75413514 In distribution
72414740 In distribution
72575117 In distribution
72571105 In distribution
72440612 In distribution
72402019 Diameter: 2 mm In distribution
72464320 In distribution
72442774 In distribution
72464515 In distribution
72442462 In distribution
72402023N In distribution
72465209N In distribution
72442452 In distribution
72402712N In distribution
72469509 In distribution
72412413 In distribution
72412411N In distribution
72402026N In distribution
72453508N In distribution
72411828 In distribution
70276301 5 HOLE: 5 HOLE In distribution
72413512N In distribution
72571213 In distribution
72442220N In distribution
73391916 In distribution
71175631 In distribution
72465216N In distribution
72466614N In distribution
71175644 In distribution
72402038 Length 38 mm In distribution
72572218N In distribution
72412723N In distribution
72465503 In distribution
72469508 In distribution
71175624 In distribution
72412015N In distribution
72571115 In distribution
72465113 In distribution
72467707 In distribution
72402714 Diameter: 2.7 mm In distribution
73391919N In distribution
72412415N In distribution
72402012 Length 12 mm In distribution
72585218 In distribution
72442074N In distribution
72434075 In distribution
72413590N In distribution
72464911 In distribution
72434044N In distribution
72423080 In distribution
72463122N In distribution
72402438N In distribution
72412019 In distribution
72412730N In distribution
70271614 14 HOLE: 14 HOLE In distribution
72423042N In distribution
72463921N In distribution
76112490 In distribution
72464512 In distribution
72424036N In distribution
72465309 In distribution
72454603 In distribution
72585219N In distribution
72466503N In distribution
72464420 In distribution
72402421N Length 21 mm In distribution
72434065N In distribution
72440218 In distribution
72572204N In distribution

Showing 250 of 300 catalogue numbers.

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Pectus System Biomet Microfixation 4,662
Arthrex® Arthrex, Inc. 3,031
Peri-Loc Smith & Nephew, Inc. 2,196
OsteoMed Osteomed 1,961
VariAx Stryker GmbH 1,934
Aptus Medartis Inc. 1,688
TC-100 Smith & Nephew, Inc. 1,639
Plate, Fixation, Bone Synthes Gmbh 1,613
Anthem Globus Medical, Inc. 1,551
Acumed Acumed LLC 1,360
Signex Osteonic Co., Ltd. 1,310
LCP Synthes Gmbh 1,295

Showing 12 of 3,530. All products under Plate, Fixation, Bone

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K241666 2025-02-19
K240487 2024-09-03
K223762 2023-05-30
K213123 2022-10-18
K210837 2021-06-29
K203405 2021-01-27
K201918 2020-11-16
K201527 2020-07-22
K190253 2019-03-11
K181533 2018-08-09
K173293 2018-01-08
K172262 2017-08-23
K170457 2017-06-14
K170887 2017-04-24
K163086 2016-12-21
K162078 2016-11-18
K161665 2016-11-15
K152976 2015-11-12
K143050 2014-12-18
K140814 2014-05-07
K132886 2014-02-04
K132296 2014-01-07
K123055 2013-01-25
K120667 2012-04-04
K112406 2011-11-14
K110670 2011-07-12
K092015 2009-07-30
K090675 2009-06-04
K083032 2009-01-07
K081106 2008-06-18
K072818 2007-11-19
K071563 2007-08-08
K062216 2006-09-15
K061352 2006-06-08
K051735 2005-07-19
K033669 2003-12-10
K993106 1999-12-09

Recalls Naming This Product

9 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of Evos
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Smith & Nephew, Inc. 510(k) number 2021-11-01 Class II Under Investigation by firm Testing vendor notified Smith & Nephew that previous MRI scanning conditions provided in Exponents reports were erroneous. Erroneous data from the reports was incorporated in the released IFU
81110294 EVOS Large Fragment Plating System.
38 units 2026-06-15
Smith & Nephew, Inc. 510(k) number 2021-11-01 Class II Under Investigation by firm Testing vendor notified Smith & Nephew that previous MRI scanning conditions provided in Exponents reports were erroneous. Erroneous data from the reports was incorporated in the released IFU
81110294 EVOS Large Fragment Plating System.
35 units 2026-06-15
Smith & Nephew, Inc. 510(k) number 2021-11-01 Class II Under Investigation by firm Testing vendor notified Smith & Nephew that previous MRI scanning conditions provided in Exponents reports were erroneous. Erroneous data from the reports was incorporated in the released IFU
81110294 EVOS Large Fragment Plating System.
35 units 2026-06-15
Smith & Nephew, Inc. 510(k) number 2021-11-01 Class II Under Investigation by firm Testing vendor notified Smith & Nephew that previous MRI scanning conditions provided in Exponents reports were erroneous. Erroneous data from the reports was incorporated in the released IFU
81110294 EVOS Large Fragment Plating System.
41 units 2026-06-15
Smith & Nephew, Inc. 510(k) number 2021-10-25 Class II Error in labeling The labels on the packages of screws were switched. 224 units
Smith & Nephew, Inc. 510(k) number 2020-08-24 Class II Error in labeling Multiple or incorrect expiration dates were provided on the affected designation labels. 71 units 2022-07-11
Smith & Nephew, Inc. 510(k) number 2017-12-11 Class II Mixed-up of materials/components Devices, incorrectly labeled as a VLP MINI-MOD 2.0MM STRAIGHT PLATE 8 HOLE, contained a VLP MINI-MOD 2.0MM STOUT PLATE 8 HOLE and vice versa 2 units 2018-06-22
Smith & Nephew, Inc. 510(k) number 2017-12-11 Class II Mixed-up of materials/components Devices, incorrectly labeled as a VLP MINI-MOD 2.0MM STRAIGHT PLATE 8 HOLE, contained a VLP MINI-MOD 2.0MM STOUT PLATE 8 HOLE and vice versa 2 units 2018-06-22
Smith & Nephew, Inc. 510(k) number 2017-11-29 Class II Employee error One lot of EVOS 2.4MM Flex Plate 6 Hole packaging contained templates. 12 2020-09-01

Recalls

5 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2022-01-04 Class II Process control The affected screwdrivers are out of specification and may not mate with the Surfix Alpha Lock screw 8 units (US)
2017-03-22 Class II Mixed-up of materials/components This lot of left plates were laser etched and packaged as right plates. 12 units 2022-06-03
2017-03-09 Class II Labeling Change Control The expiration dates on the labeling are incorrect, the actual expiration dates are before the date on the labeling. 1 unit 2019-08-21
2015-10-20 Class II Employee error The devices were packaged and laser marked anatomically incorrect. The Left plates were laser marked and packaged as Right plates and the Right plates were laser marked and packaged as Left plates. 9 units 2016-09-21
2015-10-20 Class II Employee error The devices were packaged and laser marked anatomically incorrect. The Left plates were laser marked and packaged as Right plates and the Right plates were laser marked and packaged as Left plates. 9 units 2016-09-21
2010-07-20 Not classified Packaging Inner packaging of sterile product was not sealed. Lack of sterility assurance. 10 units 2011-11-17

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer