Oxford® Partial Knee System
55 catalogue numbers from 154341, listed by Biomet Orthopedics, United States, under Prosthesis, Knee, Femorotibial, Semi-Constrained, Cemented, Metal/Polymer. 10 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Jiangsu (6), Shanghai (2), Zhejiang (2). 4 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Paragon Medical Device (Changzhou) Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 53 |
| Canwell Medical Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 42 |
| Suzhou Elite Precision Machinery Co., Ltd. | Kunshan | Jiangsu | Contract manufacturer | 35 |
| Suzhou Ahno Medical Devices Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 17 |
| Zimmer (Shanghai) Medical International Trading Co., Ltd. | Shanghai | Shanghai | Exporter | 106 |
| Zhejiang Biomet Medical Products Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 74 |
| Shanghai JPY ION-Tech Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 70 |
| Changzhou Biomet Medical Devices Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 54 |
| Johnson & Johnson Medical (Depuy – Suzhou) Ltd. | Suzhou | Jiangsu | Manufacturer | 34 |
| Suzhou Microport Orthorecon Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 31 |
Record
| Listed by | Biomet Orthopedics, United States |
|---|---|
| FDA product code | HRY |
| Device type | Prosthesis, Knee, Femorotibial, Semi-Constrained, Cemented, Metal/Polymer |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3530 |
| 510(k) | K133940 |
| Record published | 2015-10-24 |
| Record revised | 2025-05-30 (version 6) |
Specifications
| MRI safety | MR Conditional |
|---|---|
| Supplied sterile | Yes |
| Single use | Yes |
| Prescription | Prescription only |
| Label carries | lot or batch number, expiry date, manufacturing date |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 154341 | Left E4 | In distribution |
| 154331 | Left C4 | In distribution |
| 154347 | Left F5 | In distribution |
| 154324 | Left A7 | In distribution |
| 154362 | Right C5 | In distribution |
| 154340 | Left E3 | In distribution |
| 154377 | Right F5 | In distribution |
| 154321 | Left A4 | In distribution |
| 154335 | Left D3 | In distribution |
| 154338 | Left D6 | In distribution |
| 154332 | Left C5 | In distribution |
| 154345 | Left F3 | In distribution |
| 154379 | Right F7 | In distribution |
| 154330 | Left C3 | In distribution |
| 154366 | Right D4 | In distribution |
| 154353 | Right A6 | In distribution |
| 154327 | Left B5 | In distribution |
| 154354 | Right A7 | In distribution |
| 154367 | Right D5 | In distribution |
| 154368 | Right D6 | In distribution |
| 154351 | Right A4 | In distribution |
| 154376 | Right F4 | In distribution |
| 154348 | Left F6 | In distribution |
| 154374 | Right E7 | In distribution |
| 154375 | Right F3 | In distribution |
| 154333 | Left C6 | In distribution |
| 154334 | Left C7 | In distribution |
| 154337 | Left D5 | In distribution |
| 154350 | Right A3 | In distribution |
| 154361 | Right C4 | In distribution |
| 154370 | Right E3 | In distribution |
| 154358 | Right B6 | In distribution |
| 154339 | Left D7 | In distribution |
| 154373 | Right E6 | In distribution |
| 154352 | Right A5 | In distribution |
| 154344 | Left E7 | In distribution |
| 154372 | Right E5 | In distribution |
| 154343 | Left E6 | In distribution |
| 154359 | Right B7 | In distribution |
| 154323 | Left A6 | In distribution |
| 154378 | Right F6 | In distribution |
| 154325 | Left B3 | In distribution |
| 154371 | Right E4 | In distribution |
| 154363 | Right C6 | In distribution |
| 154357 | Right B5 | In distribution |
| 154346 | Left F4 | In distribution |
| 154342 | Left E5 | In distribution |
| 154356 | Right B4 | In distribution |
| 154369 | Right D7 | In distribution |
| 154322 | Left A5 | In distribution |
| 154360 | Right C3 | In distribution |
| 154364 | Right C7 | In distribution |
| 154355 | Right B3 | In distribution |
| 154365 | Right D3 | In distribution |
| 154329 | Left B7 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Legion | Smith & Nephew, Inc. | 1,682 |
| Genesis II | Smith & Nephew, Inc. | 615 |
| Journey II | Smith & Nephew, Inc. | 581 |
| Evolution | Microport Orthopedics Inc. | 311 |
| Profix | Smith & Nephew, Inc. | 293 |
| Journey | Smith & Nephew, Inc. | 215 |
| LinkSymphoKnee | Waldemar Link GmbH & Co. KG | 201 |
| Prosthesis, Knee, Femorotibial, Semi-Constrained, Cemented, Metal/Polymer | Smith & Nephew, Inc. | 160 |
| JII | Smith & Nephew, Inc. | 141 |
| Physica KR | Limacorporate | 128 |
| Physica LMC | Limacorporate | 120 |
| Implant Partners | Microport Orthopedics Inc. | 119 |
Showing 12 of 160. All products under Prosthesis, Knee, Femorotibial, Semi-Constrained, Cemented, Metal/Polymer
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K020264 | 2002-02-08 |
Recalls Naming This Product
4 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Biomet, Inc. | 510(k) number | 2022-12-15 | Class II | Package design/selection | Packaged in the incorrect shelf carton. Incorrect shelf carton; outer carton is smaller than the required outer carton, which forces the Tyvex pouch to be folded and packaged in the carton causing compound creases and compromise the steril | 7 units | |
| Biomet, Inc. | 510(k) number | 2020-11-25 | Class II | Process control | Specific lots of multiple sterile medical devices may have a breach in the sterile seal. A breach in the packaging seal could lead to loss of sterility of the device. | 7428 | 2024-05-08 |
| Biomet, Inc. | 510(k) number | 2020-04-17 | Class II | Process control | Potential presence of elevated endotoxin levels that exceed the specification limit | 76 units | 2021-06-25 |
| Biomet, Inc. | 510(k) number | 2016-12-06 | Class II | Employee error | Zimmer Biomet is initiating a removal of a single lot of Oxford Fixed Lateral Bearings due to mislabeling. Zimmer Biomet received product complaints reporting that when the package labeled as a Right was opened it actually contained a Left | 12 units distributed | 2017-06-01 |
PMA Approvals
A premarket approval is the full Class III route, granted on clinical evidence rather than on equivalence to an existing device. It is the highest regulatory bar a device of this type can clear.
| PMA number | Decision | Trade name | Approved to |
|---|---|---|---|
| P840049 | 1988-09-30 | P.C.A.(TM) TOTAL KNEE SYSTEM | Howmedica Corp. |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.