Oxford®

66 catalogue numbers from 32-423362, listed by Biomet Orthopedics, United States, under Prosthesis, Knee, Femorotibial, Semi-Constrained, Cemented, Metal/Polymer. 10 manufacturers in China are registered for this product code.

Registry build 21.09.26
10manufacturers in China registered for this device type
66catalogue numbers in this listing
1510(k) clearance

Who Else Makes It

Concentrated in Jiangsu (6), Shanghai (2), Zhejiang (2). 4 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code HRY
Manufacturer City Province Registered as Device types
Paragon Medical Device (Changzhou) Co., Ltd. Changzhou Jiangsu Contract manufacturer 53
Canwell Medical Co., Ltd. Jinhua Zhejiang Contract manufacturer 42
Suzhou Elite Precision Machinery Co., Ltd. Kunshan Jiangsu Contract manufacturer 35
Suzhou Ahno Medical Devices Co., Ltd. Suzhou Jiangsu Contract manufacturer 17
Zimmer (Shanghai) Medical International Trading Co., Ltd. Shanghai Shanghai Exporter 106
Zhejiang Biomet Medical Products Co., Ltd. Jinhua Zhejiang Contract manufacturer 74
Shanghai JPY ION-Tech Co., Ltd. Shanghai Shanghai Contract manufacturer 70
Changzhou Biomet Medical Devices Co., Ltd. Changzhou Jiangsu Contract manufacturer 54
Johnson & Johnson Medical (Depuy – Suzhou) Ltd. Suzhou Jiangsu Manufacturer 34
Suzhou Microport Orthorecon Co., Ltd. Suzhou Jiangsu Contract manufacturer 31

Record

Regulatory record for Oxford®
Listed by Biomet Orthopedics, United States
FDA product code HRY
Device type Prosthesis, Knee, Femorotibial, Semi-Constrained, Cemented, Metal/Polymer
Device class Class 2
Regulation 21 CFR 888.3530
510(k) K133940
Record published 2021-04-02
Record revised 2025-05-30 (version 3)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Sterilisation Moist Heat or Steam Sterilization
Prescription Prescription only
Label carries lot or batch number

Catalogue Numbers

Catalogue numbers for Oxford®
Catalogue number Size Status
32-423362 Size A3 In distribution
32-423029 Size F6 In distribution
32-423018 Size D5 In distribution
32-423385 Size E6 In distribution
32-423012 Size C4 In distribution
32-423334 Size D In distribution
32-423023 Size E5 In distribution
32-423019 Size D6 In distribution
32-423368 Size B4 In distribution
32-423380 Size D6 In distribution
32-423016 Size D3 In distribution
32-423015 Size C7 In distribution
32-423005 Size A7 In distribution
32-423003 Size A5 In distribution
32-423370 Size B6 In distribution
32-423009 Size B6 In distribution
32-423363 Size A4 In distribution
32-423335 Size E In distribution
32-423381 Size D7 In distribution
32-423382 Size E3 In distribution
32-423002 Size A4 In distribution
32-423333 Size C In distribution
32-423369 Size B5 In distribution
32-423332 Size B In distribution
32-423387 Size F3 In distribution
32-423025 Size E7 In distribution
32-423383 Size E4 In distribution
32-423379 Size D5 In distribution
32-423389 Size F5 In distribution
32-423020 Size D7 In distribution
32-423371 Size B7 In distribution
32-423022 Size E4 In distribution
32-423013 Size C5 In distribution
32-423366 Size A7 In distribution
32-423006 Size B3 In distribution
32-423384 Size E5 In distribution
32-423021 Size E3 In distribution
32-423365 Size A6 In distribution
32-423001 Size A3 In distribution
32-423011 Size C3 In distribution
32-423390 Size F6 In distribution
32-423386 Size E7 In distribution
32-423373 Size C4 In distribution
32-423375 Size C6 In distribution
32-423331 Size A In distribution
32-423014 Size C6 In distribution
32-423010 Size B7 In distribution
32-423391 Size F7 In distribution
32-423026 Size F3 In distribution
32-423372 Size C3 In distribution
32-423024 Size E6 In distribution
32-423376 Size C7 In distribution
32-423027 Size F4 In distribution
32-423364 Size A5 In distribution
32-423374 Size C5 In distribution
32-423004 Size A6 In distribution
32-423377 Size D3 In distribution
32-423336 Size F In distribution
32-423367 Size B3 In distribution
32-423007 Size B4 In distribution
32-423378 Size D4 In distribution
32-423008 Size B5 In distribution
32-423028 Size F5 In distribution
32-423017 Size D4 In distribution
32-423030 Size F7 In distribution
32-423388 Size F4 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Legion Smith & Nephew, Inc. 1,682
Genesis II Smith & Nephew, Inc. 615
Journey II Smith & Nephew, Inc. 581
Evolution Microport Orthopedics Inc. 311
Profix Smith & Nephew, Inc. 293
Journey Smith & Nephew, Inc. 215
LinkSymphoKnee Waldemar Link GmbH & Co. KG 201
Prosthesis, Knee, Femorotibial, Semi-Constrained, Cemented, Metal/Polymer Smith & Nephew, Inc. 160
JII Smith & Nephew, Inc. 141
Physica KR Limacorporate 128
Physica LMC Limacorporate 120
Implant Partners Microport Orthopedics Inc. 119

Showing 12 of 160. All products under Prosthesis, Knee, Femorotibial, Semi-Constrained, Cemented, Metal/Polymer

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K020264 2002-02-08

Recalls Naming This Product

34 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of Oxford®
Recalled by Identified by Initiated FDA class Root cause Reason Quantity Closed
Biomet, Inc. 510(k) number 2022-12-15 Class II Package design/selection Packaged in the incorrect shelf carton.
Incorrect shelf carton; outer carton is smaller than the required outer carton, which forces the Tyvex pouch
to be folded and packaged in the carton causing compound creases and compromise the steril
7 units
Biomet, Inc. 510(k) number 2020-11-25 Class II Process control Specific lots of multiple sterile medical devices may have a breach in the sterile seal. A breach in the packaging seal could lead to loss of sterility of the device. 7428 2024-05-08
Biomet, Inc. 510(k) number 2020-04-17 Class II Process control Potential presence of elevated endotoxin levels that exceed the specification limit 76 units 2021-06-25
Biomet, Inc. 510(k) number 2016-12-06 Class II Employee error Zimmer Biomet is initiating a removal of a single lot of Oxford Fixed Lateral Bearings due to mislabeling. Zimmer Biomet received product complaints reporting that when the package labeled as a Right was opened it actually contained a Left 12 units distributed 2017-06-01
Biomet, Inc. 510(k) number 2013-06-07 Class II Device Design Biomet investigation found the design of the tibial bearing creates the potential for anterior impingement between the bone and the poly bearing component in terminal extension. 26 2014-07-17
Biomet, Inc. 510(k) number 2013-06-07 Class II Device Design Biomet investigation found the design of the tibial bearing creates the potential for anterior impingement between the bone and the poly bearing component in terminal extension. 22 2014-07-17
Biomet, Inc. 510(k) number 2013-06-07 Class II Device Design Biomet investigation found the design of the tibial bearing creates the potential for anterior impingement between the bone and the poly bearing component in terminal extension. 28 2014-07-17
Biomet, Inc. 510(k) number 2013-06-07 Class II Device Design Biomet investigation found the design of the tibial bearing creates the potential for anterior impingement between the bone and the poly bearing component in terminal extension. 30 2014-07-17
Biomet, Inc. 510(k) number 2013-06-07 Class II Device Design Biomet investigation found the design of the tibial bearing creates the potential for anterior impingement between the bone and the poly bearing component in terminal extension. 22 2014-07-17
Biomet, Inc. 510(k) number 2013-06-07 Class II Device Design Biomet investigation found the design of the tibial bearing creates the potential for anterior impingement between the bone and the poly bearing component in terminal extension. 25 2014-07-17
Biomet, Inc. 510(k) number 2013-06-07 Class II Device Design Biomet investigation found the design of the tibial bearing creates the potential for anterior impingement between the bone and the poly bearing component in terminal extension. 24 2014-07-17
Biomet, Inc. 510(k) number 2013-06-07 Class II Device Design Biomet investigation found the design of the tibial bearing creates the potential for anterior impingement between the bone and the poly bearing component in terminal extension. 23 2014-07-17
Biomet, Inc. 510(k) number 2013-06-07 Class II Device Design Biomet investigation found the design of the tibial bearing creates the potential for anterior impingement between the bone and the poly bearing component in terminal extension. 22 2014-07-17
Biomet, Inc. 510(k) number 2013-06-07 Class II Device Design Biomet investigation found the design of the tibial bearing creates the potential for anterior impingement between the bone and the poly bearing component in terminal extension. 22 2014-07-17
Biomet, Inc. 510(k) number 2013-06-07 Class II Device Design Biomet investigation found the design of the tibial bearing creates the potential for anterior impingement between the bone and the poly bearing component in terminal extension. 32 2014-07-17
Biomet, Inc. 510(k) number 2013-06-07 Class II Device Design Biomet investigation found the design of the tibial bearing creates the potential for anterior impingement between the bone and the poly bearing component in terminal extension. 30 2014-07-17
Biomet, Inc. 510(k) number 2013-06-07 Class II Device Design Biomet investigation found the design of the tibial bearing creates the potential for anterior impingement between the bone and the poly bearing component in terminal extension. 23 2014-07-17
Biomet, Inc. 510(k) number 2013-06-07 Class II Device Design Biomet investigation found the design of the tibial bearing creates the potential for anterior impingement between the bone and the poly bearing component in terminal extension. 24 2014-07-17
Biomet, Inc. 510(k) number 2013-06-07 Class II Device Design Biomet investigation found the design of the tibial bearing creates the potential for anterior impingement between the bone and the poly bearing component in terminal extension. 20 2014-07-17
Biomet, Inc. 510(k) number 2013-06-07 Class II Device Design Biomet investigation found the design of the tibial bearing creates the potential for anterior impingement between the bone and the poly bearing component in terminal extension. 29 2014-07-17
Biomet, Inc. 510(k) number 2013-06-07 Class II Device Design Biomet investigation found the design of the tibial bearing creates the potential for anterior impingement between the bone and the poly bearing component in terminal extension. 37 2014-07-17
Biomet, Inc. 510(k) number 2013-06-07 Class II Device Design Biomet investigation found the design of the tibial bearing creates the potential for anterior impingement between the bone and the poly bearing component in terminal extension. 46 2014-07-17
Biomet, Inc. 510(k) number 2013-06-07 Class II Device Design Biomet investigation found the design of the tibial bearing creates the potential for anterior impingement between the bone and the poly bearing component in terminal extension. 26 2014-07-17
Biomet, Inc. 510(k) number 2013-06-07 Class II Device Design Biomet investigation found the design of the tibial bearing creates the potential for anterior impingement between the bone and the poly bearing component in terminal extension. 26 2014-07-17
Biomet, Inc. 510(k) number 2013-06-07 Class II Device Design Biomet investigation found the design of the tibial bearing creates the potential for anterior impingement between the bone and the poly bearing component in terminal extension. 25 2014-07-17
Biomet, Inc. 510(k) number 2013-06-07 Class II Device Design Biomet investigation found the design of the tibial bearing creates the potential for anterior impingement between the bone and the poly bearing component in terminal extension. 25 2014-07-17
Biomet, Inc. 510(k) number 2013-06-07 Class II Device Design Biomet investigation found the design of the tibial bearing creates the potential for anterior impingement between the bone and the poly bearing component in terminal extension. 25 2014-07-17
Biomet, Inc. 510(k) number 2013-06-07 Class II Device Design Biomet investigation found the design of the tibial bearing creates the potential for anterior impingement between the bone and the poly bearing component in terminal extension. 28 2014-07-17
Biomet, Inc. 510(k) number 2013-06-07 Class II Device Design Biomet investigation found the design of the tibial bearing creates the potential for anterior impingement between the bone and the poly bearing component in terminal extension. 31 2014-07-17
Biomet, Inc. 510(k) number 2013-06-07 Class II Device Design Biomet investigation found the design of the tibial bearing creates the potential for anterior impingement between the bone and the poly bearing component in terminal extension. 26 2014-07-17
Biomet, Inc. 510(k) number 2013-06-07 Class II Device Design Biomet investigation found the design of the tibial bearing creates the potential for anterior impingement between the bone and the poly bearing component in terminal extension. 25 2014-07-17
Biomet, Inc. 510(k) number 2013-06-07 Class II Device Design Biomet investigation found the design of the tibial bearing creates the potential for anterior impingement between the bone and the poly bearing component in terminal extension. 23 2014-07-17
Biomet, Inc. 510(k) number 2013-06-07 Class II Device Design Biomet investigation found the design of the tibial bearing creates the potential for anterior impingement between the bone and the poly bearing component in terminal extension. 25 2014-07-17
Biomet, Inc. 510(k) number 2013-06-07 Class II Device Design Biomet investigation found the design of the tibial bearing creates the potential for anterior impingement between the bone and the poly bearing component in terminal extension. 24 2014-07-17

PMA Approvals

A premarket approval is the full Class III route, granted on clinical evidence rather than on equivalence to an existing device. It is the highest regulatory bar a device of this type can clear.

FDA premarket approvals naming this product code
PMA number Decision Trade name Approved to
P840049 1988-09-30 P.C.A.(TM) TOTAL KNEE SYSTEM Howmedica Corp.

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer