Oxford®
66 catalogue numbers from 32-423362, listed by Biomet Orthopedics, United States, under Prosthesis, Knee, Femorotibial, Semi-Constrained, Cemented, Metal/Polymer. 10 manufacturers in China are registered for this product code.
Who Else Makes It
Concentrated in Jiangsu (6), Shanghai (2), Zhejiang (2). 4 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Paragon Medical Device (Changzhou) Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 53 |
| Canwell Medical Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 42 |
| Suzhou Elite Precision Machinery Co., Ltd. | Kunshan | Jiangsu | Contract manufacturer | 35 |
| Suzhou Ahno Medical Devices Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 17 |
| Zimmer (Shanghai) Medical International Trading Co., Ltd. | Shanghai | Shanghai | Exporter | 106 |
| Zhejiang Biomet Medical Products Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 74 |
| Shanghai JPY ION-Tech Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 70 |
| Changzhou Biomet Medical Devices Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 54 |
| Johnson & Johnson Medical (Depuy – Suzhou) Ltd. | Suzhou | Jiangsu | Manufacturer | 34 |
| Suzhou Microport Orthorecon Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 31 |
Record
| Listed by | Biomet Orthopedics, United States |
|---|---|
| FDA product code | HRY |
| Device type | Prosthesis, Knee, Femorotibial, Semi-Constrained, Cemented, Metal/Polymer |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3530 |
| 510(k) | K133940 |
| Record published | 2021-04-02 |
| Record revised | 2025-05-30 (version 3) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Sterilisation | Moist Heat or Steam Sterilization |
| Prescription | Prescription only |
| Label carries | lot or batch number |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 32-423362 | Size A3 | In distribution |
| 32-423029 | Size F6 | In distribution |
| 32-423018 | Size D5 | In distribution |
| 32-423385 | Size E6 | In distribution |
| 32-423012 | Size C4 | In distribution |
| 32-423334 | Size D | In distribution |
| 32-423023 | Size E5 | In distribution |
| 32-423019 | Size D6 | In distribution |
| 32-423368 | Size B4 | In distribution |
| 32-423380 | Size D6 | In distribution |
| 32-423016 | Size D3 | In distribution |
| 32-423015 | Size C7 | In distribution |
| 32-423005 | Size A7 | In distribution |
| 32-423003 | Size A5 | In distribution |
| 32-423370 | Size B6 | In distribution |
| 32-423009 | Size B6 | In distribution |
| 32-423363 | Size A4 | In distribution |
| 32-423335 | Size E | In distribution |
| 32-423381 | Size D7 | In distribution |
| 32-423382 | Size E3 | In distribution |
| 32-423002 | Size A4 | In distribution |
| 32-423333 | Size C | In distribution |
| 32-423369 | Size B5 | In distribution |
| 32-423332 | Size B | In distribution |
| 32-423387 | Size F3 | In distribution |
| 32-423025 | Size E7 | In distribution |
| 32-423383 | Size E4 | In distribution |
| 32-423379 | Size D5 | In distribution |
| 32-423389 | Size F5 | In distribution |
| 32-423020 | Size D7 | In distribution |
| 32-423371 | Size B7 | In distribution |
| 32-423022 | Size E4 | In distribution |
| 32-423013 | Size C5 | In distribution |
| 32-423366 | Size A7 | In distribution |
| 32-423006 | Size B3 | In distribution |
| 32-423384 | Size E5 | In distribution |
| 32-423021 | Size E3 | In distribution |
| 32-423365 | Size A6 | In distribution |
| 32-423001 | Size A3 | In distribution |
| 32-423011 | Size C3 | In distribution |
| 32-423390 | Size F6 | In distribution |
| 32-423386 | Size E7 | In distribution |
| 32-423373 | Size C4 | In distribution |
| 32-423375 | Size C6 | In distribution |
| 32-423331 | Size A | In distribution |
| 32-423014 | Size C6 | In distribution |
| 32-423010 | Size B7 | In distribution |
| 32-423391 | Size F7 | In distribution |
| 32-423026 | Size F3 | In distribution |
| 32-423372 | Size C3 | In distribution |
| 32-423024 | Size E6 | In distribution |
| 32-423376 | Size C7 | In distribution |
| 32-423027 | Size F4 | In distribution |
| 32-423364 | Size A5 | In distribution |
| 32-423374 | Size C5 | In distribution |
| 32-423004 | Size A6 | In distribution |
| 32-423377 | Size D3 | In distribution |
| 32-423336 | Size F | In distribution |
| 32-423367 | Size B3 | In distribution |
| 32-423007 | Size B4 | In distribution |
| 32-423378 | Size D4 | In distribution |
| 32-423008 | Size B5 | In distribution |
| 32-423028 | Size F5 | In distribution |
| 32-423017 | Size D4 | In distribution |
| 32-423030 | Size F7 | In distribution |
| 32-423388 | Size F4 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| Legion | Smith & Nephew, Inc. | 1,682 |
| Genesis II | Smith & Nephew, Inc. | 615 |
| Journey II | Smith & Nephew, Inc. | 581 |
| Evolution | Microport Orthopedics Inc. | 311 |
| Profix | Smith & Nephew, Inc. | 293 |
| Journey | Smith & Nephew, Inc. | 215 |
| LinkSymphoKnee | Waldemar Link GmbH & Co. KG | 201 |
| Prosthesis, Knee, Femorotibial, Semi-Constrained, Cemented, Metal/Polymer | Smith & Nephew, Inc. | 160 |
| JII | Smith & Nephew, Inc. | 141 |
| Physica KR | Limacorporate | 128 |
| Physica LMC | Limacorporate | 120 |
| Implant Partners | Microport Orthopedics Inc. | 119 |
Showing 12 of 160. All products under Prosthesis, Knee, Femorotibial, Semi-Constrained, Cemented, Metal/Polymer
510(K) Clearances
| Clearance | Decision date |
|---|---|
| K020264 | 2002-02-08 |
Recalls Naming This Product
34 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Biomet, Inc. | 510(k) number | 2022-12-15 | Class II | Package design/selection | Packaged in the incorrect shelf carton. Incorrect shelf carton; outer carton is smaller than the required outer carton, which forces the Tyvex pouch to be folded and packaged in the carton causing compound creases and compromise the steril | 7 units | |
| Biomet, Inc. | 510(k) number | 2020-11-25 | Class II | Process control | Specific lots of multiple sterile medical devices may have a breach in the sterile seal. A breach in the packaging seal could lead to loss of sterility of the device. | 7428 | 2024-05-08 |
| Biomet, Inc. | 510(k) number | 2020-04-17 | Class II | Process control | Potential presence of elevated endotoxin levels that exceed the specification limit | 76 units | 2021-06-25 |
| Biomet, Inc. | 510(k) number | 2016-12-06 | Class II | Employee error | Zimmer Biomet is initiating a removal of a single lot of Oxford Fixed Lateral Bearings due to mislabeling. Zimmer Biomet received product complaints reporting that when the package labeled as a Right was opened it actually contained a Left | 12 units distributed | 2017-06-01 |
| Biomet, Inc. | 510(k) number | 2013-06-07 | Class II | Device Design | Biomet investigation found the design of the tibial bearing creates the potential for anterior impingement between the bone and the poly bearing component in terminal extension. | 26 | 2014-07-17 |
| Biomet, Inc. | 510(k) number | 2013-06-07 | Class II | Device Design | Biomet investigation found the design of the tibial bearing creates the potential for anterior impingement between the bone and the poly bearing component in terminal extension. | 22 | 2014-07-17 |
| Biomet, Inc. | 510(k) number | 2013-06-07 | Class II | Device Design | Biomet investigation found the design of the tibial bearing creates the potential for anterior impingement between the bone and the poly bearing component in terminal extension. | 28 | 2014-07-17 |
| Biomet, Inc. | 510(k) number | 2013-06-07 | Class II | Device Design | Biomet investigation found the design of the tibial bearing creates the potential for anterior impingement between the bone and the poly bearing component in terminal extension. | 30 | 2014-07-17 |
| Biomet, Inc. | 510(k) number | 2013-06-07 | Class II | Device Design | Biomet investigation found the design of the tibial bearing creates the potential for anterior impingement between the bone and the poly bearing component in terminal extension. | 22 | 2014-07-17 |
| Biomet, Inc. | 510(k) number | 2013-06-07 | Class II | Device Design | Biomet investigation found the design of the tibial bearing creates the potential for anterior impingement between the bone and the poly bearing component in terminal extension. | 25 | 2014-07-17 |
| Biomet, Inc. | 510(k) number | 2013-06-07 | Class II | Device Design | Biomet investigation found the design of the tibial bearing creates the potential for anterior impingement between the bone and the poly bearing component in terminal extension. | 24 | 2014-07-17 |
| Biomet, Inc. | 510(k) number | 2013-06-07 | Class II | Device Design | Biomet investigation found the design of the tibial bearing creates the potential for anterior impingement between the bone and the poly bearing component in terminal extension. | 23 | 2014-07-17 |
| Biomet, Inc. | 510(k) number | 2013-06-07 | Class II | Device Design | Biomet investigation found the design of the tibial bearing creates the potential for anterior impingement between the bone and the poly bearing component in terminal extension. | 22 | 2014-07-17 |
| Biomet, Inc. | 510(k) number | 2013-06-07 | Class II | Device Design | Biomet investigation found the design of the tibial bearing creates the potential for anterior impingement between the bone and the poly bearing component in terminal extension. | 22 | 2014-07-17 |
| Biomet, Inc. | 510(k) number | 2013-06-07 | Class II | Device Design | Biomet investigation found the design of the tibial bearing creates the potential for anterior impingement between the bone and the poly bearing component in terminal extension. | 32 | 2014-07-17 |
| Biomet, Inc. | 510(k) number | 2013-06-07 | Class II | Device Design | Biomet investigation found the design of the tibial bearing creates the potential for anterior impingement between the bone and the poly bearing component in terminal extension. | 30 | 2014-07-17 |
| Biomet, Inc. | 510(k) number | 2013-06-07 | Class II | Device Design | Biomet investigation found the design of the tibial bearing creates the potential for anterior impingement between the bone and the poly bearing component in terminal extension. | 23 | 2014-07-17 |
| Biomet, Inc. | 510(k) number | 2013-06-07 | Class II | Device Design | Biomet investigation found the design of the tibial bearing creates the potential for anterior impingement between the bone and the poly bearing component in terminal extension. | 24 | 2014-07-17 |
| Biomet, Inc. | 510(k) number | 2013-06-07 | Class II | Device Design | Biomet investigation found the design of the tibial bearing creates the potential for anterior impingement between the bone and the poly bearing component in terminal extension. | 20 | 2014-07-17 |
| Biomet, Inc. | 510(k) number | 2013-06-07 | Class II | Device Design | Biomet investigation found the design of the tibial bearing creates the potential for anterior impingement between the bone and the poly bearing component in terminal extension. | 29 | 2014-07-17 |
| Biomet, Inc. | 510(k) number | 2013-06-07 | Class II | Device Design | Biomet investigation found the design of the tibial bearing creates the potential for anterior impingement between the bone and the poly bearing component in terminal extension. | 37 | 2014-07-17 |
| Biomet, Inc. | 510(k) number | 2013-06-07 | Class II | Device Design | Biomet investigation found the design of the tibial bearing creates the potential for anterior impingement between the bone and the poly bearing component in terminal extension. | 46 | 2014-07-17 |
| Biomet, Inc. | 510(k) number | 2013-06-07 | Class II | Device Design | Biomet investigation found the design of the tibial bearing creates the potential for anterior impingement between the bone and the poly bearing component in terminal extension. | 26 | 2014-07-17 |
| Biomet, Inc. | 510(k) number | 2013-06-07 | Class II | Device Design | Biomet investigation found the design of the tibial bearing creates the potential for anterior impingement between the bone and the poly bearing component in terminal extension. | 26 | 2014-07-17 |
| Biomet, Inc. | 510(k) number | 2013-06-07 | Class II | Device Design | Biomet investigation found the design of the tibial bearing creates the potential for anterior impingement between the bone and the poly bearing component in terminal extension. | 25 | 2014-07-17 |
| Biomet, Inc. | 510(k) number | 2013-06-07 | Class II | Device Design | Biomet investigation found the design of the tibial bearing creates the potential for anterior impingement between the bone and the poly bearing component in terminal extension. | 25 | 2014-07-17 |
| Biomet, Inc. | 510(k) number | 2013-06-07 | Class II | Device Design | Biomet investigation found the design of the tibial bearing creates the potential for anterior impingement between the bone and the poly bearing component in terminal extension. | 25 | 2014-07-17 |
| Biomet, Inc. | 510(k) number | 2013-06-07 | Class II | Device Design | Biomet investigation found the design of the tibial bearing creates the potential for anterior impingement between the bone and the poly bearing component in terminal extension. | 28 | 2014-07-17 |
| Biomet, Inc. | 510(k) number | 2013-06-07 | Class II | Device Design | Biomet investigation found the design of the tibial bearing creates the potential for anterior impingement between the bone and the poly bearing component in terminal extension. | 31 | 2014-07-17 |
| Biomet, Inc. | 510(k) number | 2013-06-07 | Class II | Device Design | Biomet investigation found the design of the tibial bearing creates the potential for anterior impingement between the bone and the poly bearing component in terminal extension. | 26 | 2014-07-17 |
| Biomet, Inc. | 510(k) number | 2013-06-07 | Class II | Device Design | Biomet investigation found the design of the tibial bearing creates the potential for anterior impingement between the bone and the poly bearing component in terminal extension. | 25 | 2014-07-17 |
| Biomet, Inc. | 510(k) number | 2013-06-07 | Class II | Device Design | Biomet investigation found the design of the tibial bearing creates the potential for anterior impingement between the bone and the poly bearing component in terminal extension. | 23 | 2014-07-17 |
| Biomet, Inc. | 510(k) number | 2013-06-07 | Class II | Device Design | Biomet investigation found the design of the tibial bearing creates the potential for anterior impingement between the bone and the poly bearing component in terminal extension. | 25 | 2014-07-17 |
| Biomet, Inc. | 510(k) number | 2013-06-07 | Class II | Device Design | Biomet investigation found the design of the tibial bearing creates the potential for anterior impingement between the bone and the poly bearing component in terminal extension. | 24 | 2014-07-17 |
PMA Approvals
A premarket approval is the full Class III route, granted on clinical evidence rather than on equivalence to an existing device. It is the highest regulatory bar a device of this type can clear.
| PMA number | Decision | Trade name | Approved to |
|---|---|---|---|
| P840049 | 1988-09-30 | P.C.A.(TM) TOTAL KNEE SYSTEM | Howmedica Corp. |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.