EXPert
Radiolucent Insertion Handle FOR Expert ALFN/100MM
Who Else Makes It
Concentrated in Jiangsu (7), Shanghai (3), Zhejiang (3). 10 of them are registered as contract manufacturers, able to build to a buyer’s own specification.
| Manufacturer | City | Province | Registered as | Device types |
|---|---|---|---|---|
| Zhejiang Biomet Medical Products Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 74 |
| Apex (Guangzhou) Tools & Orthopedics Company | Guangzhou | Guangdong | Contract manufacturer | 62 |
| Changzhou Biomet Medical Devices Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 54 |
| Paragon Medical Device (Changzhou) Co., Ltd. | Changzhou | Jiangsu | Contract manufacturer | 53 |
| Canwell Medical Co., Ltd. | Jinhua | Zhejiang | Contract manufacturer | 42 |
| LX Precision Shanghai Co Ltd | Shanghai | Shanghai | Contract manufacturer | 19 |
| Stryker (Suzhou) Medical Technology Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 19 |
| Suzhou Ahno Medical Devices Co., Ltd. | Suzhou | Jiangsu | Contract manufacturer | 17 |
| Turnxon Precision Co., Ltd. | Dongguan | Guangdong | Contract manufacturer | 17 |
| Suzhou Kangli Orthopaedics Instrument Co., Ltd. | Zhangjiagang | Jiangsu | Contract manufacturer | 11 |
| Zimmer (Shanghai) Medical International Trading Co., Ltd. | Shanghai | Shanghai | Exporter | 106 |
| Shanghai JPY ION-Tech Co., Ltd. | Shanghai | Shanghai | Contract manufacturer | 70 |
Showing 12 of 17. All 17 manufacturers in China registered for Rod, Fixation, Intramedullary And Accessories
Record
| Listed by | Synthes Gmbh, Switzerland |
|---|---|
| FDA product code | HSB |
| Device type | Rod, Fixation, Intramedullary And Accessories |
| Device class | Class 2 |
| Regulation | 21 CFR 888.3020 |
| Establishment | Specification developer, Manufacturer, Exporter |
| 510(k) | K070843 |
| Record published | 2015-09-14 |
| Record revised | 2022-04-28 (version 7) |
Specifications
| MRI safety | Labeling does not contain MRI Safety Information |
|---|---|
| Sterilisation | Moist Heat or Steam Sterilization |
| Prescription | Prescription only |
| Label carries | lot or batch number |
Catalogue Numbers
| Catalogue number | Size | Status |
|---|---|---|
| 03.010.483 | In distribution | |
| 03.010.482 | In distribution | |
| 03.010.488 | In distribution | |
| 03.010.509 | In distribution | |
| 03.010.505 | In distribution | |
| 03.010.504 | In distribution | |
| 03.010.510 | In distribution |
Same Product Code
| Product | Sold by | Catalogue numbers |
|---|---|---|
| T2 | Stryker GmbH | 1,373 |
| Autobahn | Globus Medical, Inc. | 1,258 |
| Gamma | Stryker GmbH | 1,120 |
| Summa Orthopaedics Femur Nail System | Jeil Medical Corporation | 742 |
| Arix Femur Nail System | Jeil Medical Corporation | 742 |
| Orthofix | Orthofix SRL | 721 |
| Rod, Fixation, Intramedullary And Accessories | Synthes Gmbh | 715 |
| Trigen | Smith & Nephew, Inc. | 681 |
| Arthrex® | Arthrex, Inc. | 665 |
| Precice® Intramedullary Limb Lengthening System | NuVasive Specialized Orthopedics, Inc. | 596 |
| Apex | Orthoxel Designated Activity Company | 569 |
| Natural Nail® | Zimmer, Inc. | 552 |
Showing 12 of 2,207. All products under Rod, Fixation, Intramedullary And Accessories
Recalls Naming This Product
2 recalls name this product by its own identifiers, the 510(k) it is cleared under.
| Recalled by | Identified by | Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|---|---|
| Synthes Gmbh | 510(k) number | 2015-05-27 | Class II | Process control | certain lots of the Titanium Recon Screws (6.5mm ) were found to contain the incorrect insert GP0760-A (Synthes Titanium Buttress Locking Plate System), instead of the correct insert GP0706-E (Synthes Titanium Intramedullary Nails and Compo | 276 | 2015-12-18 |
| Synthes USA (HQ), Inc. | 510(k) number | 2012-11-02 | Class II | Packaging change control | Recall was initiated due to the possibility that the outer pouch was compromised. The product is packaged in two pouches; a sterile, internal pouch within an external pouch. It is the outer, external pouch that may be compromised. | 1,011,783 | 2016-09-27 |
Recalls
3 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.
| Initiated | FDA class | Root cause | Reason | Quantity | Closed |
|---|---|---|---|---|---|
| 2015-04-09 | Class II | Process control | TFNA nails from certain lots were assembled with a locking mechanism too close to the top of the nail. Potential patient impact: surgical delay. | 8175 | 2016-08-18 |
| 2015-02-24 | Class II | Component design/selection | The guide sleeve has the potential to jam in the Aiming Arms, which may delay disassembly and removal of instruments. | 131 | 2015-09-21 |
| 2014-10-29 | Class II | Employee error | The 10 mm/135 degree Titanium Cannulated Trochanteric Fixation Nail 170 MM (Sterile) was assembled incorrectly. If the non conformance goes undetected, it may impact the locking function post-operatively and compromise the bone reduction an | 6 | 2015-12-18 |
Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability.
Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.