Precice® Stryde System

PRECICE Stryde is an intramedullary nail system for controlled limb lengthening or compression and internal fixation of long bones. A telescoping distraction rod changes the length of the…

Registry build 21.09.26

PRECICE Stryde is an intramedullary nail system for controlled limb lengthening or compression and internal fixation of long bones. A telescoping distraction rod changes the length of the implanted nail.

An enclosed rare-earth magnet and planetary gearing translate the external remote controller’s input into adjustment of the telescoping mechanism. Locking screws and end caps secure the nail as part of the implanted construct.

Listed Item

Antegrade Femur Piriformis Straight Nail

Surgical Components

The range includes different nail diameters, lengths and screw-hole arrangements, with compatible locking screws and external-controller models. Nails and end caps are supplied sterile; locking screws and reusable surgical instruments are supplied nonsterile and require sterilization before use.

17manufacturers in China registered for this device type
177catalogue numbers in this listing
18510(k) clearances naming this product code
9recalls on this code

Who Else Makes It

Concentrated in Jiangsu (7), Shanghai (3), Zhejiang (3). 10 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code HSB
Manufacturer City Province Registered as Device types
Zhejiang Biomet Medical Products Co., Ltd. Jinhua Zhejiang Contract manufacturer 74
Apex (Guangzhou) Tools & Orthopedics Company Guangzhou Guangdong Contract manufacturer 62
Changzhou Biomet Medical Devices Co., Ltd. Changzhou Jiangsu Contract manufacturer 54
Paragon Medical Device (Changzhou) Co., Ltd. Changzhou Jiangsu Contract manufacturer 53
Canwell Medical Co., Ltd. Jinhua Zhejiang Contract manufacturer 42
LX Precision Shanghai Co Ltd Shanghai Shanghai Contract manufacturer 19
Stryker (Suzhou) Medical Technology Co., Ltd. Suzhou Jiangsu Contract manufacturer 19
Suzhou Ahno Medical Devices Co., Ltd. Suzhou Jiangsu Contract manufacturer 17
Turnxon Precision Co., Ltd. Dongguan Guangdong Contract manufacturer 17
Suzhou Kangli Orthopaedics Instrument Co., Ltd. Zhangjiagang Jiangsu Contract manufacturer 11
Zimmer (Shanghai) Medical International Trading Co., Ltd. Shanghai Shanghai Exporter 106
Shanghai JPY ION-Tech Co., Ltd. Shanghai Shanghai Contract manufacturer 70

Showing 12 of 17. All 17 manufacturers in China registered for Rod, Fixation, Intramedullary And Accessories

Record

Regulatory record for Precice® Stryde System
Listed by NuVasive Specialized Orthopedics, Inc., United States
FDA product code HSB
Device type Rod, Fixation, Intramedullary And Accessories
Device class Class 2
Regulation 21 CFR 888.3020
Establishment Manufacturer, Exporter
510(k) K180503
Record published 2018-09-26
Record revised 2025-05-28 (version 8)

Specifications

Specifications
MRI safety MR Unsafe
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date, manufacturing date
Sizes Outer diameter 10 to 13 mm; circumference 10 mm

Catalogue Numbers

Catalogue numbers for Precice® Stryde System
Catalogue number Size Status
PS10.0-80V365 Outer Diameter 10.0 mm In distribution
PS10.0-80A305 Outer Diameter 10.0 mm In distribution
PS13.0-65D250 Outer Diameter 13.0 mm In distribution
PS13.0-80V265 Outer Diameter 13.0 mm In distribution
SST-013-015 Outer Diameter 13.0 mm In distribution
PS13.0-65SJ250 Outer Diameter 13.0 mm In distribution
PS11.5-80SJ265 Outer Diameter 11.5 mm In distribution
PS13.0-80SJ335 Outer Diameter 13.0 mm In distribution
PS13.0-80C335 Outer Diameter 13.0 mm In distribution
PS10.0-80X265 Outer Diameter 10.0 mm In distribution
PS13.0-80V305 Outer Diameter 13.0 mm In distribution
PS11.5-80A305 Outer Diameter 11.5 mm In distribution
PS13.0-80B365 Outer Diameter 13.0 mm In distribution
PS11.5-80V335 Outer Diameter 11.5 mm In distribution
PS13.0-80A305 Outer Diameter 13.0 mm In distribution
PS11.5-80X335 Outer Diameter 11.5 mm In distribution
PS10.0-65C250 Outer Diameter 11.5 mm In distribution
PS13.0-80C280 Outer Diameter 13.0 mm In distribution
PS11.5-80B365 Outer Diameter 11.5 mm In distribution
PS13.0-65E250 Outer Diameter 13.0 mm In distribution
PS13.0-80E365 Outer Diameter 13.0 mm In distribution
PS13.0-50X235 Outer Diameter 13.0 mm In distribution
PS13.0-80D280 Outer Diameter 13.0 mm In distribution
PS11.5-65X250 Outer Diameter 11.5 mm In distribution
PS10.0-80C335 Outer Diameter 10.0 mm In distribution
PS11.5-80SJ335 Outer Diameter 11.5 mm In distribution
PS11.5-80D280 Outer Diameter 11.5 mm In distribution
PS10.0-80X280 Outer Diameter 10.0 mm In distribution
PS11.5-80C365 Outer Diameter 11.5 mm In distribution
PS11.5-80V280 Outer Diameter 11.5 mm In distribution
PS13.0-80B280 Outer Diameter 13.0 mm In distribution
PS10.0-65V250 Outer Diameter 13.0 mm In distribution
PS10.0-80A280 Outer Diameter 10.0 mm In distribution
SST-010-000 In distribution
PS10.0-80E305 Outer Diameter 10.0 mm In distribution
PS10.0-50X235 Outer Diameter 11.5 mm In distribution
PS11.5-50B235 Outer Diameter 11.5 mm In distribution
PS13.0-80V365 Outer Diameter 13.0 mm In distribution
PS10.0-80C280 Outer Diameter 10.0 mm In distribution
PS11.5-65V250 Outer Diameter 11.5 mm In distribution
PS11.5-80C305 Outer Diameter 11.5 mm In distribution
PS11.5-65D250 Outer Diameter 11.5 mm In distribution
PS11.5-50X235 Outer Diameter 11.5 mm In distribution
PS11.5-80D265 Outer Diameter 11.5 mm In distribution
PS11.5-80D305 Outer Diameter 11.5 mm In distribution
PS11.5-80X265 Outer Diameter 11.5 mm In distribution
PS10.0-80D365 Outer Diameter 10.0 mm In distribution
PS11.5-80B265 Outer Diameter 11.5 mm In distribution
PS11.5-50E235 Outer Diameter 11.5 mm In distribution
PS13.0-80C265 Outer Diameter 13.0 mm In distribution
PS11.5-80B305 Outer Diameter 11.5 mm In distribution
PS11.5-80E280 Outer Diameter 11.5 mm In distribution
PS11.5-80E265 Outer Diameter 11.5 mm In distribution
PS13.0-80SJ280 Outer Diameter 13.0 mm In distribution
SST-013-010 Outer Diameter 13.0 mm In distribution
PS10.0-65A250 Outer Diameter 11.5 mm In distribution
PS13.0-80V280 Outer Diameter 13.0 mm In distribution
PS13.0-80A280 Outer Diameter 13.0 mm In distribution
PS10.0-50V235 Outer Diameter 10 mm In distribution
PS11.5-50V235 Outer Diameter 11.5 mm In distribution
PS11.5-80E305 Outer Diameter 11.5 mm In distribution
PS11.5-80D335 Outer Diameter 11.5 mm In distribution
PS10.0-80SJ280 Outer Diameter 10.0 mm In distribution
PS10.0-80V305 Outer Diameter 10.0 mm In distribution
PS10.0-80V280 Outer Diameter 10.0 mm In distribution
PS10.0-80D280 Outer Diameter 10.0 mm In distribution
PS13.0-80B265 Outer Diameter 13.0 mm In distribution
PS10.0-80E265 Outer Diameter 10.0 mm In distribution
SST-013-000 In distribution
PS13.0-65A250 Outer Diameter 13.0 mm In distribution
PS13.0-80V335 Outer Diameter 13.0 mm In distribution
SST-013-020 Outer Diameter 13.0 mm In distribution
PS13.0-80D365 Outer Diameter 13.0 mm In distribution
PS13.0-65C250 Outer Diameter 13.0 mm In distribution
PS10.0-65X250 Outer Diameter 10.0 mm In distribution
PS10.0-65D250 Outer Diameter 11.5 mm In distribution
PS10.0-80X335 Outer Diameter 10.0 mm In distribution
PS10.0-80V335 Outer Diameter 10.0 mm In distribution
PS10.0-80SJ365 Outer Diameter 10.0 mm In distribution
PS13.0-50A235 Outer Diameter 13.0 mm In distribution
PS10.0-80B280 Outer Diameter 10.0 mm In distribution
PS11.5-50SJ235 Outer Diameter 11.5 mm In distribution
PS13.0-50C235 Outer Diameter 13.0 mm In distribution
SST-010-005 Outer Diameter 10.0 mm In distribution
PS13.0-80SJ265 Outer Diameter 13.0 mm In distribution
PS10.0-80D265 Outer Diameter 10.0 mm In distribution
PS10.0-80B305 Outer Diameter 10.0 mm In distribution
PS11.5-50D235 Outer Diameter 11.5 mm In distribution
PS11.5-80D365 Outer Diameter 11.5 mm In distribution
PS13.0-80X280 Outer Diameter 13.0 mm In distribution
PS11.5-80X280 Outer Diameter 11.5 mm In distribution
PS11.5-80X305 Outer Diameter 11.5 mm In distribution
PS13.0-80E280 Outer Diameter 13.0 mm In distribution
PS10.0-80C265 Outer Diameter 10.0 mm In distribution
PS10.0-80A365 Outer Diameter 10.0 mm In distribution
PS13.0-80E335 Outer Diameter 13.0 mm In distribution
PS13.0-80X365 Outer Diameter 13.0 mm In distribution
PS10.0-80E280 Outer Diameter 10.0 mm In distribution
PS11.5-80C265 Outer Diameter 11.5 mm In distribution
PS13.0-80C365 Outer Diameter 13.0 mm In distribution
PS13.0-80D335 Outer Diameter 13.0 mm In distribution
PS10.0-80SJ265 Outer Diameter 10.0 mm In distribution
PS11.5-65SJ250 Outer Diameter 11.5 mm In distribution
PS13.0-80X265 Outer Diameter 13.0 mm In distribution
PS13.0-65X250 Outer Diameter 13.0 mm In distribution
SST-010-010 Outer Diameter 10.0 mm In distribution
PS13.0-65B250 Outer Diameter 13.0 mm In distribution
PS10.0-50C235 Outer Diameter 10 mm In distribution
PS13.0-50B235 Outer Diameter 13.0 mm In distribution
PS10.0-80X365 Outer Diameter 10.0 mm In distribution
PS10.0-65E250 Circumference 10.0 mm In distribution
PS13.0-65V250 Outer Diameter 13.0 mm In distribution
PS11.5-80A265 Outer Diameter 11.5 mm In distribution
PS13.0-80D265 Outer Diameter 13.0 mm In distribution
PS11.5-80A280 Outer Diameter 11.5 mm In distribution
PS11.5-65B250 Outer Diameter 11.5 mm In distribution
SST-010-015 Outer Diameter 10.0 mm In distribution
PS10.0-80C365 Outer Diameter 10.0 mm In distribution
PS11.5-80SJ305 Outer Diameter 11.5 mm In distribution
PS11.5-80C335 Outer Diameter 11.5 mm In distribution
PS10.0-80B265 Outer Diameter 10.0 mm In distribution
PS13.0-80E265 Outer Diameter 13.0 mm In distribution
PS10.0-80SJ335 Outer Diameter 10.0 mm In distribution
PS13.0-80A365 Outer Diameter 13.0 mm In distribution
PS13.0-80C305 Outer Diameter 13.0 mm In distribution
PS10.0-50D235 Outer Diameter 10 mm In distribution
PS10.0-50A235 Outer Diameter 10.0 mm In distribution
SST-013-005 Outer Diameter 13.0 mm In distribution
PS10.0-80B365 Outer Diameter 10.0 mm In distribution
PS13.0-80X335 Outer Diameter 13.0 mm In distribution
PS11.5-65C250 Outer Diameter 11.5 mm In distribution
PS10.0-50E235 Outer Diameter 10 mm In distribution
PS13.0-80A265 Outer Diameter 13.0 mm In distribution
PS13.0-50D235 Outer Diameter 13.0 mm In distribution
PS11.5-80X365 Outer Diameter 11.5 mm In distribution
PS13.0-80E305 Outer Diameter 13.0 mm In distribution
PS11.5-65A250 Outer Diameter 11.5 mm In distribution
PS10.0-80V265 Outer Diameter 10.0 mm In distribution
PS13.0-80SJ365 Outer Diameter 13.0 mm In distribution
PS10.0-80C305 Outer Diameter 10.0 mm In distribution
PS11.5-80V265 Outer Diameter 11.5 mm In distribution
PS10.0-80B335 Outer Diameter 10.0 mm In distribution
PS11.5-80C280 Outer Diameter 11.5 mm In distribution
PS13.0-80X305 Outer Diameter 13.0 mm In distribution
PS10.0-80D305 Outer Diameter 10.0 mm In distribution
PS11.5-80V305 Outer Diameter 11.5 mm In distribution
PS13.0-80B335 Outer Diameter 13.0 mm In distribution
PS10.0-65B250 Outer Diameter 11.5 mm In distribution
PS11.5-80A335 Outer Diameter 11.5 mm In distribution
PS10.0-80SJ305 Outer Diameter 10.0 mm In distribution
PS13.0-80A335 Outer Diameter 13.0 mm In distribution
PS10.0-65SJ250 Outer Diameter 10.0 mm In distribution
PS11.5-80B280 Outer Diameter 11.5 mm In distribution
PS10.0-50SJ235 Outer Diameter 10 mm In distribution
PS11.5-80SJ365 Outer Diameter 11.5 mm In distribution
PS11.5-80SJ280 Outer Diameter 11.5 mm In distribution
PS13.0-80B305 Outer Diameter 13.0 mm In distribution
PS10.0-80E335 Outer Diameter 10.0 mm In distribution
PS13.0-80SJ305 Outer Diameter 13.0 mm In distribution
PS10.0-80E365 Outer Diameter 10.0 mm In distribution
PS13.0-50E235 Outer Diameter 13.0 mm In distribution
PS10.0-80X305 Outer Diameter 10.0 mm In distribution
PS11.5-80B335 Outer Diameter 11.5 mm In distribution
SST-010-020 Outer Diameter 10.0 mm In distribution
PS10.0-80A335 Outer Diameter 10.0 mm In distribution
PS11.5-65E250 Outer Diameter 11.5 mm In distribution
PS11.5-80E365 Outer Diameter 11.5 mm In distribution
PS13.0-50V235 Outer Diameter 13.0 mm In distribution
PS11.5-50C235 Outer Diameter 11.5 mm In distribution
PS13.0-80D305 Outer Diameter 13.0 mm In distribution
PS11.5-80A365 Outer Diameter 11.5 mm In distribution
PS10.0-80A265 Outer Diameter 10.0 mm In distribution
PS13.0-50SJ235 Outer Diameter 13.0 mm In distribution
PS10.0-50B235 Outer Diameter 10 mm In distribution
PS11.5-80V365 Outer Diameter 11.5 mm In distribution
PS10.0-80D335 Outer Diameter 10.0 mm In distribution
PS11.5-80E335 Outer Diameter 11.5 mm In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
T2 Stryker GmbH 1,373
Autobahn Globus Medical, Inc. 1,258
Gamma Stryker GmbH 1,120
Summa Orthopaedics Femur Nail System Jeil Medical Corporation 742
Arix Femur Nail System Jeil Medical Corporation 742
Orthofix Orthofix SRL 721
Rod, Fixation, Intramedullary And Accessories Synthes Gmbh 715
Trigen Smith & Nephew, Inc. 681
Arthrex® Arthrex, Inc. 665
Precice® Intramedullary Limb Lengthening System NuVasive Specialized Orthopedics, Inc. 596
Apex Orthoxel Designated Activity Company 569
Natural Nail® Zimmer, Inc. 552

Showing 12 of 2,207. All products under Rod, Fixation, Intramedullary And Accessories

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K261651 2026-06-18
K232267 2023-12-15
K230765 2023-08-29
K220234 2023-03-15
K202348 2020-12-22
K200430 2020-09-16
K201567 2020-08-10
K193617 2020-05-08
K193016 2020-05-08
K191336 2019-09-26
K182170 2019-02-05
K180503 2018-04-03
K173129 2017-12-01
K172628 2017-09-25
K172061 2017-08-24
K170169 2017-06-09
K162927 2017-04-06
K170346 2017-03-07

Recalls Naming This Product

1 recall names this product by its own identifier, the 510(k) it is cleared under.

Recalls naming the identifiers of Precice® Stryde System
Recalled by Identified by Initiated FDA class Root cause Reason Quantity
NuVasive Specialized Orthopedics, Inc. 510(k) number 2021-02-12 Class II Under Investigation by firm Due to complaints of adverse events potentially related to biological safety. The complaints included report of pain and bony abnormalities at the interface between the telescoping nail segments. 2360 units

Recalls

8 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity
2024-09-30 Class II Under Investigation by firm Due to potential issues with design, manufacturing and documentation issues related to the validation of the affected products/devices. 164 devices
2021-10-29 Class II Device Design The Instructions for Use have been updated to include:
(1) Clarification that the device is intended for use only in patients 18 years and older,
(2) That patients should weigh 50 lbs. or more while undergoing treatment, and
(3) That no
Total 11,861 devices (IMLL=10,657 and Short=1,204)
2021-02-12 Class II Under Investigation by firm Due to complaints of adverse events potentially related to biological safety. The complaints included report of pain and bony abnormalities at the interface between the telescoping nail segments. 40 units
2021-02-12 Class II Under Investigation by firm Due to complaints of adverse events potentially related to biological safety. The complaints included report of pain and bony abnormalities at the interface between the telescoping nail segments. 226 units
2021-02-12 Class II Device Design Due to not having the full complement of biological assessments for all potential patients and as a result the devices are not indicated for use in individuals under the age of 18 years old. 59 units
2021-02-12 Class II Device Design Due to not having the full complement of biological assessments for all potential patients and as a result the devices are not indicated for use in individuals under the age of 18 years old. 10,657 units
2021-02-12 Class II Device Design Due to not having the full complement of biological assessments for all potential patients and as a result the devices are not indicated for use in individuals under the age of 18 years old. 229 units
2020-07-24 Class II Device Design During explantation, standard removal tools can generate sufficient forces to cause distal plug to disassociate from the bone transport system. 41 total units

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer