Trigen MAX

Trigen MAX Pinnable Flexible Entry Tube Sleeve

Registry build 21.09.26
17manufacturers in China registered for this device type
9catalogue numbers in this listing
11510(k) clearances naming this product code
12recalls on this code

Who Else Makes It

Concentrated in Jiangsu (7), Shanghai (3), Zhejiang (3). 10 of them are registered as contract manufacturers, able to build to a buyer’s own specification.

Chinese manufacturers registered for FDA product code HSB
Manufacturer City Province Registered as Device types
Zhejiang Biomet Medical Products Co., Ltd. Jinhua Zhejiang Contract manufacturer 74
Apex (Guangzhou) Tools & Orthopedics Company Guangzhou Guangdong Contract manufacturer 62
Changzhou Biomet Medical Devices Co., Ltd. Changzhou Jiangsu Contract manufacturer 54
Paragon Medical Device (Changzhou) Co., Ltd. Changzhou Jiangsu Contract manufacturer 53
Canwell Medical Co., Ltd. Jinhua Zhejiang Contract manufacturer 42
LX Precision Shanghai Co Ltd Shanghai Shanghai Contract manufacturer 19
Stryker (Suzhou) Medical Technology Co., Ltd. Suzhou Jiangsu Contract manufacturer 19
Suzhou Ahno Medical Devices Co., Ltd. Suzhou Jiangsu Contract manufacturer 17
Turnxon Precision Co., Ltd. Dongguan Guangdong Contract manufacturer 17
Suzhou Kangli Orthopaedics Instrument Co., Ltd. Zhangjiagang Jiangsu Contract manufacturer 11
Zimmer (Shanghai) Medical International Trading Co., Ltd. Shanghai Shanghai Exporter 106
Shanghai JPY ION-Tech Co., Ltd. Shanghai Shanghai Contract manufacturer 70

Showing 12 of 17. All 17 manufacturers in China registered for Rod, Fixation, Intramedullary And Accessories

Record

Regulatory record for Trigen MAX
Listed by Smith & Nephew, Inc., United States
FDA product code HSB
Device type Rod, Fixation, Intramedullary And Accessories
Device class Class 2
Regulation 21 CFR 888.3020
Establishment Contract manufacturer, Remanufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter
510(k) K240061
Record published 2025-05-07
Record revised 2026-03-19 (version 2)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Sterilisation Moist Heat or Steam Sterilization
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Label carries lot or batch number, expiry date
Storage Special storage condition: : –

Catalogue Numbers

Catalogue numbers for Trigen MAX
Catalogue number Size Status
72502040B Left: Left In distribution
72800123 In distribution
72502037 Semi-Extended: Semi-Extended In distribution
72800122 In distribution
72502040A Right: Right In distribution
72502038 Standard: Standard In distribution
72502036 Length: Semi-Extended In distribution
72502039 Standard: Standard In distribution
72502003 In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
T2 Stryker GmbH 1,373
Autobahn Globus Medical, Inc. 1,258
Gamma Stryker GmbH 1,120
Summa Orthopaedics Femur Nail System Jeil Medical Corporation 742
Arix Femur Nail System Jeil Medical Corporation 742
Orthofix Orthofix SRL 721
Rod, Fixation, Intramedullary And Accessories Synthes Gmbh 715
Trigen Smith & Nephew, Inc. 681
Arthrex® Arthrex, Inc. 665
Precice® Intramedullary Limb Lengthening System NuVasive Specialized Orthopedics, Inc. 596
Apex Orthoxel Designated Activity Company 569
Natural Nail® Zimmer, Inc. 552

Showing 12 of 2,207. All products under Rod, Fixation, Intramedullary And Accessories

510(K) Clearances

FDA 510(k) clearances naming this product code
Clearance Decision date
K243364 2024-12-09
K210980 2022-11-14
K163653 2017-10-13
K161264 2016-11-23
K122170 2012-10-19
K111025 2011-07-01
K092748 2010-04-26
K043052 2004-11-24
K040929 2004-05-25
K040462 2004-03-23
K032722 2003-10-01

Recalls

5 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2026-03-16 Class II Process control Humeral nail due to a manufacturing error is missing distal holes and if implanted may lead to revision surgery but, if the missing holes are identified before implantation, an equivalent backup can be used, or a bent nail of the same size, 5
2025-03-18 Class II Process control Integrated Lag/Compression Screw Kit has a compression screw with hexagon socket that may be undersized, which causes the screw to be non-functional, which would require replacement with another adequate size screw, and exchange may exceed 75
2023-07-24 Class II Process control A complaint was received indicating that a package contained a TRIGEN TROCHANTERIC ANTEGRADE NAIL LIME 11.5MM X 40CM 130 DEGREE LEFT implant instead of a TRIGEN TROCHANTERIC ANTEGRADE NAIL LIME 11.5MM X 36CM 130 DEGREE LEFT as described on 32 units
2023-07-24 Class II Process control A complaint was received indicating that a package contained a TRIGEN TROCHANTERIC ANTEGRADE NAIL LIME 11.5MM X 40CM 130 DEGREE LEFT implant instead of a TRIGEN TROCHANTERIC ANTEGRADE NAIL LIME 11.5MM X 36CM 130 DEGREE LEFT as described on 30 units
2013-03-06 Class II Process control One batch of 4.5 mm diameter Trigen Low-Profile Bone Screws were incorrectly anodized with a gold coating (indicating a 5 mm diameter) instead of a gray coating (indicating a 4.5 mm diameter). 23 units 2019-08-16
2008-04-22 Not classified Process control One of the distal locking screw holes on a hindfoot fusion nail was drilled with an incorrect trajectory. 114 2010-05-28
2008-04-22 Not classified Process control One of the distal locking screw holes on a hindfoot fusion nail was drilled with an incorrect trajectory. 40 2010-05-28
2008-04-22 Not classified Process control One of the distal locking screw holes on a hindfoot fusion nail was drilled with an incorrect trajectory. 34 2010-05-28
2008-04-22 Not classified Process control One of the distal locking screw holes on a hindfoot fusion nail was drilled with an incorrect trajectory. 45 2010-05-28
2008-04-22 Not classified Process control One of the distal locking screw holes on a hindfoot fusion nail was drilled with an incorrect trajectory. 8 2010-05-28
2008-04-22 Not classified Process control One of the distal locking screw holes on a hindfoot fusion nail was drilled with an incorrect trajectory. 16 2010-05-28
2008-04-22 Not classified Process control One of the distal locking screw holes on a hindfoot fusion nail was drilled with an incorrect trajectory. 8 2010-05-28

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer