Infinity™ Adaptis™

Tibial Tray

Registry build 21.09.26
1manufacturer
15catalogue numbers in this listing
9recalls on this code

Who Else Makes It

Registered in Jiangsu. One is registered as a contract manufacturer, able to build to a specification.

Chinese manufacturers registered for FDA product code HSN
Manufacturer City Province Registered as Device types
Stryker Orthmed (Changzhou) Medical Instrument Co., Ltd. Changzhou Jiangsu Contract manufacturer 10

Record

Regulatory record for Infinity™ Adaptis™
Listed by Wright Medical Technology, Inc., United States
FDA product code HSN
Device type Prosthesis, Ankle, Semi-Constrained, Cemented, Metal/Polymer
Device class Class 2
Regulation 21 CFR 888.3110
Establishment Contract manufacturer, Specification developer, Repacker / relabeller, Complaint-file establishment, Manufacturer, Exporter
510(k) K123954
Record published 2020-04-14
Record revised 2023-01-20 (version 3)

Specifications

Specifications
MRI safety Labeling does not contain MRI Safety Information
Sterilisation Moist Heat or Steam Sterilization
Supplied sterile Yes
Single use Yes
Prescription Prescription only
Latex Labelled latex-free
Label carries lot or batch number, expiry date, manufacturing date

Catalogue Numbers

Catalogue numbers for Infinity™ Adaptis™
Catalogue number Size Status
33680071 Size 1 In distribution
33680072 Size 2 In distribution
33680143 In distribution
33680004 Size: 4 In distribution
33680001 Size: 1 In distribution
33680005 Size: 5 In distribution
33680073 Size 3 In distribution
33680015 5 Long In distribution
33680003 Size: 3 In distribution
33680013 3 Long In distribution
33680014 4 Long In distribution
33680075 Flat Cut In distribution
9914PK02 SZ 4-6 In distribution
9914PK02 SZ 1-3 In distribution
33680074 Flat Cut In distribution

Same Product Code

Other products under the same FDA product code
Product Sold by Catalogue numbers
Apex 3D Total Ankle Replacement System Paragon 28 658
Vantage Exactech, Inc. 362
Cadence™ Ascension Orthopedics, Inc. 248
Cadence Total Ankle System Smith & Nephew, Inc. 246
Inbone Wright Medical Technology, Inc. 236
Hintermann Series H2 DT Medtech LLC 225
Infinity Wright Medical Technology, Inc. 220
Incompass Total Ankle System Wright Medical Technology, Inc. 213
Invision Wright Medical Technology, Inc. 186
Kinos Axiom Instrumentation restor3d, inc. 169
Quantum In2Bones SAS 157
Hintermann Series H2 Vilex LLC 153

Showing 12 of 53. All products under Prosthesis, Ankle, Semi-Constrained, Cemented, Metal/Polymer

Recalls Naming This Product

2 recalls name this product by its own identifiers, the 510(k) it is cleared under.

Recalls naming the identifiers of Infinity™ Adaptis™
Recalled by Identified by Initiated FDA class Root cause Reason Quantity
Wright Medical Technology, Inc. 510(k) number 2024-03-06 Class II Process change control Stryker has identified an issue that impacts specific lots of Infinity” Resection Guide Adjustment Blocks. The parts within these three lots were found to have been missing an internal screw in the finished instrument assembly. The missing 47 units
Wright Medical Technology, Inc. 510(k) number 2023-06-13 Class II Process control The devices were manufactured with the pin sleeve holes too narrow, which does not allow the pin sleeves to pass through the pin sleeve holes, thereby preventing pin placement through the pin holes. 106 devices

Recalls

7 of these are Class II. Class II means a temporary or reversible health consequence. Volume alone is not a quality signal: a manufacturer that ships more recalls more.

Recalls referencing this product code
Initiated FDA class Root cause Reason Quantity Closed
2022-09-30 Class II Device Design The tibial tray lock detail is oversized (larger than specification). 1 unit 2026-08-21
2022-09-30 Class II Device Design The tibial tray lock detail is oversized (larger than specification). 1 unit 2026-08-21
2022-06-02 Class II Nonconforming Material/Component The instrument is incorrectly color coded. 35 units
2021-11-04 Class II Nonconforming Material/Component The package contents and package labeling do not match. 2 units 2023-01-06
2021-11-04 Class II Nonconforming Material/Component The package contents and package labeling do not match. 0 (2 Quarantined) 2023-01-06
2020-04-09 Class II Nonconforming Material/Component One lot of INBONE Tibial Trays is missing the plasma coating. 22 units 2020-11-02
2016-11-08 Class II Process control The firm discovered a lack of adequate documentation confirming sterility on certain products. 65 units 2020-11-03

Source: U.S. FDA establishment registration and device listing records, public domain. Restructured for clarity and searchability. Not affiliated with or endorsed by the FDA. Records are records: nothing here is an offer of sale.

Where China Actually Supplies

Every device page names the company that lists it and the factories registered to make the same thing. These are the sections with the most of them.

5,100manufacturers registered in China
2,581device types they are registered for
340,248device records, each naming its maker
31provinces with a registered manufacturer